Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 158: 405-415, 2018 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-29940496

RESUMO

This review describes briefly the high rate of counterfeiting of antimicrobial drugs with focus upon its immediate health consequences. The major part of this review encompasses accounts of the improvements achieved in the domain of miniaturization of capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D). The application of this principle into the development of portable devices as well as its application to counter the health-system-crippling phenomenon of counterfeit antibiotic formulations, are discussed in the context of developing countries.


Assuntos
Antibacterianos/análise , Medicamentos Falsificados/análise , Fraude/prevenção & controle , Química Verde/métodos , Microquímica/métodos , Países em Desenvolvimento/economia , Condutividade Elétrica , Eletroforese Capilar/economia , Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Eletroforese Capilar/tendências , Fraude/economia , Química Verde/economia , Química Verde/instrumentação , Química Verde/tendências , Microquímica/economia , Microquímica/instrumentação , Microquímica/tendências , Sensibilidade e Especificidade
2.
Electrophoresis ; 39(20): 2521-2529, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29645291

RESUMO

A simple and robust capillary zone electrophoresis method was developed and validated for the determination of amoxicillin and clavulanate, ampicillin, phenoxymethyl penicillin (Pen V) as well as flucloxacillin. Capacitively coupled contactless conductivity detection was employed as detection mode that makes CE a simple and economic tool for money-constrained laboratories. The developed method is straightforward and user-friendly. It offers good sensitivity and sufficient selectivity for the routine assay of the selected penicillins. The repeatabilities were <1.9% RSD for relative peak areas and <1% RSD for migration times for all the analytes. The method showed good linearity (R2  > 0.995) within the 80-120% range of the target concentration (0.5 mg/mL) for each antibiotic. The accuracy of the method, evaluated by standard fortification at three levels, was good for all the analytes. An extended robustness study was performed by varying ±10% of the optimum value of TRIS concentration, l-histidine concentration and temperature in a full factorial design at two levels. This was to evaluate larger than usual variability of factors on the assay value, in order to better cover potential global variance in lab conditions and equipment. Finally, the method was applied for the determination of percent (%) content of all antibiotics in available formulations.


Assuntos
Eletroforese Capilar/economia , Eletroforese Capilar/métodos , Penicilinas/análise , Condutividade Elétrica , Limite de Detecção , Modelos Lineares , Penicilinas/química , Reprodutibilidade dos Testes
3.
J Pharm Biomed Anal ; 75: 199-206, 2013 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-23277151

RESUMO

A simple, robust and fast high-performance liquid chromatographic method is described for the analysis of oxytetracycline and its related impurities. The principal peak and impurities are all baseline separated in 20 min using an Inertsil C8 (150 mm × 4.6 mm, 5 µm) column kept at 50 °C. The mobile phase consists of a gradient mixture of mobile phases A (0.05% trifluoroacetic acid in water) and B (acetonitrile-methanol-tetrahydrofuran, 80:15:5, v/v/v) pumped at a flow rate of 1.3 ml/min. UV detection was performed at 254 nm. The developed method was validated for its robustness, sensitivity, precision and linearity in the range from limit of quantification (LOQ) to 120%. The limits of detection (LOD) and LOQ were found to be 0.08 µg/ml and 0.32 µg/ml, respectively. This method allows the separation of oxytetracycline from all known and 5 unknown impurities, which is better than previously reported in the literature. Moreover, the simple mobile phase composition devoid of non-volatile buffers made the method suitable to interface with mass spectrometry for further characterization of unknown impurities. The developed method has been applied for determination of related substances in oxytetracycline bulk samples available from four manufacturers. The validation results demonstrate that the method is reliable for quantification of oxytetracycline and its impurities.


Assuntos
Antibacterianos/análise , Contaminação de Medicamentos , Oxitetraciclina/análise , Antibacterianos/química , Antibacterianos/economia , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Europa (Continente) , Guias como Assunto , Limite de Detecção , Estrutura Molecular , Peso Molecular , Oxitetraciclina/química , Oxitetraciclina/economia , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Espectrofotometria Ultravioleta , Tetraciclinas/análise , Tetraciclinas/química
4.
J Pharm Biomed Anal ; 75: 94-104, 2013 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-23261805

RESUMO

The characterization of impurities present in micronomicin sulfate injection by liquid chromatography (LC) coupled with mass spectrometry (MS) is described. A reversed phase (RP)-LC method using a C18 column resistant to an alkaline (pH 11) aqueous mobile phase was developed and coupled to MS with an electrospray ionization (ESI) source in the positive ion mode which provides MS(n) capability. A total of thirty six impurities were detected in commercial samples: five impurities were identified by comparison of their fragmentation patterns with those of available related substances, eleven of them were identified in accordance with relevant literature, while the other twenty impurities were newly identified using the MS/MS spectra of the available related reference substances as interpretative templates combined with knowledge of the nature of functional group fragmentation behaviors. This work was applied to evaluate the quality of micronomicin sulfate injection from different manufacturers.


Assuntos
Aminoglicosídeos/química , Antibacterianos/química , Contaminação de Medicamentos , Aminoglicosídeos/administração & dosagem , Aminoglicosídeos/economia , Antibacterianos/administração & dosagem , Antibacterianos/economia , China , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Gentamicinas , Injeções , Estrutura Molecular , Controle de Qualidade , Espectrometria de Massas por Ionização por Electrospray , Ésteres do Ácido Sulfúrico/administração & dosagem , Ésteres do Ácido Sulfúrico/química , Ésteres do Ácido Sulfúrico/economia , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA