Your browser doesn't support javascript.
loading
Assessment of the influence of keratometry on intraocular lens calculation formulas in long axial length eyes.
Yin, Shengjie; Guo, Chengyao; Qiu, Kunliang; Ng, Tsz Kin; Li, Yuancun; Du, Yali; Chen, Bingyao; Wang, Hongxi; Zhang, Mingzhi.
Afiliação
  • Yin S; Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China.
  • Guo C; Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China.
  • Qiu K; Shantou University Medical College, Shantou, Guangdong, China.
  • Ng TK; Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China.
  • Li Y; Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China.
  • Du Y; Shantou University Medical College, Shantou, Guangdong, China.
  • Chen B; Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Shatin, Hong Kong.
  • Wang H; Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, North Dongxia Road, Shantou, 515041, Guangdong, China.
  • Zhang M; Shantou University Medical College, Shantou, Guangdong, China.
Int Ophthalmol ; 42(10): 3211-3219, 2022 Oct.
Article em En | MEDLINE | ID: mdl-36057757
ABSTRACT

PURPOSE:

Hyperopic surprises tend to occur in axial myopic eyes and other factors including corneal curvature have rarely been analyzed in cataract surgery, especially in eyes with long axial length (≥ 26.0 mm). Thus, the purpose of our study was to evaluate the influence of keratometry on four different formulas (SRK/T, Barrett Universal II, Haigis and Olsen) in intraocular lens (IOL) power calculation for long eyes.

METHODS:

Retrospective case series. A total of 180 eyes with axial length (AL) ≥ 26.0 mm were divided into 3 keratometry (K) groups K ≤ 42.0 D (Flat), K ≥ 46.0 D (Steep), 42.0 < K < 46.0 D (Average), and all the eyes were underwent phacoemulsification cataract surgery with Rayner (Hove, UK) 920H IOL implantation. Prediction errors (PE) were compared between different formulas to assess the accuracy of different formulas. Multiple regression analysis was performed to investigate factors associated with the PE.

RESULTS:

The mean absolute error was higher for all evaluated formulas in Steep group (ranging from 0.66 D to 1.02 D) than the Flat (0.34 D to 0.67 D) and Average groups (0.40 D to 0.74D). The median absolute errors predicted by Olsen formula were significantly lower than that predicted by Haigis formula (0.42 D versus 0.85 D in Steep and 0.29 D versus 0.69 D in Average) in Steep and Average groups (P = 0.012, P < 0.001, respectively). And the Olsen formula demonstrated equal accuracy to the Barrett II formula in Flat and Average groups. The predictability of the SRK/T formula was affected by the AL and K, while the predictability of Olsen and Haigis formulas was affected by the AL only.

CONCLUSIONS:

Steep cornea has more influence on the accuracy of IOL power calculation than the other corneal shape in long eyes. Overall, both the Olsen and Barrett Universal II formulas are recommended in long eyes with unusual keratometry.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Catarata / Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Int Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Catarata / Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Int Ophthalmol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China