Your browser doesn't support javascript.
loading
Detection of Synthetic Cannabinoid CUMYL-PEGACLONE in E-Cigarette Oil and Hair.
Jiao, Tai-Feng; Li, Ya-Qing; Kang, Gang; Chen, Shen-Shu; Cheng, Liang-Hong.
Afiliação
  • Jiao TF; Guangdong Nantian Institute of Forensic Science, Shenzhen 518003, Guangdong Province, China.
  • Li YQ; Guangdong Nantian Institute of Forensic Science, Shenzhen 518003, Guangdong Province, China.
  • Kang G; Guangdong Nantian Institute of Forensic Science, Shenzhen 518003, Guangdong Province, China.
  • Chen SS; Guangdong Nantian Institute of Forensic Science, Shenzhen 518003, Guangdong Province, China.
  • Cheng LH; Guangdong Nantian Institute of Forensic Science, Shenzhen 518003, Guangdong Province, China.
Fa Yi Xue Za Zhi ; 38(5): 595-600, 2022 Oct 25.
Article em En, Zh | MEDLINE | ID: mdl-36727175
OBJECTIVES: To establish a combined high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) method to detect the synthetic cannabinoid CUMYL-PEGACLONE in e-cigarette oil and hair. METHODS: HPLC-MS/MS and GC-MS were used to establish the detection method of CUMYL-PEGACLONE, and the hair of drug-involved persons and the seized e-cigarette oil were detected. RESULTS: The main mass spectrometry characteristic ions m/z of CUMYL-PEGACLONE measured by GC-MS were 91, 179, 197, 254 and 372. CUMYL-PEGACLONE had a good linear relationship in the mass concentration range of 2-50 ng/mL, and the linear correlation coefficient (r) was greater than 0.99. The limit of detection (LOD) of CUMYL-PEGACLONE in hair was 0.01 ng/mg, and the limit of quantitation (LOQ) was 0.02 ng/mg. The LOD of CUMYL-PEGACLONE in e-cigarette oil was 1 ng/mg, and the LOQ was 2 ng/mg. The average recoveries of CUMYL-PEGACLONE under the attempt at high, intermediate and low levels in blank human hair and e-cigarette oil matrix were 98.2%-132.4% and 93.5%-110.6%, and the intraday and intraday precision were 1.2%-12.9% and 0.7%-2.9%. CUMYL-PEGACLONE was detected in the hair of 15 drug-involved persons. Except for 1 person who was lower than LOQ, the concentration of CUMYL-PEGACLONE in the hair of other 14 persons was 0.035-0.563 ng/mg. The mass fraction of CUMYL-PEGACLONE in 2 e-cigarette oil were 0.17% and 0.21%, respectively. CONCLUSIONS: The established HPLC-MS/MS and GC-MS methods are applied to the detection of HPLC-MS/MS in drug-related cases, which provides strong evidence support for the handling authority to quickly investigate these cases, and also provides a reference for the identification of such substances in future.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Canabinoides / Drogas Ilícitas / Sistemas Eletrônicos de Liberação de Nicotina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En / Zh Revista: Fa Yi Xue Za Zhi Assunto da revista: JURISPRUDENCIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Canabinoides / Drogas Ilícitas / Sistemas Eletrônicos de Liberação de Nicotina Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En / Zh Revista: Fa Yi Xue Za Zhi Assunto da revista: JURISPRUDENCIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China