Your browser doesn't support javascript.
loading
Recombinant mannan-binding lectin magnetic beads increase pathogen detection in immunocompromised patients.
Xiao-Ping, Chen; Hao, Zheng; Ru-Li, Feng; Jin-Xing, Lu; Yu-Jun, Dong; Ze-Yin, Liang.
Afiliação
  • Xiao-Ping C; National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China.
  • Hao Z; National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China.
  • Ru-Li F; Clinical Laboratory of Peking University First Hospital, XiShiKu Street 8, XiCheng District, Beijing, 86-10-83572211, China.
  • Jin-Xing L; National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China.
  • Yu-Jun D; Department of Hematology, Peking University First Hospital, XiShiKu Street 8, XiCheng District, Beijing, 86-10-83572211, China. dongy@hsc.pku.edu.cn.
  • Ze-Yin L; Department of Hematology, Peking University First Hospital, XiShiKu Street 8, XiCheng District, Beijing, 86-10-83572211, China. walzyaw@163.com.
Appl Microbiol Biotechnol ; 108(1): 193, 2024 Feb 03.
Article em En | MEDLINE | ID: mdl-38308716
ABSTRACT
The microbiological diagnosis of infection for hematological malignancy patients receiving chemotherapy or allogeneic hematopoietic stem cell transplantation (allo-HSCT) patients relies primarily on standard microbial culture, especially blood culture, which has many shortcomings, such as having low positive rates, being time-consuming and having a limited pathogenic spectrum. In this prospective observational self-controlled test accuracy study, blood, cerebrospinal fluid (CSF), and bronchoalveolar lavage fluid (BALF) samples were collected from chemotherapy or allo-HSCT patients with clinical symptoms of infections who were hospitalized at Peking University First Hospital. Possible pathogens were detected by the method based on recombinant mannan-binding lectin (MBL) magnetic bead enrichment (M1 method) and simultaneously by a standard method. The analytical sensitivity of M1 method was close to that of standard culture method. Besides, the turn-around time of M1-method was significantly shorter than that of standard culture method. Moreover, the M1 method also added diagnostic value through the detection of some clinically relevant microbes missed by the standard method. M1 method could significantly increase the detection efficiency of pathogens (including bacteria and fungi) in immunocompromised patients. KEY POINTS • The detection results of M1-method had a high coincidence rate with that of standard method • M1 method detected many pathogens which had not been found by standard clinic method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Lectina de Ligação a Manose Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Appl Microbiol Biotechnol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Lectina de Ligação a Manose Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Appl Microbiol Biotechnol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China