Your browser doesn't support javascript.
loading
Toward Systematic Assessment and Improvement of Radiation Therapy Plan Quality of Cooperative Group Trial Submissions: A Report From the Children's Oncology Group.
Olch, Arthur J; Gopalakrishnan, Mahesh; Murphy, Erin S; MacDonald, Shannon M; Hua, Chia-Ho.
Afiliação
  • Olch AJ; Department of Radiation Oncology, University of Southern California and Children's Hospital Los Angeles, Los Angeles, California. Electronic address: aolch@chla.usc.edu.
  • Gopalakrishnan M; Department of Radiation Oncology, Northwestern Memorial Hospital, Chicago, Illinois.
  • Murphy ES; Department of Radiation Oncology, Cleveland Clinic, Cleveland, Ohio.
  • MacDonald SM; Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts.
  • Hua CH; Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, Tennessee.
Pract Radiat Oncol ; 13(4): e374-e382, 2023.
Article em En | MEDLINE | ID: mdl-37037758
ABSTRACT

PURPOSE:

This study evaluates the quality of plans used for the treatment of patients in the Children's Oncology Group study ACNS1123. Plan quality is quantified based on a scoring system specific to the protocol. In this way, the distribution of plan quality scores is determined that can be used to identify plan quality issues for this study and for future plan quality improvement. METHODS AND MATERIALS ACNS1123 stratum 1 patients (70) were evaluated. This included 50 photon and 20 proton plans. Digital Imaging and Communications in Medicine (DICOM) structure and dose data were obtained from the Children's Oncology Group. A commercially available plan quality scoring algorithm was used to create a scoring system we designed using the protocol dosimetric requirements. The whole ventricle and boost planning target volumes (PTVs) could earn a maximum of 70 points, whereas the organs at risk could earn 30 points (total maximum score of 100 points). The scoring algorithm adjusted scores based on the difficulty in achieving the structure dose requirements, which depended on the proximity of the PTVs and the dose gradients achieved relative to the organs at risk. The distribution of plan scores was used to determine the mean, median, and range of scores.

RESULTS:

The median adjusted plan quality scores for the 20 proton and 50 photon plans were 83.3 and 86.9, respectively. The range of adjusted scores (maximum to minimum) was 50 points. The average score adjustment was 7.4 points. Photon and proton plans performed almost equally. Average plan quality by individual structure revealed that the brain stem, PTV boost, and cochlea lost the most points.

CONCLUSIONS:

This report is the first to systematically analyze overall radiation therapy plan quality scores for an entire cohort of patients treated in a cooperative group clinical trial. The methodology demonstrated a large variation in plan quality in this trial. Future clinical trials could potentially use this method to reduce plan quality variability, which may improve outcomes.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Prevencao_e_fatores_de_risco / Agentes_cancerigenos / Tratamento / Radioterapia Base de dados: MEDLINE Assunto principal: Radioterapia de Intensidade Modulada / Terapia com Prótons Tipo de estudo: Etiology_studies / Guideline / Prognostic_studies Limite: Child / Humans Idioma: En Revista: Pract Radiat Oncol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Prevencao_e_fatores_de_risco / Agentes_cancerigenos / Tratamento / Radioterapia Base de dados: MEDLINE Assunto principal: Radioterapia de Intensidade Modulada / Terapia com Prótons Tipo de estudo: Etiology_studies / Guideline / Prognostic_studies Limite: Child / Humans Idioma: En Revista: Pract Radiat Oncol Ano de publicação: 2023 Tipo de documento: Article