Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 28(4): 1334-1346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-31388967

RESUMO

BACKGROUND: Patient motion during pharmacological stressing can have substantial impact on myocardial blood flow (MBF) estimated from dynamic PET. This work evaluated a motion correction algorithm with and without adjustment of the PET attenuation map. METHODS: Frame-by-frame motion correction was performed by three users on 30 rubidium-82 studies. Data were divided equally into three groups of motion severity [mild (M1), moderate (M2) and severe (M3)]. MBF data were compared for non-motion corrected (NC), motion-corrected-only (MC) and with adjustment of the attenuation map (MCAC). Percentage differences of MBF were calculated in the coronary territories and 17-segment polar plots. Polar plots of spill-over were also generated from the data. RESULTS: Median differences of 23% were seen in the RCA and 18% for the LAD in the M3 category for MC vs NC images. Differences for MCAC vs MC images were considerably smaller and typically < 10%. Spill-over plots for MC and MCAC were notably more uniform compared with NC images. CONCLUSION: Motion correction for dynamic rubidium data is desirable for future MBF software updates. Adjustment of the PET attenuation map results in only marginal differences and therefore is unlikely to be an essential requirement. Assessing the uniformity of spill-over plots is a useful visual aid for verifying motion correction techniques.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Doença da Artéria Coronariana/fisiopatologia , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Radioisótopos de Rubídio
2.
Nucl Med Commun ; 36(7): 728-37, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25757197

RESUMO

OBJECTIVES: The last decade has seen considerable technological innovations in PET detectors with the availability, among other advances, of time-of-flight (TOF). TOF has been shown to increase the signal-to-noise ratio (SNR), which should allow for a reduction in acquired counts while maintaining image quality. METHODS: Fifty-eight patients referred for routine F-flurodeoxyglucose ((18)F-FDG) oncology PET studies were included in this study. Patients with weight below or above 100 kg were prescribed 350 or 400 MBq of (18)F-FDG, respectively. Listmode data were acquired for 2.5 min per bed position and reconstructed with ordered-subset expectation maximization (OSEM) reconstruction. TOF reconstruction was performed on reduced-count data, with two levels of reduction (-20 and -40% for patients <100 kg and -16 and -30% for patients >100 kg) achieved by clipping the listmode data. Liver SNR, mediastinum mean standardized uptake value (SUV(mean)), and lesion maximum standardized uptake value (SUV(max)) were measured in all images. All images were visually assessed as adequate or suboptimal. RESULTS: No significant difference was seen in mediastinum SUV(mean) or lesion SUV(max) when comparing reduced-count TOF with full-count OSEM images. Compared with the original OSEM images, liver SNR was higher for TOF images using the more conservative -20% reduction of counts (P < 0.001, Wilcoxon's signed-rank test), whereas no significant statistical difference was seen with -40% reductions. CONCLUSION: Incorporation of TOF allows for a reduction in acquired counts; this method has been implemented at our institution, with administered activity reduced for all patients to 280 MBq and a reduction in scan times for all but the largest patients. This has significantly reduced the patient radiation dose and improved scanner flexibility and throughput.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18 , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Razão Sinal-Ruído , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA