Toxicity of bioceramic and resinous endodontic sealers using an alternative animal model: Artemia salina.
Malta, Cristiana Pereira; Silva Barcelos, Raquel Cristine; Segat, Hecson Jesser; Burger, Marilise Escobar; Souza Bier, Carlos Alexandre; Morgental, Renata Dornelles.
Afiliação
  • Malta CP; Department of Stomatology, School of Dentistry, Federal University of Santa Maria, Santa Maria, Brazil.
  • Silva Barcelos RC; Department of Stomatology, School of Dentistry, Federal University of Santa Maria, Santa Maria, Brazil.
  • Segat HJ; Department of Stomatology, School of Dentistry, Federal University of Santa Maria, Santa Maria, Brazil.
  • Burger ME; Department of Stomatology, School of Dentistry, Federal University of Santa Maria, Santa Maria, Brazil.
  • Souza Bier CA; Department of Stomatology, School of Dentistry, Federal University of Santa Maria, Santa Maria, Brazil.
  • Morgental RD; Department of Stomatology, School of Dentistry, Federal University of Santa Maria, Santa Maria, Brazil.
J Conserv Dent ; 25(2): 185-188, 2022.
Article em En | MEDLINE | ID: mdl-35720815
ABSTRACT

Aims:

The present study assessed the toxicity of a novel calcium silicate-based root canal sealer (Bio-C Sealer) in comparison to Endosequence BC Sealer and AH Plus through a lethality assay involving brine shrimp (Artemia salina).

Methods:

Brine shrimp cysts were incubated for 24 h for the hatching of the larvae, which were then exposed to different concentrations (2.5, 5, 10, 20, 40, 80, and 100 µg/mL) of the test endodontic sealers for 24 h, followed by the determination of the survival rate. Statistical Analysis Used One-way repeated-measures ANOVA and the Newman-Keuls post hoc test were used to compare the different materials as well as different concentrations of the same material. Dunnett's test was used to compare the different concentrations and different sealers to the control. The lethal concentration of each endodontic sealer necessary to kill 50% of the brine shrimp larvae (LC50) was also determined.

Results:

The toxicity of Bio-C (10, 20, 40, 80, and 100 µg/mL) and Endosequence BC Sealer (20, 80, and 100 µg/mL) was lower than that of AH Plus. No significant difference was found between Bio-C and Endosequence BC Sealer or among the different intragroup concentrations of these sealers. In the AH Plus group, concentrations ≥5.0 µg/mL exhibited greater toxicity compared to the concentration of 2.5 µg/mL and the control. AH Plus had the lowest LC50 (59.95 µg/mL), whereas Bio-C and Endosequence BC Sealer had LC50 values >200 µg/mL.

Conclusions:

Bio-C Sealer proved to be less toxic than AH Plus and exhibited similar toxicity to that of Endosequence BC Sealer.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Idioma: En Revista: J Conserv Dent Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil