Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Echocardiography ; 38(4): 693-696, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33749908

RESUMO

We describe an elderly male patient with two MitraClip devices, one fixed and the other detached, in whom live/real-time three-dimensional echocardiography (3DTEE) provided incremental value and additional information compared to two-dimensional transesophageal echocardiography (2DTEE). 3DTEE offered the ability to comprehensively assess the mitral valve (MV) utilizing full volume and multiplanar reconstruction (MPR) modes. 3DTEE proved useful in assessing the position of the properly attached and the partially detached MitraClip, including assessment of orifice size and degree of mitral regurgitation (MR). In addition, trapping of MV chordae by both clips was noted in the 3DTEE image dataset and confirmed at the time of surgery. Chordal trapping was not detected by 2DTEE. 3DTEE proved useful in more accurately estimating the severity of residual MR with the MitraClips in place since the regurgitant jet vena contracta (VC) could be viewed en face and VC area measured by planimetry in the correct imaging plane as compared to limited linear images from 2DTEE.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Idoso , Ecocardiografia Transesofagiana , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Reprodutibilidade dos Testes
3.
Echocardiography ; 33(8): 1234-8, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27550532

RESUMO

We present two cases in whom live/real time three-dimensional transesophageal echocardiography (3DTEE) provided incremental value in the assessment of atherosclerotic disease in the aorta. In one patient, it identified additional atherosclerotic ulcers as well as thrombi within them which were missed by two-dimensional (2D) TEE. In both cases, the size of the large mobile atherosclerotic plaque was underestimated by 2DTEE as compared with 3DTEE. Furthermore, 3DTEE provided volume quantification of the thrombi and ulcers which is not possible by 2DTEE. The echocardiographic findings of atherosclerotic plaques were confirmed by computed tomography in one patient and by surgery in the other.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Trombose/diagnóstico por imagem , Úlcera/diagnóstico por imagem , Idoso , Sistemas Computacionais , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Echocardiography ; 32(5): 848-54, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25827179

RESUMO

We report a case of a right atrial thrombus traversing a patent foramen ovale into the left atrium, where three-dimensional transesophageal echocardiography provided considerable incremental value over two-dimensional transesophageal echocardiography in its assessment. As well as allowing us to better spatially characterize the thrombus, three-dimensional transesophageal echocardiography provided a more quantitative assessment through estimation of total thrombus burden.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Forame Oval Patente/complicações , Cardiopatias/diagnóstico por imagem , Trombose/complicações , Trombose/diagnóstico por imagem , Idoso , Feminino , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Cardiopatias/complicações , Cardiopatias/cirurgia , Humanos , Trombose/cirurgia
5.
Echocardiography ; 31(7): 895-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24978600

RESUMO

We present an adult patient in whom live/real time three-dimensional transesophageal echocardiography (3DTEE) provided incremental value in the assessment of the spinal cord as compared to two-dimensional transesophageal echocardiographic (2DTEE) findings published in the literature. It improved accurate identification and assessment of the anterior radiculomedullary spinal arteries which may have an important clinical application in monitoring for spinal cord ischemia during thoracic aortic surgery. Because the spinal cord and spinal canal could be examined using not only transverse but also coronal (frontal), sagittal, and oblique planes, 3DTEE further allowed for three-dimensional measurements of the dimensions and volumetric analysis of the visualized spinal cord and spinal canal. These may have implications in the assessment of spinal cord edema due to trauma and other conditions which result in increase in the size and volume of the spinal cord.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Monitorização Intraoperatória/métodos , Medula Espinal/diagnóstico por imagem , Aorta Torácica/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medula Espinal/irrigação sanguínea , Isquemia do Cordão Espinal/prevenção & controle
7.
Echocardiography ; 31(4): 531-3, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24646027

RESUMO

Accurate echocardiographic evaluation of the pulmonary valve is technically difficult because of its close proximity to the left lung, which often limits decision making. Pulmonary valvotomy is the intervention of choice for symptomatic pulmonary valve stenosis, but fluoroscopy lacks appropriate real time anatomic detail. In this report, we present a case where direct imaging of the pulmonary valve with live/real time three-dimensional transesophageal echocardiography (3DTEE) aided in accurate evaluation and was then used to help guide and monitor successful valvuloplasty of a stenotic pulmonary valve bioprosthesis. We demonstrate that even in cases where two-dimensional (2D) evaluation of the pulmonary valve is difficult, the use of live/real time 3DTEE allows for accurate evaluation of bioprosthetic pulmonary valve structure and function, and enhances the precision and monitoring of percutaneous valvuloplasty.


Assuntos
Bioprótese , Ecocardiografia Tridimensional/estatística & dados numéricos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Cateterismo Cardíaco , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Falha de Prótese , Estenose da Valva Pulmonar/congênito , Reoperação/métodos , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
8.
Am J Cardiol ; 111(7): 1067-72, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23332597

RESUMO

How the left ventricle remodels in response to a high-volume stimulus is important in evaluating the endurance athlete's heart. Marathoners and patients with isolated, moderate chronic compensated mitral regurgitation (MR) represent physiologic and pathologic forms of eccentric left ventricular (LV) remodeling in response to intermittent and chronic volume overload, respectively. Thus, in this study, magnetic resonance imaging with tissue tagging and 3-dimensional data analysis at rest were performed in 19 marathoners (mean age 39 ± 10 years, 47% women), 17 patients with isolated MR without coronary artery disease or medical therapy (mean age 46 ± 5 years, 53% women), and 24 controls (mean age 45 ± 8 years, 50% women). Marathoners and patients with MR had approximately 35% greater LV end-diastolic volume indexes, approximately 50% greater end-systolic volume indexes, and approximately 34% greater LV stroke volume indexes (p <0.0001) compared to controls. However, marathoners' hearts had increased long-axis length, while those of patients with MR did not differ from the hearts of controls. The hearts of patients with MR had greater LV global and apex sphericity compared to those of marathoners and controls (p <0.0001). Marathoners had normal LV mass/volume ratios and wall thicknesses, whereas these were significantly decreased in the MR group. In marathoners, the baseline LV work rate was similar to that in controls and higher in patients with MR compared to controls. In conclusion, marathoners' hearts achieve elevated stroke volume at rest with adherence to an elliptical shape defined by 3-dimensional geometry and mass/volume ratio. Thus, a comprehensive evaluation of LV geometry and mass/volume ratio may be important in the evaluation of the athlete's heart.


Assuntos
Cardiomegalia Induzida por Exercícios/fisiologia , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Resistência Física/fisiologia , Corrida/fisiologia , Adulto , Análise de Variância , Estudos de Casos e Controles , Ecocardiografia Doppler , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Software
9.
J Am Geriatr Soc ; 58(12): 2323-8, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21143440

RESUMO

OBJECTIVES: To understand the potential roles of various patient and provider factors in the underuse of pneumococcal vaccination in Medicare-eligible older African Americans. DESIGN: The Cardiovascular Health Study. SETTING: Four U.S. states. PARTICIPANTS: Seven hundred ninety-five pairs of community-dwelling Medicare-eligible African-American and white adults aged 65 and older, balanced according to age and sex. MEASUREMENTS: Data on self-reported race, receipt of pneumococcal vaccination, and other important sociodemographic and clinical variables were collected at baseline. RESULTS: Participants had a mean age ± standard deviation of 73 ± 6; 63% were female. Pneumococcal vaccination rates were 22% for African Americans and 28% for whites (unadjusted odds ratios (OR) for African Americans=0.75; 95% confidence interval (CI)=0.60-0.94; P=.01). This association remained significant despite adjustment for sociodemographic and clinical confounders, including education, income, chronic obstructive pulmonary disease, and prior pneumonia (OR=0.74, 95% CI=0.56-0.97; P=.03), but the association was no longer significant after additional adjustment for the receipt of influenza vaccination (OR=0.79, 95% CI=0.59-1.06; P=.12). Receipt of influenza vaccination was associated with higher odds of receiving pneumococcal vaccination (unadjusted OR=6.43, 95% CI=5.00-8.28; P<.001), and the association between race and pneumococcal vaccination lost significance when adjusted for influenza vaccination alone (OR=0.81, 95% CI=0.63-1.03; P=.09). CONCLUSION: The strong association between receipt of influenza and pneumococcal vaccinations suggests that patient and provider attitudes toward vaccination, rather than traditional confounders such as education and income, may help explain the underuse of pneumococcal vaccination in older African Americans.


Assuntos
Negro ou Afro-Americano/estatística & dados numéricos , Aceitação pelo Paciente de Cuidados de Saúde/etnologia , Vacinas Pneumocócicas/administração & dosagem , Pneumonia Bacteriana/prevenção & controle , População Branca/estatística & dados numéricos , Idoso , Estudos de Coortes , Intervalos de Confiança , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Programas de Imunização , Vacinas contra Influenza/administração & dosagem , Influenza Humana/prevenção & controle , Masculino , Medicare/estatística & dados numéricos , Razão de Chances , Pneumonia Bacteriana/etnologia , Características de Residência , Fatores de Risco , Inquéritos e Questionários , Estados Unidos/epidemiologia , Vacinação/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA