Your browser doesn't support javascript.
loading
Pars interarticularis screws for posterior cervical fusion - investigating a new trajectory using a CT-based multiplanar reconstruction: Part I.
Lener, Sara; Wipplinger, Christoph; Abramovic, Anto; Koller, Heiko; Thomé, Claudius; Verius, Michael; Hartmann, Sebastian.
Afiliação
  • Lener S; Department of Neurosurgery, Medial University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria. sara.lener@i-med.ac.at.
  • Wipplinger C; Department of Neurosurgery, Medial University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Abramovic A; Department of Neurosurgery, Medial University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Koller H; Department of Orthopedics and Traumatology, Paracelsus Medical University, Salzburg, Austria.
  • Thomé C; Department of Neurosurgery, Medial University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
  • Verius M; Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
  • Hartmann S; Department of Neurosurgery, Medial University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
Acta Neurochir (Wien) ; 166(1): 295, 2024 Jul 11.
Article em En | MEDLINE | ID: mdl-38990411
ABSTRACT

BACKGROUND:

Lateral mass screw fixation is the standard for posterior cervical fusion between C3 and C6. Traditional trajectories stabilize but carry risks, including nerve root and vertebral artery injuries. Minimally invasive spine surgery (MISS) is gaining popularity, but trajectories present anatomical challenges. RESEARCH QUESTION This study proposes a novel pars interarticularis screw trajectory to address these issues and enhance in-line instrumentation with cervical pedicle screws. MATERIALS AND

METHODS:

A retrospective analysis of reformatted cervical CT scans included 10 patients. Measurements of the pars interarticularis morphology were performed on 80 segments (C3-C6). Two pars interarticularis screw trajectories were evaluated Trajectory A (upper outer quadrant entry, horizontal trajectory) and Trajectory B (lower outer quadrant entry, cranially pointed trajectory). These were compared to standard lateral mass and cervical pedicle screw trajectories, assessing screw lengths, angles, and potential risks to the spinal canal and transverse foramen.

RESULTS:

Trajectory B showed significantly longer pars lengths (15.69 ± 0.65 mm) compared to Trajectory A (12.51 ± 0.24 mm; p < 0.01). Lateral mass screw lengths were comparable to pars interarticularis screw lengths using Trajectory B. Both trajectories provided safe angular ranges, minimizing the risk to delicate structures.

DISCUSSION:

and Conclusion. Pars interarticularis screws offer a viable alternative to lateral mass screws for posterior cervical fusion, especially in MISS contexts. Trajectory B, in particular, presents a feasible and safe alternative, reducing the risk of vertebral artery and spinal cord injury. Preoperative assessment and intraoperative technologies are essential for successful implementation. Biomechanical validation is needed before clinical application.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Tomografia Computadorizada por Raios X / Vértebras Cervicais Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Neurochir (Wien) / Acta neurochir / Acta neurochirurgica Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Áustria

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Fusão Vertebral / Tomografia Computadorizada por Raios X / Vértebras Cervicais Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Acta Neurochir (Wien) / Acta neurochir / Acta neurochirurgica Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Áustria