Your browser doesn't support javascript.
loading
Sensitive and effective method with 96-well plate for determination of levamlodipine in human plasma using LC-MS/MS.
Dong, Lingfang; Li, Kun; Gao, Shan; Wang, Wenyi; Feng, Yinghua; Zhang, Jingying; Yang, Jie; Dong, Weifeng; Zhang, Wei.
Afiliação
  • Dong L; Department of Pharmacy, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China.
  • Li K; Department of Pharmacy, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China.
  • Gao S; Department of Pharmacy, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China.
  • Wang W; Department of Day Surgery, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China.
  • Feng Y; Department of Pharmacy, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China.
  • Zhang J; Department of Pharmacy, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China.
  • Yang J; Department of Pharmacy, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China.
  • Dong W; Suzhou Guochen Biotechnology Co., Ltd., Jiangsu, 215000, China.
  • Zhang W; Department of Pharmacy, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou, Henan, 450003, China. Electronic address: zhangwei9001@126.com.
Anal Biochem ; 691: 115556, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38705226
ABSTRACT
we developed an effective protein precipitation method for determination of levamlodipine in human plasma using LC-MS/MS. Sample extraction was carried out by using liquid-liquid extraction in 96-well plate format. (S)-Amlodipine-d4 was used as internal standard (IS). The chromatographic separation was achieved using Philomen Chiral MX (2) column (3 µm, 2.1 × 100 mm). Mobile phase A was comprised of Acetonitrile (ACN), Mono ethanol amine (MEA) and Iso-Propyl alcohol (IPA) (1000110, v/v/v), Mobile phase B was IPA-ACN (21, v/v). The flow rate was 0.4 mL/min. The total run time of each sample was 4.0 min with gradient elution. LC-MS/MS spectra were generated in positive ion mode, and multiple reaction monitoring (MRM) was used to detect the following transitions m/z 409.20 â†’ 238.15 for levamlodipine and 415.25 â†’ 240.20 for (S)-Amlodipine-d4 (the IS). The method was linear from 50 to 10000 pg/mL(R2=0.9988489),and the lower limit of quantification (LLOQ) was 50 pg/mL. This method was applied to a bioequivalence study of levamlodipine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Niacina Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Niacina Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China