RESUMO
INTRODUCTION: Drug-eluting stents (DES) reduce the risk of restenosis after percutaneous coronary intervention. The aim of the study was to evaluate, by intravascular ultrasound (IVUS), the minimum lumen area site in the stented segment and the distribution of intimal hyperplasia in patients presenting with a DES or bare-metal stent (BMS) in-stent restenosis. METHODS: The "Nordic Intravascular Ultrasound Study (NIVUS)" study was conducted in Nordic and Baltic countries as a prospective multicenter registry. Two hundred nine patients (DES n=121 and BMS n=88) with in-stent restenosis were enrolled. RESULTS: At the minimum lumen area site in the stented segment, the stent area (5.8±2.2mm2 vs. 7.6±2.4mm2, p<0.001) and intimal hyperplasia area (2.6±2.0mm2 vs. 5.0±2.2mm2, p<0.001) were significantly lower in patients treated with DES compared to BMS. The percentage of stents that did not have a minimum stent area of at least 5.0mm2 (under expansion) was higher in DES (58.7% vs. 37.7%, p=0.008) compared to BMS. Intimal hyperplasia covered 55.4±33.3% of the stent length in the DES compared to 90.7±17.4% in the BMS group, p<0.001. Focal in-stent restenosis was more often seen in DES treated patients compared to BMS treated patients (DES n=84 (59.9%) vs. BMS n=15 (17.0%), p<0.001). CONCLUSION: Stent underexpansion was more often seen in DES than BMS in-stent restenosis. DES more often had focal in-stent restenosis with less intimal hyperplasia.
Assuntos
Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Metais , Neointima , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Proliferação de Células , Reestenose Coronária/etiologia , Reestenose Coronária/patologia , Vasos Coronários/patologia , Feminino , Humanos , Hiperplasia , Letônia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Países Escandinavos e Nórdicos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de IntervençãoRESUMO
BACKGROUND: Stenting-induced edge dissections (ED) can be assessed in detail by optical coherence tomography (OCT). This study sought to investigate the incidence, morphological characteristics, and spontaneous healing course of OCT-identified EDs following drug-eluting stent (DES) implantation in a non-ST segment elevation myocardial infarction (NSTEMI) patient-population. METHODS: Acute vessel wall injury at the 5-mm stent adjacent distal and proximal reference segments was assessed by post-procedure OCT and intravascular ultrasound (IVUS) in n=97 NSTEMI-patients (n=97 lesions). Six months OCT follow-up was available in 82 patients (including 35 untreated post-procedure EDs). RESULTS: The overall incidence of post-procedure OCT-detected ED was 38 per 97 patients (39.2%), and 47 per 182 stent edges (25.8%). None of the EDs were angiographically visualizable, while 10 (21.3%) were visible on concomitant IVUS-analysis. Morphologically, there was a significant difference in plaque type present at ED-edges vs. non-ED-edges when assessed with OCT; (1) lipid-rich and calcified plaques: 80.9% vs. 57.0%, (2) fibrous plaques: 17.0% vs. 26.7%, and (3) normal coronary vessels: 2.1% vs. 16.3%, p<0.01. Plaqueburden, assessed by IVUS, was substantially larger at ED-containing borders: 54.5±10.0% vs. 43.7±11.6%, p=0.01. Three dissections (8.6%) were incompletely healed at 6-month OCT follow-up. None of the EDs caused cardiac events during the 6-month follow-up, however, 1 ED-patient had target lesion revascularization with PCI and DES-implantation in extension of the scheduled OCT-control. CONCLUSIONS: OCT-detected EDs were frequent after stent implantation due to NSTEMI, and the majority of these EDs healed without leading to an adverse prognosis at 6months.
Assuntos
Doença da Artéria Coronariana/epidemiologia , Vasos Coronários/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Stents/efeitos adversos , Tomografia de Coerência Óptica/métodos , Lesões do Sistema Vascular/diagnóstico , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Vasos Coronários/lesões , Dinamarca/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Complicações Pós-Operatórias , Prognóstico , Estudos Prospectivos , Remissão Espontânea , Resultado do Tratamento , Ultrassonografia de Intervenção , Lesões do Sistema Vascular/epidemiologia , Lesões do Sistema Vascular/etiologiaRESUMO
PURPOSE: Frequency-domain optical coherence tomography (FD-OCT) is a high-resolution imaging tool (~10-15 µm), which enables near-histological in-vivo images of the coronary vessel wall. The use of the technique is increasing, both for research- and clinical purposes. This study sought to investigate the intra- and interobserver reliability, as well as the intra-catheter reproducibility of quantitative FD-OCT-assessment of morphometric stent parameters and qualitative FD-OCT-evaluation of strut coverage in 10 randomly selected 6-month follow-up Nobori® biolimus-eluting stents (N-BESs). METHODS: Ten N-BESs (213 cross sectional areas (CSAs) and 1897 struts) imaged with OCT 6 months post-implantation were randomly selected and analyzed by 2 experienced analysts, and the same 10 N-BESs were analyzed by one of the analysts 3 months later. Further, 2 consecutive pullbacks randomly performed in another 10 N-BESs (219 CSAs and 1860 struts) were independently assessed by one of the analysts. RESULTS: The intraobserver variability with regard to relative difference of mean luminal area and mean stent area at the CSA-level was very low: 0.1%±1.4% and 0.5%±3.2%. Interobserver variability also proved to be low: -2.1%±3.3% and 2.1%±4.6%, and moreover, very restricted intra-catheter variation was observed: 0.02%±6.8% and -0.18%±5.2%. The intraobserver-, interobserver- and intra-catheter reliability for the qualitative evaluation of strut coverage was found to be: kappa (κ)=0.91 (95% confidence interval (CI): 0.88-0.93, p<0.01), κ=0.88 (95% CI: 0.85-0.91, p<0.01), and κ=0.73 (95% CI: 0.68-0.78, p<0.01), respectively. CONCLUSIONS: FD-OCT is a reproducible and reliable imaging tool for quantitative evaluation of stented coronary segments, and for qualitative assessment of strut coverage.