Your browser doesn't support javascript.
loading
MRI 3D SPACE T2WI for Pituitary Adenoma Cavernous Sinus Invasion Diagnosis.
Chen, Yuyang; Cai, Shengyu; Li, Xiu; Zhang, Jianhe; Wei, Liangfeng; Wang, Shousen.
Afiliação
  • Chen Y; Neurosurgery, Fujian Medical University Fuzhou Clinical Medical College (900th Hospital), Fuzhou, China.
  • Cai S; Neurosurgery, Fujian Medical University Fuzhou Clinical Medical College (900th Hospital), Fuzhou, China; Neurosurgery, Second Affiliated Hospital of Fujian Medical University, Quanzhou, China.
  • Li X; Neurosurgery, Fujian Medical University Fuzhou Clinical Medical College (900th Hospital), Fuzhou, China.
  • Zhang J; Neurosurgery, Fujian Medical University Fuzhou Clinical Medical College (900th Hospital), Fuzhou, China.
  • Wei L; Neurosurgery, Fujian Medical University Fuzhou Clinical Medical College (900th Hospital), Fuzhou, China.
  • Wang S; Neurosurgery, Fujian Medical University Fuzhou Clinical Medical College (900th Hospital), Fuzhou, China. Electronic address: wshsen1965@126.com.
World Neurosurg ; 185: e1257-e1267, 2024 05.
Article em En | MEDLINE | ID: mdl-38514027
ABSTRACT

OBJECTIVE:

This study aims to assess the utility of magnetic resonance imaging (MRI) 3D SPACE T2-weighted imaging (T2WI) sequences in evaluating cavernous sinus invasion by pituitary adenomas.

METHODS:

Data were collected from patients who underwent continuous pituitary MRIexaminations at the Medical Imaging Center of our hospital from October 2019 to February 2021. Eligible cases were evaluated for sagittal and axial T1WI sequences, coronal 3D SPACE T2WI sequences, and sagittal and coronal enhanced T1-weighted imaging (T1WI) sequences using the INFINITT PACS workstation. The Wilcoxon signed-rank test for paired samples and the Mann-Whitney U test for 2 independent samples were used to statistically analyze differences in image quality scores among various groups. In addition, the sensitivity, specificity, positive predictive value, and negative predictive value of each observation index were compared with intraoperative results.

RESULTS:

3D SPACE T2WI showed superior cavernous sinus imaging quality compared with contrast enhanced T1WI and T2WI plain scans (P < 0.05). The sensitivity, specificity, positive predictive value, and negative predictive value were 100%, 90.0%, 55.60%, and 100.0%, respectively. The accuracy for pituitary adenoma invasiveness diagnosis based on cavernous sinus medial wall integrity was 94.40%.

CONCLUSIONS:

The imaging quality of the medial wall of the cavernous sinus on the 3D SPACE T2WI plain scan sequence surpassed that of contrast enhanced T1WI TSE-enhanced scans and T2WI TSE plain scans. The continuous observation of the medial wall of the cavernous sinus using this sequence holds great diagnostic value for assessing cavernous sinus invasion by pituitary adenomas. This strategy is more reliable than traditional MRI observation indicators.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Neoplasias Hipofisárias / Imageamento por Ressonância Magnética / Adenoma / Seio Cavernoso / Imageamento Tridimensional / Invasividade Neoplásica Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: World Neurosurg / World neurosurgery (Online) Assunto da revista: NEUROCIRURGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Neoplasias Hipofisárias / Imageamento por Ressonância Magnética / Adenoma / Seio Cavernoso / Imageamento Tridimensional / Invasividade Neoplásica Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: World Neurosurg / World neurosurgery (Online) Assunto da revista: NEUROCIRURGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China