Topographic, tomographic, and corneal wavefront asymmetry in keratoconus: towards an eye asymmetry index EASIX.
Mehlan, Juliane; Steinberg, Johannes; Druchkiv, Vasyl; Katz, Toam; Linke, Stephan Johannes.
Afiliação
  • Mehlan J; Department of Ophthalmology, University Medical Center Hamburg-Eppendorf (UKE), Martinistrasse 52, 20246, Hamburg, Germany. julianemehlan@gmail.com.
  • Steinberg J; CARE Vision/Clinica Baviera, Hamburg, Germany.
  • Druchkiv V; Zentrumsehstärke, Martinistr. 64, 20251, Hamburg, Germany.
  • Katz T; Department of Ophthalmology, University Medical Center Hamburg-Eppendorf (UKE), Martinistrasse 52, 20246, Hamburg, Germany.
  • Linke SJ; Department of Ophthalmology, University Medical Center Hamburg-Eppendorf (UKE), Martinistrasse 52, 20246, Hamburg, Germany.
Graefes Arch Clin Exp Ophthalmol ; 260(9): 2949-2958, 2022 Sep.
Article em En | MEDLINE | ID: mdl-35396961
ABSTRACT

PURPOSE:

The study aims to explore the intereye asymmetry in normal and keratoconic individuals and to evaluate the discriminant power of single and combined asymmetry parameters.

METHODS:

This is a retrospective designed study including 414 patients who had Pentacam Scheimpflug topographic and tomographic imaging in both eyes 124 subjects with bilateral normal corneas evaluated for refractive surgery and 290 with keratoconus. All elevation-, pachymetric-, and volumetric-based data (56 parameters) were electronically retrieved and analyzed. Intereye asymmetry was determined by subtracting the lowest value from the highest value for each variable. The degree of asymmetry between each subject's eyes was calculated with intraclass correlation coefficients for all the parameters. Receiver operating characteristic curve was used to determine predictive accuracy and to identify optimal cutoffs of these values and combinations thereof.

RESULTS:

In the normal/keratoconus subjects the median intereye asymmetries were 0.30/3.45 for K2 (flat) meridian, 0.03/0.25 for BFS front, 1.00/15.00 for elevation back BFS apex, and 7.00/29.00 for pachy min.

CONCLUSIONS:

In addition to Rabinowitz's Kmax intereye asymmetry we propose pachymetric, elevation-based, and high-order corneal wavefront intereye asymmetry parameters to improve the diagnostic armamentarium of keratoconus.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Ceratocone Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Ceratocone Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Alemanha