A comparison of clinical outcomes and optical performance between monofocal and new monofocal with enhanced intermediate function intraocular lenses: a case-control study.
Huh, Jungah; Eom, Youngsub; Yang, Seul Ki; Choi, Young; Kim, Hyo Myung; Song, Jong Suk.
Afiliação
  • Huh J; Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea.
  • Eom Y; Department of Ophthalmology, Korea University Guro Hospital, 148 Gurodong-ro, Guro-gu, Seoul, 08308, South Korea.
  • Yang SK; Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea.
  • Choi Y; Department of Ophthalmology, Korea University Ansan Hospital, Ansan-si, Gyeonggi-do, Republic of Korea.
  • Kim HM; Space Optics Laboratory, Department of Astronomy, Yonsei University, Seoul, Republic of Korea.
  • Song JS; Satellite system 2 Team, Hanwha Systems Co., Ltd., Yongin-si, Gyeonggi-do, Republic of Korea.
BMC Ophthalmol ; 21(1): 365, 2021 Oct 16.
Article em En | MEDLINE | ID: mdl-34656091
ABSTRACT

BACKGROUND:

To compare clinical outcomes and optical performance of a new monofocal with enhanced intermediate function intraocular lenses (IOLs) with that of conventional monofocal IOLs.

METHODS:

Sixty eyes of 30 patients who underwent phacoemulsification with bilateral implantation of the ICB00 (15 patients) or ZCB00 (15 patients) IOLs were enrolled. Binocular corrected distance visual acuity (CDVA), distance corrected near visual acuity (DCNVA), and distance corrected intermediate visual acuity (DCIVA) were measured at 4 weeks after surgery. Patient satisfaction for overall, near, intermediate, and distance vision were assessed. The binocular defocus curves were measured. The root mean square of modulation transfer function (MTFRMS) was measured in the optical bench study.

RESULTS:

The mean binocular DCIVA was significantly better in the ICB00 group (0.01 logMAR) compared to the ZCB00 group (0.13 logMAR), but CDVA and DCNVA were not. The patient satisfaction for near and intermediate vision was significantly higher in the ICB00 group compared to the ZCB00. However, there was no difference in patient satisfaction for overall and distance vision between two groups. The defocus curves showed that mean visual acuity of the ICB00 group was significantly better than that of the ZCB00 group at between - 1.00 D to - 3.00 D of defocus. The ICB00 IOL had higher MTFRMS values at between - 0.50 D to - 2.00 D of defocus compared to the ZCB00 IOL.

CONCLUSIONS:

The ICB00 IOL provides better binocular intermediate vision and higher satisfaction for near and intermediate vision than the ZCB00 IOL while maintaining excellent distance vision.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: BMC Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2021 Tipo de documento: Article