Innovative 3D printing and molding process for secondary-skin-collimator fabrication.
Sohn, James J; Kim, Haram; Stolen, Ethan; Chidel, Gibson; Jang, Sung; Furutani, Keith; Beltran, Chris; Lu, Bo.
Afiliação
  • Sohn JJ; Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637, United States of America.
  • Kim H; Varian Medical Systems, Palo Alto, CA 94304, United States of America.
  • Stolen E; Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637, United States of America.
  • Chidel G; School of Design, University of Illinois Chicago, Chicago, IL 60607, United States of America.
  • Jang S; School of Design, University of Illinois Chicago, Chicago, IL 60607, United States of America.
  • Furutani K; Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL 32224, United States of America.
  • Beltran C; Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL 32224, United States of America.
  • Lu B; Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL 32224, United States of America.
Biomed Phys Eng Express ; 10(5)2024 Aug 12.
Article em En | MEDLINE | ID: mdl-39094590
ABSTRACT
Purpose. Secondary skin collimation (SSC) is essential for shielding normal tissues near tumors during electron and orthovoltage radiation treatments. Traditional SSC fabrication methods, such as crafting in-house lead sheets, are labor-intensive and produce SSCs with low geometric accuracy. This study introduces a workflow that integrated 3D scanning and 3D printing technologies with an in-house mold process, enabling the production of patient-specific SSCs within six hours.Methods. An anthropomorphic head phantom was scanned with a handheld 3D scanner. The resulting scan data was imported into 3D modeling software for design. The completed model was exported to a 3D printer as a printable file. Subsequently, molten Cerrobend was poured into the mold and allowed to set, completing the SSC production. Geometric accuracy was assessed using CT images, and the shielding effectiveness was evaluated through film dosimetry.Results. The 3D printed mold achieved submillimeter accuracy (0.5 mm) and exhibited high conformity to the phantom surface. It successfully endured the weight and heat of the Cerrobend during pouring and curing. Dosimetric analysis conducted with radiochromic film demonstrated good agreement between the measured and expected attenuation values of the SSC slab, within ±3%.Conclusions. This study presents a proof of concept for novel mold room workflows that produce patient-specific SSCs within six hours, a significant improvement over the traditional SSC fabrication process, which takes 2-3 days. The submillimeter accuracy and versatility of 3D scanning and printing technologies afford greater design freedom and enhanced delivery accuracy for cases involving irregular geometries.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Pele / Imagens de Fantasmas / Impressão Tridimensional Limite: Humans Idioma: En Revista: Biomed Phys Eng Express Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos