Your browser doesn't support javascript.
loading
Treatment of Refractory Congenital Pseudoarthrosis of Tibia with Contralateral Vascularized Fibular Bone Graft and Anatomic Distal Tibial Locking Plate: A Case Series and Literature Review.
Chou, Te-Feng Arthur; Liu, Ting-Yu; Wang, Matthew N; Yang, Chen-Yuan.
Afiliação
  • Chou TA; Department of Orthopaedics, Kuang Tien General Hospital, Taichung 433401, Taiwan.
  • Liu TY; Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei 112201, Taiwan.
  • Wang MN; Department of Orthopaedic Surgery, Montefiore Medical Center, Albert Einstein College of Medicine, The Bronx, NY 10461, USA.
  • Yang CY; Department of Orthopaedics, Kuang Tien General Hospital, Taichung 433401, Taiwan.
Children (Basel) ; 10(3)2023 Mar 03.
Article em En | MEDLINE | ID: mdl-36980061
ABSTRACT

BACKGROUND:

Congenital pseudoarthrosis of the tibia (CPT) remains a challenge for physicians. Several treatment options have been proposed, but the standard of care remains inconclusive. In this study, we present three patients for whom the failure of prior treatments was managed with a contralateral vascularized fibular bone graft (VFG) and an anatomic distal tibial locking plate.

METHODS:

Between 2017 and 2021, three patients were referred for failed treatment of CPT. All patients had undergone multiple prior surgeries, including tumor excision and fixation with ring external fixators, plates, and screws. We performed radical tumor resection and reconstruction of bone defects with a VFG. The construct was fixed with an anatomic locking plate, and the patients were followed up for a mean of 45.7 months.

RESULTS:

All three patients were able to obtain graft union at 19.3 weeks. At the final follow-up, all grafts achieved bony hypertrophy without evidence of bone resorption or local tumor recurrence. There was a mean leg length difference of 8.5 cm preoperatively, compared with 6.3 cm postoperatively. The average lower leg angulation was 7.4 degrees and the average ankle range of motion was 58.3 degrees. The mean VAS score was 0 and the mean AOFAS score was 88.3. No significant complications were noted.

CONCLUSIONS:

Implantation of a VFG and an anatomic distal tibia locking plate can be considered an option for treatment-refractory CPT. Patients can expect to achieve bone consolidation, ambulate as tolerated, and have a low complication rate.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Idioma: En Revista: Children (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Idioma: En Revista: Children (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Taiwan