Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Heart Vessels ; 32(9): 1077-1084, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28432385

RESUMO

Beneficial properties of bioresorbable vascular scaffolds (BVS) regarding to vasomotility restoration and no caging of the vessel make them attractive devices in chronic total occlusions (CTO) revascularization. However, more evidence is needed attending to their use in this specific setting. We aim to determine feasibility and safety of BVS use in CTO revascularization attending to struts coverage and apposition, as well as re-stenosis and stent thrombosis (ST) rates. 29 BVS were deployed in 9 CTO lesions revascularization (mean J-CTO score ≥3) with an acute procedural success rate of 100%. Clinical and angiographic follow-up was performed 6 months later, including intracoronary analyses from optical coherence tomography (OCT) images. 44,723 struts were analyzed within the total 636 mm of scaffolded vessel. Mean length scaffolded per lesion was 70.66 ± 31.01 mm with a mean number of 3.22 BVS. 2051 struts (4.59%) were identified as uncovered, being most of them (98.4%) neither malapposed nor disrupted. Mean thickness of struts' coverage was 0.13 ± 0.05 mm. Incomplete strut apposition (ISA) percentage was 0% as no malapposed struts were detected and 134 struts were identified as disrupted, which represents a 0.29% from the total. Mean vessel, scaffold, and lumen diameters were 3.87 ± 0.51, 2.97 ± 0.49, and 2.68 ± 0.50 mm, respectively. Neither in-stent re-stenosis nor ST was detected. During follow-up, none of our patients died, suffered from stroke or needed target lesion revascularization. Clinical and angiographic 6-month follow-up (including OCT analyses) of BVS in CTO revascularization suggests their effectiveness and safety, even in very complex chronic occluded lesions. Nevertheless, more evidence is needed.


Assuntos
Implantes Absorvíveis , Oclusão Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Angiografia Coronária , Oclusão Coronária/diagnóstico , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Alicerces Teciduais , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA