Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med Sci ; 19(3): 235-246, 2020 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-32655086

RESUMO

PURPOSE: To characterize the non-laminar flow dynamics and resultant decreased wall shear stress (WSS) and high oscillatory shear index (OSI) of the infrarenal abdominal aortic dilatation, cardiac phase-resolved 3D phase-contrast MRI (4D-flow MRI) was performed. METHODS: The prospective single-arm study was approved by the Institutional Review Board and included 18 subjects (median 67.5 years) with the dilated infrarenal aorta (median diameter 35 mm). 4D-flow MRI was conducted on a 1.5T MRI system. On 3D streamline images, laminar and non-laminar (i.e., vortex or helical) flow patterns were visually assessed both for the dilated aorta and for the undilated upstream aorta. Cardiac phase-resolved flow velocities, WSS and OSI, were also measured for the dilated aorta and the upstream undilated aorta. RESULTS: Non-laminar flow represented by vortex or helical flow was more frequent and overt in the dilated aorta than in the undilated upstream aorta (P < 0.0156) with a very good interobserver agreement (weighted kappa: 0.82-1.0). The WSS was lower, and the OSI was higher on the dilated aortic wall compared with the proximal undilated segments. In mid-systole, mean spatially-averaged WSS was 0.20 ± 0.016 Pa for the dilated aorta vs. 0.68 ± 0.071 Pa for undilated upstream aorta (P < 0.0001), and OSI on the dilated aortic wall was 0.093 ± 0.010 vs. 0.041 ± 0.0089 (P = 0.013). The maximum values and the amplitudes of the WSS at the dilated aorta were inversely proportional to the ratio of dilated/undilated aortic diameter (r = -0.694, P = 0.0014). CONCLUSION: 4D-flow can characterize abnormal non-laminar flow dynamics within the dilated aorta in vivo. The wall of the infrarenal aortic dilatation is continuously and increasingly affected by atherogenic stimuli due to the flow disturbances represented by vortex or helical flow, which is reflected by lower WSS and higher OSI.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Magn Reson Imaging ; 52(6): 1688-1698, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32452088

RESUMO

BACKGROUND: Quantitative T2 * MRI is the standard of care for the assessment of iron overload. However, patient motion corrupts T2 * estimates. PURPOSE: To develop and evaluate a motion-robust, simultaneous cardiac and liver T2 * imaging approach using non-Cartesian, rosette sampling and a model-based reconstruction as compared to clinical-standard Cartesian MRI. STUDY TYPE: Prospective. PHANTOM/POPULATION: Six ferumoxytol-containing phantoms (26-288 µg/mL). Eight healthy subjects and 18 patients referred for clinically indicated iron overload assessment. FIELD STRENGTH/SEQUENCE: 1.5T, 2D Cartesian and rosette gradient echo (GRE) ASSESSMENT: GRE T2 * values were validated in ferumoxytol phantoms. In healthy subjects, test-retest and spatial coefficient of variation (CoV) analysis was performed during three breathing conditions. Cartesian and rosette T2 * were compared using correlation and Bland-Altman analysis. Images were rated by three experienced radiologists on a 5-point scale. STATISTICAL TESTS: Linear regression, analysis of variance (ANOVA), and paired Student's t-testing were used to compare reproducibility and variability metrics in Cartesian and rosette scans. The Wilcoxon rank test was used to assess reader score comparisons and reader reliability was measured using intraclass correlation analysis. RESULTS: Rosette R2* (1/T2 *) was linearly correlated with ferumoxytol concentration (r2 = 1.00) and not significantly different than Cartesian values (P = 0.16). During breath-holding, ungated rosette liver and heart T2 * had lower spatial CoV (liver: 18.4 ± 9.3% Cartesian, 8.8% ± 3.4% rosette, P = 0.02, heart: 37.7% ± 14.3% Cartesian, 13.4% ± 1.7% rosette, P = 0.001) and higher-quality scores (liver: 3.3 [3.0-3.6] Cartesian, 4.7 [4.1-4.9] rosette, P = 0.005, heart: 3.0 [2.3-3] Cartesian, 4.5 [3.8-5.0] rosette, P = 0.005) compared to Cartesian values. During free-breathing and failed breath-holding, Cartesian images had very poor to average image quality with significant artifacts, whereas rosette remained very good, with minimal artifacts (P = 0.001). DATA CONCLUSION: Rosette k-sampling with a model-based reconstruction offers a clinically useful motion-robust T2 * mapping approach for iron quantification. J. MAGN. RESON. IMAGING 2020;52:1688-1698.


Assuntos
Óxido Ferroso-Férrico/análise , Coração/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Artefatos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Movimento (Física) , Imagens de Fantasmas , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
3.
J Magn Reson Imaging ; 49(7): e195-e204, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30637847

RESUMO

BACKGROUND: MRI is commonly used to evaluate pediatric musculoskeletal pathologies, but same-day/near-term scheduling and short exams remain challenges. PURPOSE: To investigate the feasibility of a targeted rapid pediatric knee MRI exam, with the goal of reducing cost and enabling same-day MRI access. STUDY TYPE: A cost effectiveness study done prospectively. SUBJECTS: Forty-seven pediatric patients. FIELD STRENGTH/SEQUENCE: 3T. The 10-minute protocol was based on T2 Shuffling, a four-dimensional acquisition and reconstruction of images with variable T2 contrast, and a T1 2D fast spin-echo (FSE) sequence. A distributed, compressed sensing-based reconstruction was implemented on a four-node high-performance compute cluster and integrated into the clinical workflow. ASSESSMENT: In an Institutional Review Board-approved study with informed consent/assent, we implemented a targeted pediatric knee MRI exam for assessing pediatric knee pain. Pediatric patients were subselected for the exam based on insurance plan and clinical indication. Over a 2-year period, 47 subjects were recruited for the study and 49 MRIs were ordered. Date and time information was recorded for MRI referral, registration, and completion. Image quality was assessed from 0 (nondiagnostic) to 5 (outstanding) by two readers, and consensus was subsequently reached. STATISTICAL TESTS: A Wilcoxon rank-sum test assessed the null hypothesis that the targeted exam times compared with conventional knee exam times were unchanged. RESULTS: Of the 49 cases, 20 were completed on the same day as exam referral. Median time from registration to exam completion was 18.7 minutes. Median reconstruction time for T2 Shuffling was reduced from 18.9 minutes to 95 seconds using the distributed implementation. Technical fees charged for the targeted exam were one-third that of the routine clinical knee exam. No subject had to return for additional imaging. DATA CONCLUSION: The targeted knee MRI exam is feasible and reduces the imaging time, cost, and barrier to same-day MRI access for pediatric patients. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2019.


Assuntos
Traumatismos do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Adolescente , Criança , Análise Custo-Benefício , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Traumatismos do Joelho/economia , Masculino , Variações Dependentes do Observador , Estudos Prospectivos
4.
J Magn Reson Imaging ; 49(7): e183-e194, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30582251

RESUMO

BACKGROUND: Clinical knee MRI protocols require upwards of 15 minutes of scan time. PURPOSE/HYPOTHESIS: To compare the imaging appearance of knee abnormalities depicted with a 5-minute 3D double-echo in steady-state (DESS) sequence with separate echo images, with that of a routine clinical knee MRI protocol. A secondary goal was to compare the imaging appearance of knee abnormalities depicted with 5-minute DESS paired with a 2-minute coronal proton-density fat-saturated (PDFS) sequence. STUDY TYPE: Prospective. SUBJECTS: Thirty-six consecutive patients (19 male) referred for a routine knee MRI. FIELD STRENGTH/SEQUENCES: DESS and PDFS at 3T. ASSESSMENT: Five musculoskeletal radiologists evaluated all images for the presence of internal knee derangement using DESS, DESS+PDFS, and the conventional imaging protocol, and their associated diagnostic confidence of the reading. STATISTICAL TESTS: Differences in positive and negative percent agreement (PPA and NPA, respectively) and 95% confidence intervals (CIs) for DESS and DESS+PDFS compared with the conventional protocol were calculated and tested using exact McNemar tests. The percentage of observations where DESS or DESS+PDFS had equivalent confidence ratings to DESS+Conv were tested with exact symmetry tests. Interreader agreement was calculated using Krippendorff's alpha. RESULTS: DESS had a PPA of 90% (88-92% CI) and NPA of 99% (99-99% CI). DESS+PDFS had increased PPA of 99% (95-99% CI) and NPA of 100% (99-100% CI) compared with DESS (both P < 0.001). DESS had equivalent diagnostic confidence to DESS+Conv in 94% of findings, whereas DESS+PDFS had equivalent diagnostic confidence in 99% of findings (both P < 0.001). All readers had moderate concordance for all three protocols (Krippendorff's alpha 47-48%). DATA CONCLUSION: Both 1) 5-minute 3D-DESS with separated echoes and 2) 5-minute 3D-DESS paired with a 2-minute coronal PDFS sequence depicted knee abnormalities similarly to a routine clinical knee MRI protocol, which may be a promising technique for abbreviated knee MRI. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Articulação do Joelho/diagnóstico por imagem , Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prótons , Radiologia , Reprodutibilidade dos Testes
5.
Sci Rep ; 7(1): 5330, 2017 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-28706270

RESUMO

Diagnostic testing often assesses the cardiovascular or respiratory systems in isolation, ignoring the major pathophysiologic interactions between the systems in many diseases. When both systems are assessed currently, multiple modalities are utilized in costly fashion with burdensome logistics and decreased accessibility. Thus, we have developed a new acquisition and reconstruction paradigm using the flexibility of MRI to enable a comprehensive exam from a single 5-15 min scan. We constructed a compressive-sensing approach to pseudo-randomly acquire highly subsampled, multi-dimensionally-encoded and time-stamped data from which we reconstruct volumetric cardiac and respiratory motion phases, contrast-agent dynamics, and blood flow velocity fields. The proposed method, named XD flow, is demonstrated for (a) evaluating congenital heart disease, where the impact of bulk motion is reduced in a non-sedated neonatal patient and (b) where the observation of the impact of respiration on flow is necessary for diagnostics; (c) cardiopulmonary imaging, where cardiovascular flow, function, and anatomy information is needed along with pulmonary perfusion quantification; and in (d) renal function imaging, where blood velocities and glomerular filtration rates are simultaneously measured, which highlights the generality of the technique. XD flow has the ability to improve quantification and to provide additional data for patient diagnosis for comprehensive evaluations.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Circulação Pulmonar/fisiologia , Sistema Respiratório/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Humanos , Sistema Respiratório/anatomia & histologia
6.
J Magn Reson Imaging ; 44(2): 383-92, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26871420

RESUMO

PURPOSE: To compare the precision and interobserver agreement of ventricular volume, function, and mass quantification by 3D time-resolved (4D) flow MRI relative to cine steady-state free precession (SSFP). MATERIALS AND METHODS: With Institutional Research Board approval, informed consent, and HIPAA compliance, 22 consecutive patients with congenital heart disease (CHD) (10 males, 6.4 ± 4.8 years) referred for 3T ferumoxytol-enhanced cardiac MRI were prospectively recruited. Complete ventricular coverage with standard 2D short-axis cine SSFP and whole chest coverage with axial 4D flow were obtained. Two blinded radiologists independently segmented images for left ventricular (LV) and right ventricular (RV) myocardium at end systole (ES) and end diastole (ED). Statistical analysis included linear regression, analysis of variance (ANOVA), Bland-Altman (BA) analysis, and intraclass correlation (ICC). RESULTS: Significant positive correlations were found between 4D flow and SSFP for ventricular volumes (r = 0.808-0.972, P < 0.001), ejection fraction (EF) (r = 0.900-928, P < 0.001), and mass (r = 0.884-0.934, P < 0.001). BA relative limits of agreement for both ventricles were between -52% to 34% for volumes, -29% to 27% for EF, and -41% to 48% for mass, with wider limits of agreement for the RV compared to the LV. There was no significant difference between techniques with respect to mean square difference of ED-ES mass for either LV (F = 2.05, P = 0.159) or RV (F = 0.625, P = 0.434). Interobserver agreement was moderate to good with both 4D flow (ICC 0.523-0.993) and SSFP (ICC 0.619-0.982), with overlapping confidence intervals. CONCLUSION: Quantification of ventricular volume, function, and mass can be accomplished with 4D flow MRI with precision and interobserver agreement comparable to that of cine SSFP. J. Magn. Reson. Imaging 2016;44:383-392.


Assuntos
Óxido Ferroso-Férrico , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/fisiopatologia
7.
J Magn Reson Imaging ; 42(4): 870-86, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25708923

RESUMO

With improvements in surgical and medical management, patients with congenital heart disease (CHD) are often living well into adulthood. MRI provides critical data for diagnosis and monitoring of these patients, yielding information on cardiac anatomy, blood flow, and cardiac function. Though historically these exams have been complex and lengthy, four-dimensional (4D) flow is emerging as a single fast technique for comprehensive assessment of CHD. The 4D flow consists of a volumetric time-resolved acquisition that is gated to the cardiac cycle, providing a time-varying vector field of blood flow as well as registered anatomic images. In this article, we provide an overview of MRI evaluation of congenital heart disease by means of example of three relatively common representative conditions: tetralogy of Fallot, aortic coarctation, and anomalous pulmonary venous drainage. Then 4D flow data acquisition, data correction, and postprocessing techniques are reviewed. We conclude with several examples that highlight the comprehensive nature of the evaluation of congenital heart disease with 4D flow.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Cardiopatias Congênitas/diagnóstico , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Algoritmos , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
AJR Am J Roentgenol ; 198(3): W250-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22358022

RESUMO

OBJECTIVE: The quantification of cardiac flow and ventricular volumes is an essential goal of many congenital heart MRI examinations, often requiring acquisition of multiple 2D phase-contrast and bright-blood cine steady-state free precession (SSFP) planes. Scan acquisition, however, is lengthy and highly reliant on an imager who is well-versed in structural heart disease. Although it can also be lengthy, 3D time-resolved (4D) phase-contrast MRI yields global flow patterns and is simpler to perform. We therefore sought to accelerate 4D phase contrast and to determine whether equivalent flow and volume measurements could be extracted. MATERIALS AND METHODS: Four-dimensional phase contrast was modified for higher acceleration with compressed sensing. Custom software was developed to process 4D phase-contrast images. We studied 29 patients referred for congenital cardiac MRI who underwent a routine clinical protocol, including cine short-axis stack SSFP and 2D phase contrast, followed by contrast-enhanced 4D phase contrast. To compare quantitative measurements, Bland-Altman analysis, paired Student t tests, and F tests were used. RESULTS: Ventricular end-diastolic, end-systolic, and stroke volumes obtained from 4D phase contrast and SSFP were well correlated (ρ = 0.91-0.95; r(2) = 0.83-0.90), with no statistically significant difference. Ejection fractions were well correlated in a subpopulation that underwent higher-resolution compressed-sensing 4D phase contrast (ρ = 0.88; r(2) = 0.77). Four-dimensional phase contrast and 2D phase contrast flow rates were also well correlated (ρ = 0.90; r(2) = 0.82). Excluding ventricles with valvular insufficiency, cardiac outputs derived from outlet valve flow and stroke volumes were more consistent by 4D phase contrast than by 2D phase contrast and SSFP. CONCLUSION: Combined parallel imaging and compressed sensing can be applied to 4D phase contrast. With custom software, flow and ventricular volumes may be extracted with comparable accuracy to SSFP and 2D phase contrast. Furthermore, cardiac outputs were more consistent by 4D phase contrast.


Assuntos
Cardiopatias Congênitas/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Criança , Pré-Escolar , Meios de Contraste , Feminino , Gadolínio , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Masculino , Compostos Organometálicos , Estudos Retrospectivos , Volume Sistólico
9.
Magn Reson Med ; 67(4): 1086-96, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22179942

RESUMO

T(2) mapping and diffusion-weighted imaging complement morphological imaging for assessing cartilage disease and injury. The double echo steady state sequence has been used for morphological imaging and generates two echoes with markedly different T(2) and diffusion weighting. Modifying the spoiler gradient area and flip angle of the double echo steady state sequence allows greater control of the diffusion weighting of both echoes. Data from two acquisitions with different spoiler gradient areas and flip angles are used to simultaneously estimate the T(2) and apparent diffusion coefficient of each voxel. This method is verified in phantoms and validated in vivo in the knee; estimates from different regions of interest in the phantoms and cartilage are compared to those obtained using standard spin-echo methods. The Pearson correlations were 0.984 for T(2) (∼2% relative difference between spin-echo and double echo steady state estimates) and 0.997 for apparent diffusion coefficient (˜1% relative difference between spin-echo and double echo steady state estimates) for the phantom study and 0.989 for T(2) and 0.987 for apparent diffusion coefficient in regions of interest in the human knee in vivo. High accuracy for simultaneous three-dimensional T(2) and apparent diffusion coefficient measurements are demonstrated, while also providing morphologic three-dimensional images without blurring or distortion in reasonable scan times.


Assuntos
Cartilagem Articular/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Adulto , Cartilagem Articular/patologia , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Modelos Lineares , Masculino , Método de Monte Carlo , Osteoartrite do Joelho/patologia , Imagens de Fantasmas , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA