Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heart Rhythm ; 12(8): 1789-97, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25998895

RESUMO

BACKGROUND: The electrocardiographic T-wave peak to T-wave end interval (Tpe) correlates with dispersion of ventricular repolarization (DVR). Increased DVR increases propensity toward electrical reentry that can cause ventricular tachyarrhythmia. The baseline rate-corrected Tpe (Tpec) has been shown to predict ventricular tachyarrhythmia and death in multiple patient populations but not among cardiomyopathic patients undergoing insertion of an implantable cardioverter-defibrillator (ICD) for primary prevention. OBJECTIVE: The purpose of this study was to assess the risk stratification ability of the Tpec in patients with systolic cardiomyopathy without prior ventricular tachyarrhythmia (ie, the primary prevention population). METHODS: We performed prospective follow-up of 305 patients (73% men; left ventricular ejection fraction [LVEF] 23 ± 7%) with LVEF ≤35% and an ICD implanted for primary prevention. Baseline ECGs were analyzed with automated algorithms. Endpoints were ventricular tachycardia (VT)/ventricular fibrillation (VF), death, and a combined endpoint of VT/VF or death, assessed by device follow-up and Social Security Death Index query. RESULTS: The average Tpec was 107 ± 22 ms. During device clinic follow-up of 31 ± 23 months, 82 patients (27%) had appropriate ICD therapy for VT/VF, and during mortality follow-up of 49 ± 21 months, 91 patients (30%) died. On univariable analysis, Tpec predicted VT/VF, death, and the combined endpoint of VT/VF or death (P < .05 for each endpoint). Multivariable analysis included univariable predictors among demographics, clinical data, laboratory data, medications used, and electrocardiography parameters. After correction, Tpec remained predictive of VT/VF (hazard ratio [HR] per 10-ms increase 1.16, P = .009), all-cause mortality (HR per 10 ms 1.13, P = .05), and the combined endpoint (HR per 10 ms 1.17, P = .001). CONCLUSION: Tpec independently predicts both VT/VF and overall mortality in patients with systolic dysfunction and ICDs implanted for primary prevention.


Assuntos
Cardiomiopatias/complicações , Desfibriladores Implantáveis , Eletrocardiografia , Prevenção Primária/métodos , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia
2.
Europace ; 14(8): 1172-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22277646

RESUMO

AIMS: The interval between the T-wave's peak and end (Tpe), an electrocardiographic (ECG) index of ventricular repolarization, has been proposed as an indicator of arrhythmic risk. We aimed to clarify the clinical usefulness of Tpe for risk stratification. METHODS AND RESULTS: We evaluated 327 patients with left ventricular ejection fraction (LVEF) ≤ 35% (75% male, LVEF 23 ± 7%). All patients had an implanted implantable cardioverter-defibrillator (ICD). Clinical data and ECGs were analysed at baseline. Prospective follow-up for the endpoints of appropriate ICD therapy and mortality was conducted via periodic device interrogation, chart review, and the Social Security Death Index. During device clinic follow-up of 17 ± 12 months, 59 (18%) patients had appropriate ICD therapy, and during mortality follow-up of 30 ± 13 months, 67 (21%) patients died. A longer Tpe(c) predicted appropriate ICD therapy, death, and the combination of appropriate ICD therapy or death (P< 0.01 for each endpoint). On multivariable analysis correcting for other univariable predictors, Tpe(c) remained predictive of ICD therapy [hazard ratio (HR) per 10 ms increase: 1.16, P= 0.02], all-cause mortality (HR per 10 ms: 1.14, P= 0.03), and the composite endpoint of ICD therapy or death (HR per 10 ms: 1.16, P< 0.01). CONCLUSIONS: In patients with left ventricular systolic dysfunction and an implanted ICD, Tpe(c) independently predicts both ventricular tachyarrhythmia and overall mortality.


Assuntos
Taquicardia Ventricular/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco/métodos , Análise de Sobrevida , Taquicardia Ventricular/etiologia , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA