Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
JACC Heart Fail ; 12(7): 1212-1222, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38530702

RESUMO

BACKGROUND: Inadequate inclusion in clinical trial enrollment may contribute to health inequities by evaluating interventions in cohorts that do not fully represent target populations. OBJECTIVES: The aim of this study was to determine if characteristics of patients with heart failure (HF) enrolled in a pivotal trial are associated with who receives an intervention after approval. METHODS: Demographics from 2,017,107 Medicare patients hospitalized for HF were compared with those of the first 10,631 Medicare beneficiaries who received implantable pulmonary artery pressure sensors. Characteristics of the population studied in the pivotal CHAMPION (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients) clinical trial (n = 550) were compared with those of both groups. All demographic data were analyzed nationally and in 4 U.S. regions. RESULTS: The Medicare HF cohort included 80.9% White, 13.3% African American, 1.9% Hispanic, 1.3% Asian, and 51.5% female patients. Medicare patients <65 years of age were more likely to be African American (33%) and male (58%), whereas older patients were mostly White (84%) and female (53%). Forty-one percent of U.S. HF hospitalizations occurred in the South; demographic characteristics varied significantly across all U.S. regions. The CHAMPION trial adequately represented African Americans (23% overall, 35% <65 years of age), Hispanic Americans (2%), and Asian Americans (1%) but underrepresented women (27%). The trial's population characteristics were similar to those of the first patients who received pulmonary artery sensors (82% White, 13% African American, 1% Asian, 1% Hispanic, and 29% female). CONCLUSIONS: Demographics of Centers for Medicare and Medicaid Services beneficiaries hospitalized with HF vary regionally and by age, which should be considered when defining "adequate" representation in clinical studies. Enrollment diversity in clinical trials may affect who receives early application of recently approved innovations.


Assuntos
Ensaios Clínicos como Assunto , Insuficiência Cardíaca , Medicare , Humanos , Masculino , Feminino , Insuficiência Cardíaca/terapia , Idoso , Estados Unidos , Pessoa de Meia-Idade , Seleção de Pacientes , Idoso de 80 Anos ou mais , Hospitalização/estatística & dados numéricos
2.
J Am Coll Cardiol ; 82(6): 473-485, 2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37532417

RESUMO

BACKGROUND: Cardiac troponin is used for risk stratification of patients with acute coronary syndromes; however, the role of testing in other settings remains unclear. OBJECTIVES: The aim of this study was to evaluate whether cardiac troponin testing could enhance risk stratification in patients with chronic coronary artery disease independent of disease severity and conventional risk measures. METHODS: In a prospective cohort of consecutive patients with symptoms suggestive of stable angina attending for outpatient coronary angiography, high-sensitivity cardiac troponin I was measured before angiography, and clinicians were blinded to the results. The primary outcome was myocardial infarction or cardiovascular death during follow-up. RESULTS: In 4,240 patients (age 66 years [IQR: 59-73 years], 33% female), coronary artery disease was identified in 3,888 (92%) who had 255 (6%) primary outcome events during a median follow-up of 2.4 years (IQR: 1.3-3.6 years). In patients with coronary artery disease, troponin concentrations were 2-fold higher in those with an event compared with those without (6.7 ng/L [IQR: 3.2-14.2 ng/L] vs 3.3 ng/L [IQR: 1.7-6.6 ng/L]; P < 0.001). Troponin concentrations were associated with the primary outcome after adjusting for cardiovascular risk factors and coronary artery disease severity (adjusted HR: 2.3; 95% CI: 1.7-3.0, log10 troponin; P < 0.001). A troponin concentration >10 ng/L identified patients with a 50% increase in the risk of myocardial infarction or cardiovascular death. CONCLUSIONS: In patients with chronic coronary artery disease, cardiac troponin predicts risk of myocardial infarction or cardiovascular death independent of cardiovascular risk factors and disease severity. Further studies are required to evaluate whether routine testing could inform the selection of high-risk patients for treatment intensification. (Myocardial Injury in Patients Referred for Coronary Angiography [MICA]; ISRCTN15620297).


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Humanos , Feminino , Idoso , Masculino , Doença da Artéria Coronariana/diagnóstico , Prognóstico , Biomarcadores , Estudos Prospectivos , Medição de Risco/métodos , Infarto do Miocárdio/diagnóstico , Troponina I
3.
ESC Heart Fail ; 10(5): 3046-3054, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37591524

RESUMO

AIMS: Previous cost-effectiveness analysis suggests that CardioMEMS is cost-effective compared with usual care for patients with persistent New York Heart Association class III symptoms and at least one heart failure (HF) hospitalization within 12 months. The aim of the paper is to perform an update of the cost-effectiveness analysis of CardioMEMS using the most recent data from the published literature. METHODS AND RESULTS: A Microsoft Excel Markov model from a previous UK cost-effectiveness study of CardioMEMS was updated using the clinical effectiveness of pulmonary artery pressure (PAP)-guided treatment derived from the pivotal trials. The model included the device costs (and the implantation procedure and related complications), costs of remote monitoring, costs of HF-related hospitalizations, and costs of usual care. Quality-adjusted life years (QALYs) were estimated based on utilities from pivotal trials and published literature. Cost-effectiveness results were estimated as incremental cost per QALY gained of CardioMEMS compared with usual care. Scenario analyses were also performed using data from real-world studies that showed a significant decrease in HF-related hospitalizations. In the base case analysis over a time horizon of 10 years, PAP-guided HF therapy increased cost compared with usual care by £6337 (i.e. from £22 770 in usual care to £29 107 in PAP-guided HF therapy) and the QALYs per patient for usual care and PAP-guided patients were 2.62 and 2.94, respectively, reflecting an increase of 0.32 QALYs with PAP-guided treatment. The resultant incremental cost-effectiveness ratio (ICER), the ratio between incremental costs and the QALYs, is estimated at £19 761/QALY. Scenario analyses suggest that the ICER for CardioMEMS can range from being dominant to £27 910/QALY. Probabilistic sensitivity analyses suggested that PAP-guided HF therapy has 81.9% probability of being cost-effective at a threshold of £30 000/QALY. CONCLUSIONS: Our model suggests that CardioMEMS is likely to be cost-effective in the United Kingdom, at the currently considered thresholds of £20 000-30 000/QALY.

4.
Heart ; 107(23): 1905-1911, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33514522

RESUMO

OBJECTIVES: Non-contrast CT aortic valve calcium scoring ignores the contribution of valvular fibrosis in aortic stenosis. We assessed aortic valve calcific and non-calcific disease using contrast-enhanced CT. METHODS: This was a post hoc analysis of 164 patients (median age 71 (IQR 66-77) years, 78% male) with aortic stenosis (41 mild, 89 moderate, 34 severe; 7% bicuspid) who underwent echocardiography and contrast-enhanced CT as part of imaging studies. Calcific and non-calcific (fibrosis) valve tissue volumes were quantified and indexed to annulus area, using Hounsfield unit thresholds calibrated against blood pool radiodensity. The fibrocalcific ratio assessed the relative contributions of valve fibrosis and calcification. The fibrocalcific volume (sum of indexed non-calcific and calcific volumes) was compared with aortic valve peak velocity and, in a subgroup, histology and valve weight. RESULTS: Contrast-enhanced CT calcium volumes correlated with CT calcium score (r=0.80, p<0.001) and peak aortic jet velocity (r=0.55, p<0.001). The fibrocalcific ratio decreased with increasing aortic stenosis severity (mild: 1.29 (0.98-2.38), moderate: 0.87 (1.48-1.72), severe: 0.47 (0.33-0.78), p<0.001) while the fibrocalcific volume increased (mild: 109 (75-150), moderate: 191 (117-253), severe: 274 (213-344) mm3/cm2). Fibrocalcific volume correlated with ex vivo valve weight (r=0.72, p<0.001). Compared with the Agatston score, fibrocalcific volume demonstrated a better correlation with peak aortic jet velocity (r=0.59 and r=0.67, respectively), particularly in females (r=0.38 and r=0.72, respectively). CONCLUSIONS: Contrast-enhanced CT assessment of aortic valve calcific and non-calcific volumes correlates with aortic stenosis severity and may be preferable to non-contrast CT when fibrosis is a significant contributor to valve obstruction.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico , Meios de Contraste/farmacologia , Tomografia Computadorizada Multidetectores/métodos , Idoso , Progressão da Doença , Feminino , Fibrose/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
5.
JAMA Cardiol ; 4(6): 556-563, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31090869

RESUMO

Importance: In a randomized clinical trial, heart failure (HF) hospitalizations were lower in patients managed with guidance from an implantable pulmonary artery pressure sensor compared with usual care. It remains unclear if ambulatory monitoring could also improve long-term clinical outcomes in real-world practice. Objective: To determine the association between ambulatory hemodynamic monitoring and rates of HF hospitalization at 12 months in clinical practice. Design, Setting, and Participants: This matched cohort study of Medicare beneficiaries used claims data collected between June 1, 2014, and March 31, 2016. Medicare patients who received implants of a pulmonary artery pressure sensor were identified from the 100% Medicare claims database. Each patient who received an implant was matched to a control patient by demographic features, history of HF hospitalization, and number of all-cause hospitalizations. Propensity scoring based on comorbidities (arrhythmia, hypertension, diabetes, pulmonary disease, and renal disease) was used for additional matching. Data analysis was completed from July 2017 through January 2019. Exposures: Implantable pulmonary artery pressure monitoring system. Main Outcomes and Measures: The rates of HF hospitalization were compared using the Andersen-Gill method. Days lost owing to events were compared using a nonparametric bootstrap method. Results: The study cohort consisted of 1087 patients who received an implantable pulmonary artery pressure sensors and 1087 matched control patients. The treatment and control cohorts were well matched by age (mean [SD], 72.7 [10.2] years vs 72.9 [10.1] years) and sex (381 of 1087 female patients [35.1%] in each group), medical history, comorbidities, and timing of preimplant HF hospitalization. At 12 months postimplant, 616 HF hospitalizations occurred in the treatment cohort compared with 784 HF hospitalizations in the control cohort. The rate of HF hospitalization was lower in the treatment cohort at 12 months postimplant (hazard ratio [HR], 0.76 [95% CI, 0.65-0.89]; P < .001). The percentage of days lost to HF hospitalizations or death were lower in the treatment group (HR, 0.73 [95% CI, 0.64-0.84]; P < .001) and the percentage of days lost owing to all-cause hospitalization or death were also lower (HR, 0.77 [95% CI, 0.68-0.88]; P < .001). Conclusions and Relevance: Patients with HF who were implanted with a pulmonary artery pressure sensor had lower rates of HF hospitalization than matched controls and spent more time alive out of hospital. Ambulatory hemodynamic monitoring may improve outcomes in patients with chronic HF.


Assuntos
Pressão Sanguínea , Insuficiência Cardíaca/terapia , Hospitalização/estatística & dados numéricos , Monitorização Ambulatorial/métodos , Próteses e Implantes , Artéria Pulmonar , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Gerenciamento Clínico , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Medicare , Planejamento de Assistência ao Paciente , Pontuação de Propensão , Modelos de Riscos Proporcionais , Estados Unidos
6.
Circ Cardiovasc Imaging ; 11(12): e008325, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30558496

RESUMO

BACKGROUND: We assessed the feasibility of utilizing previously acquired computed tomography angiography (CTA) with subsequent positron-emission tomography (PET)-only scan for the quantitative evaluation of 18F-NaF PET coronary uptake. METHODS AND RESULTS: Forty-five patients (age 67.1±6.9 years; 76% males) underwent CTA (CTA1) and combined 18F-NaF PET/CTA (CTA2) imaging within 14 [10, 21] days. We fused CTA1 from visit 1 with 18F-NaF PET (PET) from visit 2 and compared visual pattern of activity, maximal standard uptake (SUVmax) values, and target to background ratio (TBR) measurements on (PET/CTA1) fused versus hybrid (PET/CTA2). On PET/CTA2, 226 coronary plaques were identified. Fifty-eight coronary segments from 28 (62%) patients had high 18F-NaF uptake (TBR >1.25), whereas 168 segments had lesions with 18F-NaF TBR ≤1.25. Uptake in all lesions was categorized identically on coregistered PET/CTA1. There was no significant difference in 18F-NaF uptake values between PET/CTA1 and PET/CTA2 (SUVmax, 1.16±0.40 versus 1.15±0.39; P=0.53; TBR, 1.10±0.45 versus 1.09±0.46; P=0.55). The intraclass correlation coefficient for SUVmax and TBR was 0.987 (95% CI, 0.983-0.991) and 0.986 (95% CI, 0.981-0.992). There was no fixed or proportional bias between PET/CTA1 and PET/CTA2 for SUVmax and TBR. Cardiac motion correction of PET scans improved reproducibility with tighter 95% limits of agreement (±0.14 for SUVmax and ±0.15 for TBR versus ±0.20 and ±0.20 on diastolic imaging; P<0.001). CONCLUSIONS: Coronary CTA/PET protocol with CTA first followed by PET-only allows for reliable and reproducible quantification of 18F-NaF coronary uptake. This approach may facilitate selection of high-risk patients for PET-only imaging based on results from prior CTA, providing a practical workflow for clinical application.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Radioisótopos de Flúor/farmacocinética , Placa Aterosclerótica/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Fluoreto de Sódio/farmacocinética , Idoso , Transporte Biológico , Doença da Artéria Coronariana/metabolismo , Vasos Coronários/metabolismo , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Placa Aterosclerótica/metabolismo
7.
JACC Cardiovasc Imaging ; 11(9): 1301-1310, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30190030

RESUMO

OBJECTIVES: This study sought to compare the performance of major guidelines for the assessment of stable chest pain including risk-based (American College of Cardiology/American Heart Association and European Society of Cardiology) and symptom-focused (National Institute for Health and Care Excellence) strategies. BACKGROUND: Although noninvasive testing is not recommended in low-risk individuals with stable chest pain, guidelines recommend differing approaches to defining low-risk patients. METHODS: Patient-level data were obtained from the PROMISE (Prospective Multicenter Imaging Study for Evaluation of Chest Pain) and SCOT-HEART (Scottish Computed Tomography of the Heart) trials. Pre-test probability was determined and patients dichotomized into low-risk and intermediate-high-risk groups according to each guideline's definitions. The primary endpoint was obstructive coronary artery disease on coronary computed tomography angiography. Secondary endpoints were coronary revascularization at 90 days and cardiovascular death or nonfatal myocardial infarction up to 3 years. RESULTS: In total, 13,773 patients were included of whom 6,160 had coronary computed tomography angiography. The proportions of patients identified as low risk by the American College of Cardiology/American Heart Association, European Society of Cardiology, and National Institute for Health and Care Excellence guidelines, respectively, were 2.5%, 2.5%, and 10.0% within PROMISE, and 14.0%, 19.8%, and 38.4% within SCOT-HEART. All guidelines identified lower rates of obstructive coronary artery disease in low- versus intermediate-high-risk patients with a negative predictive value of ≥0.90. Compared with low-risk groups, all intermediate-high-risk groups had greater risks of coronary revascularization (odds ratio [OR]: 2.2 to 24.1) and clinical outcomes (OR: 1.84 to 5.8). CONCLUSIONS: Compared with risk-based guidelines, symptom-focused assessment identifies a larger group of low-risk chest pain patients potentially deriving limited benefit from noninvasive testing. (Scottish Computed Tomography of the Heart Trial [SCOT-HEART]; NCT01149590; Prospective Multicenter Imaging Study for Evaluation of Chest Pain [PROMISE]; NCT01174550).


Assuntos
Angina Estável/diagnóstico por imagem , Cardiologia/normas , Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Guias de Prática Clínica como Assunto/normas , Idoso , Angina Estável/mortalidade , Angina Estável/terapia , Causas de Morte , Consenso , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Revascularização Miocárdica/normas , Ensaios Clínicos Pragmáticos como Assunto , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Eur J Heart Fail ; 19(5): 652-660, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27647784

RESUMO

AIMS: Haemodynamic-guided heart failure (HF) management effectively reduces decompensation events and need for hospitalizations. The economic benefit of clinical improvement requires further study. METHODS AND RESULTS: An estimate of the cost-effectiveness of haemodynamic-guided HF management was made based on observations published in the randomized, prospective single-blinded CHAMPION trial. A comprehensive analysis was performed including healthcare utilization event rates, survival, and quality of life demonstrated in the randomized portion of the trial (18 months). Markov modelling with Monte Carlo simulation was used to approximate comprehensive costs and quality-adjusted life years (QALYs) from a payer perspective. Unit costs were estimated using the Truven Health MarketScan database from April 2008 to March 2013. Over a 5-year horizon, patients in the Treatment group had average QALYs of 2.56 with a total cost of US$56 974; patients in the Control group had QALYs of 2.16 with a total cost of US$52 149. The incremental cost-effectiveness ratio (ICER) was US$12 262 per QALY. Using comprehensive cost modelling, including all anticipated costs of HF and non-HF hospitalizations, physician visits, prescription drugs, long-term care, and outpatient hospital visits over 5 years, the Treatment group had a total cost of US$212 004 and the Control group had a total cost of US$200 360. The ICER was US$29 593 per QALY. CONCLUSIONS: Standard economic modelling suggests that pulmonary artery pressure-guided management of HF using the CardioMEMS™ HF System is cost-effective from the US-payer perspective. This analysis provides the background for further modelling in specific country healthcare systems and cost structures.


Assuntos
Gerenciamento Clínico , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Hospitalização/economia , Modelos Econômicos , Pressão Propulsora Pulmonar/fisiologia , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Aceitação pelo Paciente de Cuidados de Saúde , Estudos Prospectivos , Qualidade de Vida , Método Simples-Cego , Estados Unidos
10.
Heart ; 103(1): 10-18, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27806987

RESUMO

Myocardial injury is common in patients without acute coronary syndrome, and international guidelines recommend patients with myocardial infarction are classified by aetiology. The universal definition differentiates patients with myocardial infarction due to plaque rupture (type 1) from those due to myocardial oxygen supply-demand imbalance (type 2) secondary to other acute illnesses. Patients with myocardial necrosis, but no symptoms or signs of myocardial ischaemia, are classified as acute or chronic myocardial injury. This classification has not been widely adopted in practice, because the diagnostic criteria for type 2 myocardial infarction encompass a wide range of presentations, and the implications of the diagnosis are uncertain. However, both myocardial injury and type 2 myocardial infarction are common, occurring in more than one-third of all hospitalised patients. These patients have poor short-term and long-term outcomes with two-thirds dead in 5 years. The classification of patients with myocardial infarction continues to evolve, and future guidelines are likely to recognise the importance of identifying coronary artery disease in type 2 myocardial infarction. Clinicians should consider whether coronary artery disease has contributed to myocardial injury, as selected patients are likely to benefit from further investigation and in these patients targeted secondary prevention has the potential to improve outcomes.


Assuntos
Infarto do Miocárdio/classificação , Infarto do Miocárdio/etiologia , Distribuição por Idade , Algoritmos , Biomarcadores/sangue , Humanos , Incidência , Infarto do Miocárdio/epidemiologia , Troponina/sangue
11.
Telemed J E Health ; 22(10): 798-808, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27285946

RESUMO

AIMS: Recently, a permanently implantable wireless system, designed to monitor and manage pulmonary artery (PA) pressures remotely, demonstrated significant reductions in heart failure (HF) hospitalizations in high-risk symptomatic patients, regardless of ejection fraction. The objectives of this study were to simulate the estimated clinical and economic impact in Germany of generalized use of this PA pressure monitoring system considering reductions of HF hospitalizations and the improvement in Quality of Life. MATERIALS AND METHODS: Based on the Prospective Health Technology Assessment approach, we simulated the potential of the widespread application of PA pressure monitoring on the German healthcare system for the period 2009-2021. RESULTS: This healthcare economic simulation formulated input assumptions based on results from the CHAMPION Trial, a multicenter, prospective, randomized controlled U.S. trial that demonstrated a 37% reduction of hospitalizations in persistently symptomatic previous HF patients. Based on these results, an estimated 114,800 hospitalizations would expected to be avoided. This effect would potentially save an estimated €522 million, an equivalent of $575 million, during the entire simulation period. CONCLUSION: This healthcare economic modeling of the PA pressure monitoring system's impact demonstrates substantial clinical and economic benefits in the German healthcare system.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/fisiopatologia , Artéria Pulmonar , Tecnologia de Sensoriamento Remoto/métodos , Telemedicina/métodos , Idoso , Idoso de 80 Anos ou mais , Monitorização Ambulatorial da Pressão Arterial/economia , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Simulação por Computador , Feminino , Alemanha , Hospitalização/economia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Tecnologia de Sensoriamento Remoto/economia , Tecnologia de Sensoriamento Remoto/instrumentação , Telemedicina/economia , Telemedicina/instrumentação
12.
Circ Heart Fail ; 9(6)2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27220593

RESUMO

BACKGROUND: This study examines the impact of pulmonary artery pressure-guided heart failure (HF) care on 30-day readmissions in Medicare-eligible patients. METHODS AND RESULTS: The CardioMicroelectromechanical system (CardioMEMS) Heart Sensor Allows Monitoring of Pressures to Improve Outcomes in New York Heart Association Class III Heart Failure Patients (CHAMPION) Trial included 550 patients implanted with a permanent MEMS-based pressure sensor in the pulmonary artery. Subjects were randomized to a treatment group (uploaded pressures were made available to investigators) or a control group (uploaded pressures were not made available to investigators). This analysis focuses on the 245 Medicare-eligible subjects for whom compliance with daily transmissions was 93% compared with 88% for the overall population. Medications were changed more often in the treatment group using pressure information compared with the control group using symptoms and daily weights alone. During the 515 days follow-up after implant, the overall rate of HF hospitalizations was 49% lower in the treatment group (60 HF hospitalizations, 0.34 events/patient-year) compared with control (117 HF hospitalizations, 0.67 events/patient-year; hazard ratio 0.51, 95% confidence interval 0.37-0.70; P<0.0001). Of the 177 HF hospitalizations, 155 qualified as an index HF hospitalization. All-cause 30-day readmissions were 58% lower in the treatment group (0.07 events/patient-year) compared with 0.18 events/patient-year in the control group (hazard ratio 0.42, 95% confidence interval 0.22-0.80; P=0.0080). CONCLUSIONS: Pulmonary artery pressure-guided HF management in Medicare-eligible patients led to a 49% reduction in total HF hospitalizations and a 58% reduction in all-cause 30-day readmissions. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT00531661.


Assuntos
Pressão Arterial/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial , Fármacos Cardiovasculares/uso terapêutico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Readmissão do Paciente , Artéria Pulmonar/efeitos dos fármacos , Telemetria , Idoso , Idoso de 80 Anos ou mais , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Substituição de Medicamentos , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Medicare , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Fatores de Risco , Telemetria/instrumentação , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento , Estados Unidos , Tecnologia sem Fio
13.
Circulation ; 110(16): 2389-94, 2004 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-15313946

RESUMO

BACKGROUND: Heart rate variability (HRV) as an indirect autonomic assessment provides prognostic information when measured over short time periods in patients with heart failure. Long-term continuous HRV can be measured from an implantable device, but the clinical value of these measurements is unknown. METHODS AND RESULTS: A total of 397 patients with New York Heart Association class III or IV heart failure were studied. Of these, 370 patients had information from their implanted cardiac resynchronization device for mortality risk stratification, and 288 patients had information for measured parameters (ie, HRV, night heart rate, and patient activity) and clinical event analyses. Continuous HRV was measured as the standard deviation of 5-minute median atrial-atrial intervals (SDAAM) sensed by the device. SDAAM <50 ms when averaged over 4 weeks was associated with increased mortality risk (hazard ratio 3.20, P=0.02) and SDAAM were persistently lower over the entire follow-up period in patients who required hospitalization or died. SDAAM decreased a median of 16 days before hospitalization and returned to baseline after treatment. Automated detection of decreases in SDAAM was 70% sensitive in detecting cardiovascular hospitalization, with 2.4 false-positives per patient-year of follow-up. CONCLUSIONS: This study demonstrates that SDAAM continuously measured from an implanted cardiac resynchronization device is lower in patients at high mortality and hospitalization risk. SDAAM declines as patient status decompensates. Continuous long-term SDAAM may be a useful tool in the clinical management of patients with chronic heart failure.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Desfibriladores Implantáveis , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Monitorização Fisiológica , Idoso , Algoritmos , Ritmo Circadiano , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Hospitalização/estatística & dados numéricos , Humanos , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Atividade Motora , Prognóstico , Medição de Risco , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA