Risk of anastomotic leakage with two-row versus three-row manual circular staplers in colorectal anastomosis: a U.S. cohort study.
Wang, Tongtong; Sadowsky, Mordechai; Blakney, Rebekah; Coplan, Paul; Petraiuolo, William; Soberman, Mark; Tomaszewski, Joerg; Rene, Lexi; Wood, Jennifer.
Afiliação
  • Wang T; Epidemiology & Real-World Data Sciences, MedTech, Johnson & Johnson, New Brunswick, NJ, USA. TWang124@its.jnj.com.
  • Sadowsky M; Medical Safety, MedTech, Johnson & Johnson, New Brunswick, NJ, USA.
  • Blakney R; Epidemiology & Real-World Data Sciences, MedTech, Johnson & Johnson, New Brunswick, NJ, USA.
  • Coplan P; Epidemiology & Real-World Data Sciences, MedTech, Johnson & Johnson, New Brunswick, NJ, USA.
  • Petraiuolo W; Medical Safety, MedTech, Johnson & Johnson, New Brunswick, NJ, USA.
  • Soberman M; Medical Safety, MedTech, Johnson & Johnson, New Brunswick, NJ, USA.
  • Tomaszewski J; Medical Affairs, MedTech, Johnson & Johnson, Raritan, NJ, USA.
  • Rene L; Epidemiology & Real-World Data Sciences, MedTech, Johnson & Johnson, New Brunswick, NJ, USA.
  • Wood J; Epidemiology & Real-World Data Sciences, MedTech, Johnson & Johnson, New Brunswick, NJ, USA.
Int J Colorectal Dis ; 38(1): 264, 2023 Nov 07.
Article em En | MEDLINE | ID: mdl-37932486
PURPOSES: To compare the risk of anastomotic leak (AL) between Ethicon manual circular staplers (two-row) versus Medtronic EEA™ circular stapler with Tri-Staple™ technology (three-row) and between Medtronic EEA™ circular stapler with DST™ Series technology (two-row) versus Tri-Staple™ technology. METHODS: A retrospective cohort study was conducted in adult patients who underwent a left-sided colorectal surgery 2019-2022 in U.S. Premier Healthcare Database to assess the risk of AL within 30 days post-index procedure. The study devices were Ethicon manual circular staplers, Medtronic EEA™ circular stapler with DST™ technology, and Medtronic EEA™ circular stapler with Tri-Staple™ technology. RESULTS: Across 447 hospitals, the cumulative incidences (95% confidence intervals [CI]) of AL within 30 days post-index procedure were 7.78% (6.91-8.74%) among 8337 patients in the Ethicon manual circular stapler cohort, 7.54% (6.87-8.27%) among 7928 patients in the Medtronic EEA™ circular stapler with DST™ technology cohort, and 8.19% (6.57-10.07%) among 1306 patients in the Medtronic EEA™ circular stapler with Tri-Staple™ technology cohort. Comparative analyses revealed no difference comparing Ethicon manual circular staplers with Medtronic EEA™ circular staplers with Tri-Staple™ technology (risk ratio [RR], 0.72; 95% CI, 0.52-1.01) or comparing Medtronic EEA™ circular staplers with DST™ technology to Tri-Staple™ technology (RR, 0.75; 95% CI, 0.53-1.06). CONCLUSION: In this analysis of a large cohort of patients undergoing a left-sided colorectal surgery from a U.S. hospital database, the risk of AL observed with manual two-row circular staplers was similar to that seen with three-row devices. This study affirms the safety of manual two-row circular staplers in colorectal anastomosis.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Colon_e_reto Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Fístula Anastomótica Limite: Adult / Humans Idioma: En Revista: Int J Colorectal Dis Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Colon_e_reto Base de dados: MEDLINE Assunto principal: Neoplasias Colorretais / Fístula Anastomótica Limite: Adult / Humans Idioma: En Revista: Int J Colorectal Dis Assunto da revista: GASTROENTEROLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Estados Unidos