1.
Cardiovasc Revasc Med ; 21(4): 522-526, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31439442

RESUMO

INTRODUCTION: Takotsubo Syndrome (TS) patients are at high risk of developing atrial fibrillation. We sought to investigate the outcomes and economic impact of atrial fibrillation on TS patients utilizing the National Inpatient Sample. METHODS: Patients with TS were identified in the National Inpatient Sample (NIS) database between 2010 and 2014 using the International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM), and subsequently were divided into two groups, those with and without atrial fibrillation. The primary outcome was all-cause in-hospital mortality in the two groups. Secondary outcomes were in-hospital complications. We also evaluated the length of hospital stay and the cost of hospitalization. Propensity score-matched analysis was performed to address potential confounding factors. RESULTS: Among the study population, the prevalence of atrial fibrillation was 17.57%. After matching, the atrial fibrillation group had no significant increase of in-hospital mortality (OR: 1.13; 95% CI: 0.94-1.35, p = 0.211). However, atrial fibrillation patients were more likely to develop cardiac arrest and ventricular arrhythmias (OR: 1.51, 95% CI: 1.26-1.80, p < 0.0001), have higher rate of major cardiac complications when combined as a single endpoint in-hospital complication (OR: 1.16, 95% CI: 1.04-1.29, p: 0.006), also they were more likely to stay longer in hospital (OR: 1.13, 95% CI: 1.08-1.19, p < 0.0001), and have increased cost of hospitalization (OR: 1.13, 95% CI 1.07-1.20, p < 0.0001). CONCLUSION: Atrial fibrillation does not increase in-hospital mortality in patients presenting with TS. However atrial fibrillation is associated with an increased risk of ventricular arrhythmias, length of stay, non-routine discharges and cost of hospitalization.


Assuntos
Fibrilação Atrial/mortalidade , Mortalidade Hospitalar , Pacientes Internados , Cardiomiopatia de Takotsubo/mortalidade , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/economia , Fibrilação Atrial/terapia , Bases de Dados Factuais , Feminino , Custos Hospitalares , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Pontuação de Propensão , Medição de Risco , Fatores de Risco , Cardiomiopatia de Takotsubo/diagnóstico , Cardiomiopatia de Takotsubo/economia , Cardiomiopatia de Takotsubo/terapia , Fatores de Tempo , Estados Unidos/epidemiologia
3.
J Interv Cardiol ; 31(6): 925-931, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30456770

RESUMO

BACKGROUND: The concomitant presence of atrial fibrillation (AF) in the setting of Transcatheter Mitral Valve Repair (TMVR) represents a clinical challenge. Despite the high AF burden in patients presenting for the TMVR procedure, there are no studies that evaluate the impact of AF on in-hospital outcomes of TMVR in a nationally representative United States sample reflecting real practice. Therefore, we sought to study the outcomes of AF patients undergoing TMVR. METHODS AND RESULTS: The study included 1026 patients from the National Inpatient Sample (NIS) registry. Patients (age ≥18 years) who had undergone TAVR as a primary procedure from 2011 to 2014 were included, using the ICD-9-CM diagnostic codes. We examined patient characteristics and in-hospital outcomes. To account for patient and hospital-level baseline differences, we performed propensity score-matched analysis. The prevalence of AF was approximately 56%. After adjusting for patient-level and hospital-level characteristics, there was no statistical difference regarding in-hospital mortality (odds ratio [OR] 0.72, 95%CI 0.29-1.80, P = 0.487), post-TMVR complications, length of stay (OR 1.15, 95%CI 0.97-1.38, P = 0.111), and cost of hospitalization (OR 1.04, 95%CI 0.94-1.14, P = 0.475) between the group with AF versus without AF. However, patients with AF were more likely to have non-routine hospital discharge (42.94% vs 35.48% P = 0.02). CONCLUSION: AF is a frequently encountered arrhythmia among patients undergoing TMVR with MitraClip. However, TMVR can be performed safely in the vast majority of patients, irrespective of their baseline rhythm.


Assuntos
Fibrilação Atrial/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Idoso , Fibrilação Atrial/epidemiologia , Feminino , Custos Hospitalares/estatística & dados numéricos , Mortalidade Hospitalar , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/epidemiologia , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos
4.
Am J Cardiol ; 122(5): 838-843, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30037424

RESUMO

Comparative outcomes of transcatheter aortic valve implantation (TAVI) in patients with and without hypothyroidism were not previously reported. This study aimed to appraise the clinical outcomes and impact of hypothyroidism on patients who underwent TAVI. Patients with hypothyroidism who underwent TAVI from 2011 to 2014 were identified in the National Inpatient Sample database using the International Classification of Diseases, ninth Revision, Clinical Modification. The primary outcome was the effect of hypothyroidism on inpatient mortality. Secondary outcomes were the impact of hypothyroidism on post-TAVI complications. We also evaluated the length of hospital stay and the cost of hospitalization. Propensity score-matched analysis was performed to address potential confounding. The hypothyroid patients who underwent TAVI had no significant increase in the risk of in-hospital mortality (odds ratio 0.78; 95% confidence interval 0.51 to 1.21, p = 0.282), or most postprocedural complications. However, hypothyroid patients were more likely to develop hemorrhage requiring transfusion (odds ratio 1.36, 95% confidence interval 1.05 to 1.76, p = 0.043). In conclusion, TAVI is a feasible and relatively safe alternative with reasonable in-hospital outcomes in patients with hypothyroidism and severe symptomatic aortic stenosis. However, hypothyroid patients are more likely to require a blood transfusion after TAVI. Additional randomized trials are needed to evaluate TAVR outcomes in hypothyroid patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Hipotireoidismo/complicações , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Transfusão de Componentes Sanguíneos/estatística & dados numéricos , Feminino , Custos Hospitalares , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Resultado do Tratamento
5.
Am J Cardiol ; 121(12): 1587-1592, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29622287

RESUMO

The objective of this study was to evaluate the financial implications and the impact of pre-existing atrial fibrillation (AF) on in-hospital outcomes in patients who underwent transcatheter aortic valve implantation (TAVI) using the Nationwide Inpatient Sample (NIS) database. We identified patients who underwent TAVI from 2011 to 2014. The primary end point was the effect of pre-existing AF on in-hospital mortality. Secondary end points included periprocedural cardiac complications, stroke, and hemorrhage requiring transfusion. We also assessed length of stay (LOS) and cost of hospitalization. A mixed-effect logistic model was used for clinical end points, and a linear mixed model was used for cost and LOS. In 6,778 patients who underwent TAVI (46.1% women and 81.4 ± 8.5 years old), the incidence of AF was 43.3%. After adjusting for patient- and hospital-level characteristics, pre-existing AF was not found to influence in-hospital mortality (odds ratio 1.05, 95% confidence interval 0.80 to 1.36). AF was associated with an increased risk of periprocedural cardiac complications (odds ratio 1.46, 95% confidence interval 1.22 to 1.75), longer LOS (p <0.001) and an increased cost of hospitalization (US$51,852 vs US$49,599). In conclusion, pre-existing AF did not impact in-hospital mortality in TAVI patients but was associated with increased cardiac complications, a longer hospital LOS, and a higher cost of hospitalization.


Assuntos
Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/epidemiologia , Custos Hospitalares/estatística & dados numéricos , Mortalidade Hospitalar , Tempo de Internação/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Arritmias Cardíacas/economia , Arritmias Cardíacas/epidemiologia , Estimulação Cardíaca Artificial/estatística & dados numéricos , Tamponamento Cardíaco/economia , Tamponamento Cardíaco/epidemiologia , Comorbidade , Bases de Dados Factuais , Feminino , Parada Cardíaca/economia , Parada Cardíaca/epidemiologia , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/epidemiologia , Humanos , Tempo de Internação/economia , Modelos Lineares , Modelos Logísticos , Masculino , Infarto do Miocárdio/economia , Infarto do Miocárdio/epidemiologia , Marca-Passo Artificial , Derrame Pericárdico/economia , Derrame Pericárdico/epidemiologia , Complicações Pós-Operatórias/economia , Hemorragia Pós-Operatória/economia , Hemorragia Pós-Operatória/epidemiologia , Acidente Vascular Cerebral/economia , Acidente Vascular Cerebral/epidemiologia , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA