Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Iowa Orthop J ; 43(2): 60-69, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38213860

RESUMO

Background: Extremity soft-tissue sarcomas (STS) are commonly treated with neoadjuvant radiation therapy followed by surgical resection. However, the pathological near-complete response rate is low (9-25%). Noninvasive imaging assessment that predicts treatment response before and during treatment is desirable to optimize treatment regimens. This pilot study aimed to investigate the application of a quantitative MRI parameter, T2*, in assessing neoadjuvant radiation therapy combined with pharmacological ascorbate in extremity STS. Methods: This prospective cohort study included seven patients diagnosed with extremity STS and scheduled to receive neoadjuvant radiation therapy combined with pharmacological ascorbate. T2* maps were obtained from each patient before treatment (baseline MRI), two weeks after initiating treatment (on-treatment MRI), and before surgery (pre-surgery MRI). The T2* values within the tumor region were transformed into z-scores with respect to the normal- appearing tissue region. The voxel-wise z-scores within the tumor region were thresholded to generate masks representing significantly high (z-score>1.96) and low z-score (z-score<-1.96) voxels. The means of the total z-scores and within each of the significantly high and low z-score mask were computed. Their correlations with percent necrosis from pathological examination were evaluated using Spearman's rank correlation coefficient r. A correlation was considered as moderate or strong when r is higher than 0.6 and 0.8, respectively. A correlation was considered as fair or weak when r is below 0.6. Results: For the baseline and on-treatment MRIs, the means of the significantly high z-scores of the T2* measurements showed moderate correlations with percent necrosis (r = 0.68 and 0.6; p = 0.11 and 0.24). For the pre-surgery MRI, the means of the total and significantly high z-scores showed strong correlations with percent necrosis (r = 0.8 and 0.9; p = 0.13 and 0.08). Tumor volume and baseline MRI-based percent necrosis showed fair or weak correlations (r = 0.3-0.54; p = 0.24-0.68). Conclusion: T2* measurements prior to treatment, two weeks after initiating treatment, and before surgery showed moderate to strong correlations with percent necrosis. These results support the potential for using T2* mapping to predict and assess response to neoadjuvant radiation therapy combined with pharmacological ascorbate in extremity STS. Level of Evidence: IV.


Assuntos
Sarcoma , Neoplasias de Tecidos Moles , Humanos , Terapia Neoadjuvante , Projetos Piloto , Estudos Prospectivos , Sarcoma/diagnóstico por imagem , Sarcoma/tratamento farmacológico , Sarcoma/radioterapia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/tratamento farmacológico , Neoplasias de Tecidos Moles/radioterapia , Necrose
2.
Med Phys ; 49(4): 2684-2698, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35120278

RESUMO

PURPOSE: The radiobiological benefits afforded by spatially fractionated (GRID) radiation therapy pairs well with the dosimetric advantages of proton therapy. Inspired by the emergence of energy-layer specific collimators in pencil beam scanning (PBS), this work investigates how the spot spacing and collimation can be optimized to maximize the therapeutic gains of a GRID treatment while demonstrating the integration of a dynamic collimation system (DCS) within a commercial beamline to deliver GRID treatments and experimentally benchmark Monte Carlo calculation methods. METHODS: GRID profiles were experimentally benchmarked using a clinical DCS prototype that was mounted to the nozzle of the IBA-dedicated nozzle system. Integral depth dose (IDD) curves and lateral profiles were measured for uncollimated and GRID-collimated beamlets. A library of collimated GRID dose distributions were simulated by placing beamlets within a specified uniform grid and weighting the beamlets to achieve a volume-averaged tumor cell survival equivalent to an open field delivery. The healthy tissue sparing afforded by the GRID distribution was then estimated across a range of spot spacings and collimation widths, which were later optimized based on the radiosensitivity of the tumor cell line and the nominal spot size of the PBS system. This was accomplished by using validated models of the IBA universal and dedicated nozzles. RESULTS: Excellent agreement was observed between the measured and simulated profiles. The IDDs matched above 98.7% when analyzed using a 1%/1-mm gamma criterion with some minor deviation observed near the Bragg peak for higher beamlet energies. Lateral profile distributions predicted using Monte Carlo methods agreed well with the measured profiles; a gamma passing rate of 95% or higher was observed for all in-depth profiles examined using a 3%/2-mm criteria. Additional collimation was shown to improve PBS GRID treatments by sharpening the lateral penumbra of the beamlets but creates a trade-off between enhancing the valley-to-peak ratio of the GRID delivery and the dose-volume effect. The optimal collimation width and spot spacing changed as a function of the tumor cell radiosensitivity, dose, and spot size. In general, a spot spacing below 2.0 cm with a collimation less than 1.0 cm provided a superior dose distribution among the specific cases studied. CONCLUSIONS: The ability to customize a GRID dose distribution using different collimation sizes and spot spacings is a useful advantage, especially to maximize the overall therapeutic benefit. In this regard, the capabilities of the DCS, and perhaps alternative dynamic collimators, can be used to enhance GRID treatments. Physical dose models calculated using Monte Carlo methods were experimentally benchmarked in water and were found to accurately predict the respective dose distributions of uncollimated and DCS-collimated GRID profiles.


Assuntos
Terapia com Prótons , Método de Monte Carlo , Terapia com Prótons/métodos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
3.
Radiat Res ; 195(3): 230-234, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347596

RESUMO

MR-linac technology enhances the precision of therapeutic radiation by clarifying the tumor-normal tissue interface and provides the potential for adaptive treatment planning. Accurate delineation of tumors on diagnostic magnetic resonance imaging (MRI) frequently requires gadolinium-based contrast agents (GBCAs). Despite generally being considered safe, previous literature suggests that GBCAs are capable of contrast-induced acute kidney injury (AKI). It is unclear if the risk for AKI is enhanced when GBCAs are administered concurrently with ionizing radiotherapy. During irradiation, gadolinium may be liberated from its chelator which may induce AKI. The goal of this work was to determine if radiation combined with GBCAs increased the incidence of AKI. Using a preclinical MRI-guided irradiation system, where MRI acquisitions and radiation delivery are performed in rapid succession, tumor-bearing mice with normal kidney function were injected with GBCA and treated with 2, 8 or 18 Gy irradiation. Renal function was assessed on days three and seven postirradiation to assess for AKI. No clinically relevant changes in blood urea nitrogen and creatinine were observed in any combination of GBCA and radiation dose. From these data, we conclude that GBCA in combination with radiation does not increase the risk for AKI in mice. Additional investigation of multiple doses of GBCA administered concurrently with irradiation is warranted to evaluate the risk of chronic kidney injury.


Assuntos
Injúria Renal Aguda/diagnóstico por imagem , Meios de Contraste/farmacologia , Compostos Organometálicos/farmacologia , Radiação Ionizante , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/fisiopatologia , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos dos fármacos , Encéfalo/patologia , Encéfalo/efeitos da radiação , Meios de Contraste/efeitos adversos , Modelos Animais de Doenças , Gadolínio/efeitos adversos , Gadolínio/farmacologia , Humanos , Rim/diagnóstico por imagem , Rim/efeitos dos fármacos , Rim/patologia , Rim/efeitos da radiação , Imageamento por Ressonância Magnética , Camundongos , Compostos Organometálicos/efeitos adversos , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia Guiada por Imagem/métodos
4.
Radiat Res ; 191(6): 491-496, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31039080

RESUMO

Based on encouraging results from several early-phase clinical trials, there is renewed interest in the use of pharmacological ascorbate (i.e., intravenous administration resulting in >≈10 mM plasma ascorbate concentrations) in combination with standard-of-care cancer treatments including radiation and/or chemotherapy. Under normal, healthy physiological conditions, humans maintain plasma ascorbate concentrations in the range of 40-80 lM. However, in vivo antitumor activity requires supraphysiological plasma concentrations on the order of ≈20 mM. The stability of ascorbate in whole blood has been well studied. The goal of this work was to determine the appropriate handling methods of blood samples, after treatment with pharmacological ascorbate, which allow for the optimal measurement of ascorbate in plasma for dosing verification. Our findings indicate that ascorbate concentrations (mM) are relatively stable in whole blood collected in sodium heparin tubes and stored on ice (or at 4°C) for up to 24 h. After 24 h, ascorbate levels in plasma are relatively stable at 4°C for up to 72 h. At -20°C, plasma concentrations are relatively stable for 2-3 weeks, while at -80°C, ascorbate concentrations in plasma are stable for at least one month. In contrast, patient samples showed better stability when stored as whole blood compared to plasma at 4°C but increasing hemolysis over time may significantly skew ascorbate measurements. Additionally, patient samples can be reliably stored as plasma at -20°C for up to three weeks in either a frost-containing or frost-free environment. This information can guide the collection, processing and storage of clinical samples after pharmacological ascorbate infusions amenable to multi-center clinical trials.


Assuntos
Ácido Ascórbico/sangue , Coleta de Amostras Sanguíneas/métodos , Ensaios Clínicos como Assunto , Temperatura Baixa , Feminino , Humanos , Masculino , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA