Your browser doesn't support javascript.
loading
Bicarbonate buffer dissolution test with gentle mechanistic stress for bioequivalence prediction of enteric-coated pellet formulations.
Ikuta, Shotaro; Nakagawa, Hidetoshi; Kai, Toshiya; Sugano, Kiyohiko.
Afiliação
  • Ikuta S; Molecular Pharmaceutics Lab., College of Pharmaceutical Sciences, Ritsumeikan University, 1-1-1, Noji-higashi, Kusatsu, Shiga 525-8577, Japan; Pharmaceutical Research Laboratories, Pharmaceutical Department, Nipro Corporation, 3023, Noji-Cho, Kusatsu, Shiga 525-0055, Japan. Electronic address: ikuta
  • Nakagawa H; Pharmaceutical Research Laboratories, Pharmaceutical Department, Nipro Corporation, 3023, Noji-Cho, Kusatsu, Shiga 525-0055, Japan.
  • Kai T; Pharmaceutical Research Laboratories, Pharmaceutical Department, Nipro Corporation, 3023, Noji-Cho, Kusatsu, Shiga 525-0055, Japan.
  • Sugano K; Molecular Pharmaceutics Lab., College of Pharmaceutical Sciences, Ritsumeikan University, 1-1-1, Noji-higashi, Kusatsu, Shiga 525-8577, Japan.
Eur J Pharm Sci ; 192: 106622, 2024 Jan 01.
Article em En | MEDLINE | ID: mdl-37884100
ABSTRACT
This study aimed to develop a dissolution test that can predict the bioequivalence (BE) of enteric-coated pellet formulations. The original duloxetine hydrochloride capsule (reference formulation (RF); Cymbalta® 30 mg capsule) and four generic test formulations (two capsules (CP) and two orally disintegrating tablets (OD)) were used as model formulations. Clinical BE studies were conducted on 24-47 healthy male subjects under fasting conditions. Dissolution tests were performed using a compendial paddle method (PD) (paddle speed 50 rpm) and a flow-through cell method (FTC) (flow rate 4 mL/min). For a further test, cotton balls were added to the vessel to apply gentle mechanistic stress to the formulations, and paddle speed was reduced to 10 rpm (paddle with cotton ball method (PDCB)).All the dissolution tests were conducted with 0.01 M HCl (pH 2.0) for 0.5 h followed by 10 mM bicarbonate buffer solutions (pH 6.5) for 4 h. One each of the two CP and two OD showed BE with RF. PDCB was able to discriminate between BE and non-BE formulations, while this was not possible with PD and FTC. In PDCB, the cotton balls intermittently moved the pellets near the vessel bottom. PDCB is useful for predicting BE during formulation development.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Bicarbonatos Limite: Humans / Male Idioma: En Revista: Eur J Pharm Sci Assunto da revista: FARMACIA / FARMACOLOGIA / QUIMICA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Bicarbonatos Limite: Humans / Male Idioma: En Revista: Eur J Pharm Sci Assunto da revista: FARMACIA / FARMACOLOGIA / QUIMICA Ano de publicação: 2024 Tipo de documento: Article