[Determination of 4-methyl-2-pentanol in workplace air by solvent desorption-gas chromatography].
Chen, G L; Tan, Q; Feng, Y J; Lan, H J; Yang, X W; Zhou, X Q.
Afiliação
  • Chen GL; Laboratory Department, Foshan Institute of Occupational Disease Prevention and Control, Foshan Occupational Health Research Institute, Foshan 528000, China.
  • Tan Q; Laboratory Department, Foshan Institute of Occupational Disease Prevention and Control, Foshan Occupational Health Research Institute, Foshan 528000, China.
  • Feng YJ; Laboratory Department, Foshan Nanhai District Center for Disease Control and Prevention, Foshan 528200, China.
  • Lan HJ; Laboratory Department, Foshan Nanhai District Center for Disease Control and Prevention, Foshan 528200, China.
  • Yang XW; Laboratory Department, Foshan Nanhai District Center for Disease Control and Prevention, Foshan 528200, China.
  • Zhou XQ; Department of Occupational Health and Occupational Medicine, School of Public Health, Southern Medical University, Guangzhou 510515, China.
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi ; 41(10): 859-862, 2023 Oct 20.
Article em Zh | MEDLINE | ID: mdl-37935555
Objective: To establish a method for the determination of 4-methyl-2-pentanol in the air of workplace by gas chromatography. Methods: In January 2022, 4-methyl-2-pentanol in the air of workplace was collected by activated carbontube, eluted with dichloromethane-methanol (95∶5, V/V), separated by capillary column and determined by gas chromatogram. Results: The limit of detection for 4-methyl-2-pentanol was 0.04 µg/ml. The linear range of 4-methyl-2-pentanol was 0.16-1616.60 µg/ml, with the regression equation of y=1.94x-5.48, and the coefficient correlation was 0.99958, and the minimum detection concentration was 0.03 mg/m(3) (collected sample volume was 1.50 L). The within-run precisions were 1.08%-1.75% and the between-run precisions were 1.41%-2.52%. The desorption rates were 95.15%-99.91%. The samples could be stored at least 3 days at room temperature and 7 days at 4 ℃ without significant loss. Conclusion: The method has the advantages of good precision, high sensitivity and simple operation. It is suitable for the determination of 4-methyl-2-pentanol in the air of workplace.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Poluentes Ocupacionais do Ar Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Assunto da revista: MEDICINA OCUPACIONAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Poluentes Ocupacionais do Ar Idioma: Zh Revista: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi Assunto da revista: MEDICINA OCUPACIONAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China