ABSTRACT
Background:
Lateral clavicle fractures represent approximately 10-15% of all clavicle fractures. However, controversy exists regarding the optimal surgical treatment because of instability associated with the coracoclavicular (CC) ligament injury and a small lateral fragment. The purpose of this study was to evaluate the radiological and clinical outcomes of arthroscopically assisted CC stabilization using a suture button device for lateral clavicle fractures accompanied by CC ligament injury.Methods:
A retrospective observational study involved six patients with modified Neer type IIB fractures, which were treated with the technique and followed for 12 months. Postoperative range of motion (ROM) and X-rays were evaluated every 3 months. Shoulder functional scores (University of California Los Angeles score, Japanese Orthopedics Association score) and visual analog scale (VAS) scores for pain (at rest, at night, and during motion) and for satisfaction were analyzed 12 months after surgery.Results:
Early phase ROM recovery and excellent outcomes were achieved. All patients achieved bone union. Slight superior clavicle displacement and bone hole dilation occurred with no critical complications.Conclusions:
Arthroscopically assisted CC stabilization with a suture button device for unstable lateral clavicle fractures can produce satisfactory radiological and clinical results.