Your browser doesn't support javascript.
loading
Longitudinal evaluation of trifocal and extended depth of focus lenses implantation using standard automated perimetry parameters.
Abe, Ricardo Yuji; da Silva, Maíra Gomes Barbosa; Alves, Thiago Nogueira; Tzelikis, Patrick Frensel de M; Hida, Wilson Takashi.
Afiliação
  • Abe RY; Hospital Oftalmológico de Brasília, Avenida L2 Sul, SGAS 607, Brasília, DF, 70200670, Brazil. ricardoabe85@yahoo.com.br.
  • da Silva MGB; Hospital Oftalmológico de Brasília, Avenida L2 Sul, SGAS 607, Brasília, DF, 70200670, Brazil.
  • Alves TN; Hospital Oftalmológico de Brasília, Avenida L2 Sul, SGAS 607, Brasília, DF, 70200670, Brazil.
  • Tzelikis PFM; Hospital Oftalmológico de Brasília, Avenida L2 Sul, SGAS 607, Brasília, DF, 70200670, Brazil.
  • Hida WT; Hospital Oftalmológico de Brasília, Avenida L2 Sul, SGAS 607, Brasília, DF, 70200670, Brazil.
Int Ophthalmol ; 43(4): 1285-1289, 2023 Apr.
Article em En | MEDLINE | ID: mdl-36127503
PURPOSE: To evaluate reliability and global indices parameters from standard automated perimetry (SAP) in normal eyes undergoing phacoemulsification cataract surgery with implantation of trifocal or extended depth of focus intraocular lens (IOL). METHODS: Prospective study to evaluate the effect of trifocal IOL AcrySof IQ PanOptix® and extended depth of focus intraocular lens (EDOF) Tecnis Symfony® IOL implantation on visual field parameters. Patients underwent SAP pre- and postoperatively. Reliability indices (false negative rate-FN, false positive rate-FP), global indices (foveal sensitivity threshold, visual field index-VFI, standard pattern deviation-PSD, mean deviation MD) and test duration were analyzed. RESULTS: A total of 23 eyes from 13 patients were in the trifocal IOL group and a total of 22 eyes from 14 patients were in the EDOF group. The following results were obtained by analyzing pre- and postoperative SAP of EDOF IOL: the rate of change of FN was 1.95/1.41% (p = 0.61); FP 1.64/1.27 (p = 0.60); MD - 1.60/- 1.08 dB (p = 0.15); foveal sensitivity was 34.5/33.9 dB (p = 0.41); VFI 98.5/98.4% (p > 0.99); PSD 1.85/1.86 (p = 0.07); and for test duration 305.81/298.36 s (p = 0.35); all respectively. Analysis of pre- and postoperative parameters of trifocal IOL were the rates of change of FN 1.22/1.83% (p = 0.29); FP 1.65/1.48% (p = 0.95); MD - 1.55/- 1.37 dB (p = 0.19); foveal sensitivity 33.9/34.9 dB (p = 0.47); VFI 98.6/98.3% (p = 0.62); PSD 1.58/2.05 (p = 0.02); and test duration 297.17/298.57 s (p = 0.87); all respectively. CONCLUSION: We identified a change in the PSD parameters in the trifocal IOL group. No other significant changes were identified in SAP parameters after implantation of trifocal AcrySof IQ PanOptix® and EDOF Tecnis Symfony® IOL. Longitudinal evaluation showed no changes in SAP after Trifocal and EDOF IOL implantation in normal subjects.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Int Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Facoemulsificação / Lentes Intraoculares Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Int Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil