Circ J ; 79(3): 613-22, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25746546

RESUMO

BACKGROUND: We sought to identify the feasibility of speckle tracking echocardiography (STE) to predict cardiac resynchronization therapy (CRT) responders in a prospective multicenter study. METHODS AND RESULTS: Patients who were newly implanted with a CRT device were enrolled. Time (T) from QRS to maximum peak radial and circumferential strain (CS) in 6 segments on the left ventricular (LV) short-axis plane, and to the maximum peak of longitudinal strain in 18 segments on 3 apical LV planes was measured (Tmax). In segments with multiple peaks on the time-strain curves, time to the first peak (Tfirst) was also assessed. Difference in T between the earliest and latest segment and standard deviation (SD) of T in each strain component were assessed. CRT responders were defined as having LV end-systolic volume reduction >15% at 6 months after CRT. Clinical outcomes were assessed with a composite endpoint of death from cardiac causes or unplanned hospitalization for heart failure. Among 180 patients, 109 patients were identified as responders. Tfirst-SD of CS >116 ms was selected as the best independent predictor of CRT responders (P<0.001, hazard ratio=9.83, 95% confidence interval 3.78-25.6). In addition, Tfirst-SD of CS was associated with the clinical endpoints. CONCLUSIONS: This prospective multicenter study revealed the high feasibility of dyssynchrony assessment by STE, which may improve the ability to predict CRT responders.


Assuntos
Terapia de Ressincronização Cardíaca , Ecocardiografia , Monitorização Fisiológica , Idoso , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Circ J ; 75(1): 129-34, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21127381

RESUMO

BACKGROUND: Previous studies have demonstrated that intrathoracic impedance monitoring (IIM) is associated with fluid overload. However, it remains unclear whether this new technology can predict heart failure (HF) before deterioration. Whether fluid status based on IIM predicts HF in patients with left ventricular (LV) systolic dysfunction was investigated. METHODS AND RESULTS: A prospective clinical observational study of 123 patients implanted with IIM-capable cardiac devices was carried out. The primary endpoint was the positive predictive value (PPV) at 12 months. Secondary endpoints were a correlation between onset of HF and IIM, optimal threshold of fluid index and duration between the alert and HF. Complete follow-up clinical data were obtained from 111 patients. During the observational period, 168 alerts were confirmed from 68 patients. In patient-based analysis (alert-based analysis), PPV was 33.8% (33.9%). Sensitivity, specificity and false positive was 67.6% (83.8%), 49.4% (28.4%) and 50.6% (71.6%), respectively. Mean duration between the alert and HF event was 21.4 ± 6.1 days. On multivariate logistic analysis, maximum fluid index, LV ejection fraction and atrial fibrillation were independent predictors of HF events. The optimal cut-off value determined by receiver operating characteristic curve was 114-ohm·day with sensitivity and specificity of 89.5% and 73.0%, respectively. CONCLUSIONS: IIM-based fluid index in patients with HF due to LV systolic dysfunction was effective in predicting worsening HF.


Assuntos
Cardiografia de Impedância , Insuficiência Cardíaca Sistólica/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico , Desequilíbrio Hidroeletrolítico/diagnóstico , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Terapia de Ressincronização Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Distribuição de Qui-Quadrado , Alarmes Clínicos , Desfibriladores Implantáveis , Impedância Elétrica , Desenho de Equipamento , Feminino , Insuficiência Cardíaca Sistólica/etiologia , Insuficiência Cardíaca Sistólica/fisiopatologia , Insuficiência Cardíaca Sistólica/terapia , Humanos , Japão , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Desequilíbrio Hidroeletrolítico/etiologia , Desequilíbrio Hidroeletrolítico/fisiopatologia