Apically extruded debris, canal transportation, and shaping ability of nickel-titanium instruments on contracted endodontic cavities in molar teeth.
Zhang, Qinqin; Gu, Jingyi; Shen, Jiadi; Ma, Ming; Lv, Ying; Wei, Xin.
Afiliação
  • Zhang Q; Department of Endodontics, Affiliated Stomatological Hospital of Nanjing Medical University.
  • Gu J; Department of Endodontics, Affiliated Stomatological Hospital of Nanjing Medical University.
  • Shen J; Department of Endodontics, Affiliated Stomatological Hospital of Nanjing Medical University.
  • Ma M; Department of Endodontics, Affiliated Stomatological Hospital of Nanjing Medical University.
  • Lv Y; Department of Endodontics, Affiliated Stomatological Hospital of Nanjing Medical University.
  • Wei X; Department of Endodontics, Affiliated Stomatological Hospital of Nanjing Medical University.
J Oral Sci ; 65(4): 203-208, 2023 Oct 01.
Article em En | MEDLINE | ID: mdl-37532528
ABSTRACT

PURPOSE:

Apically extruded debris, canal transportation and shaping ability were compared between contracted endodontic cavities (CECs) and traditional endodontic cavities (TECs) after instrumentation with XP-endo Shaper (XPS), ProTaper Gold (PTG), ProTaper for hand-use (HPT) and Hero Shaper.

METHODS:

The CECs or TECs groups were sub-divided into 24 groups according to root canal morphology and nickel-titanium (Ni-Ti) instruments. The weight of apically extruded debris was calculated using the Myers and Montgomery model. Pre- and postoperative images of teeth were scanned using micro-CT and the three-dimensional models were constructed and compared.

RESULTS:

Under CECs or TECs, XPS and PTG produced less apical debris and formed less canal transportation than HPT and Hero Shaper (P < 0.05). XPS group under CECs extruded less apical debris than that under TCEs for round canals with curvature of 20°-35° (P < 0.05). The centering ratios of four tested instruments were higher under TECs than those under CECs (P < 0.05). The HPT and Hero Shaper had more transportation under CECs than that under TCEs (P < 0.05). No statistical difference was found regarding shaping ability among all the groups.

CONCLUSION:

Under CECs, XPS preserves the original root canal anatomy, meanwhile it produces less apical debris than the other instruments.