Your browser doesn't support javascript.
loading
MXene-assisted organic electrochemical transistor biosensor with multiple spiral interdigitated electrodes for sensitive quantification of fPSA/tPSA.
Zhu, Yi-Cheng; Cai, Biao; Jiang, Quan; Zhang, Yuan; Sha, Jianjun; Xie, Shaowei.
Afiliação
  • Zhu YC; Department of Ultrasound, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, 201200, China.
  • Cai B; Department of Urology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China.
  • Jiang Q; Department of Ultrasound, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, 201200, China.
  • Zhang Y; Department of Ultrasound, Pudong New Area People's Hospital Affiliated to Shanghai University of Medicine and Health Sciences, Shanghai, 201200, China.
  • Sha J; Department of Urology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China. shajianjunuro@163.com.
  • Xie S; Department of Ultrasound, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, China. xieshaowei@renji.com.
J Nanobiotechnology ; 19(1): 386, 2021 Nov 24.
Article em En | MEDLINE | ID: mdl-34819078
BACKGROUND: The ratio of fPSA/tPSA in the "grey zone" of tPSA with the concentration range between 4 ng/ml and 10 ng/ml is significant for diagnosis of prostate cancer, and highly efficiency quantification of the ratio of fPSA/tPSA remain elusive mainly because of their extremely low concentration in patients' peripheral blood with high biosample complexity. METHODS: We presented an interdigitated spiral-based MXene-assisted organic electrochemical transistors (isMOECTs) biosensor for highly sensitive determination of fPSA/tPSA. The combination of MXene and the interdigitated multiple spiral architecture synergistically assisted the amplification of amperometric signal of biosensor with dual functionalizations of anti-tPSA and anti-fPSA. RESULTS: The ultrasensitivity of the biosensor was enhanced by tunable multiple spiral architecture and MXene nanomaterials; and the sensor exhibited improved detection limit of tPSA and fPSA down to 0.01 pg/ml and acceptable performance of selectivity, repeatability and stability. Moreover, the isMOECTs displayed area under the curve (AUC) value of 0.8138, confirming the potential applications of isMOECTs in clinics. CONCLUSIONS: The merits of isMOECTs biosensor demonstrated the reliability of MXene-assisted organic electrochemical transistor biosensor with multiple interdigitated spiral for ultrasensitive quantification of fPSA/tPSA, suggesting potential current and future point-of-care testing applications.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Antígeno Prostático Específico / Técnicas Eletroquímicas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans / Male Idioma: En Revista: J Nanobiotechnology Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Antígeno Prostático Específico / Técnicas Eletroquímicas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans / Male Idioma: En Revista: J Nanobiotechnology Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China