Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Health Technol Assess ; 26(50): 1-86, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36541393

RESUMO

BACKGROUND: The National Institute for Health and Care Excellence recommends macular laser to treat diabetic macular oedema with a central retinal subfield thickness of < 400 µm on optical coherence tomography. The DIAMONDS (DIAbetic Macular Oedema aNd Diode Subthreshold micropulse laser) trial compared standard threshold macular laser with subthreshold micropulse laser to treat diabetic macular oedema suitable for macular laser. OBJECTIVES: Determining the clinical effectiveness, safety and cost-effectiveness of subthreshold micropulse laser compared with standard threshold macular laser to treat diabetic macular oedema with a central retinal subfield thickness of < 400 µm. DESIGN: A pragmatic, multicentre, allocation-concealed, double-masked, randomised, non-inferiority, clinical trial. SETTING: Hospital eye services in the UK. PARTICIPANTS: Adults with diabetes and centre-involving diabetic macular oedema with a central retinal subfield thickness of < 400 µm, and a visual acuity of > 24 Early Treatment Diabetic Retinopathy Study letters (Snellen equivalent > 20/320) in one/both eyes. INTERVENTIONS: Participants were randomised 1 : 1 to receive 577 nm subthreshold micropulse laser or standard threshold macular laser (e.g. argon laser, frequency-doubled neodymium-doped yttrium aluminium garnet 532 nm laser); laser treatments could be repeated as needed. Rescue therapy with intravitreal anti-vascular endothelial growth factor therapies or steroids was allowed if a loss of ≥ 10 Early Treatment Diabetic Retinopathy Study letters between visits occurred and/or central retinal subfield thickness increased to > 400 µm. MAIN OUTCOME MEASURES: The primary outcome was the mean change in best-corrected visual acuity in the study eye at 24 months (non-inferiority margin 5 Early Treatment Diabetic Retinopathy Study letters). Secondary outcomes included the mean change from baseline to 24 months in the following: binocular best-corrected visual acuity; central retinal subfield thickness; the mean deviation of the Humphrey 10-2 visual field in the study eye; the percentage of people meeting driving standards; and the EuroQol-5 Dimensions, five-level version, National Eye Institute Visual Function Questionnaire - 25 and Vision and Quality of Life Index scores. Other secondary outcomes were the cost per quality-adjusted life-years gained, adverse effects, number of laser treatments and additional rescue treatments. RESULTS: The DIAMONDS trial recruited fully (n = 266); 87% of participants in the subthreshold micropulse laser group and 86% of participants in the standard threshold macular laser group had primary outcome data. Groups were balanced regarding baseline characteristics. Mean best-corrected visual acuity change in the study eye from baseline to month 24 was -2.43 letters (standard deviation 8.20 letters) in the subthreshold micropulse laser group and -0.45 letters (standard deviation 6.72 letters) in the standard threshold macular laser group. Subthreshold micropulse laser was deemed to be not only non-inferior but also equivalent to standard threshold macular laser as the 95% confidence interval (-3.9 to -0.04 letters) lay wholly within both the upper and lower margins of the permitted maximum difference (5 Early Treatment Diabetic Retinopathy Study letters). There was no statistically significant difference between groups in any of the secondary outcomes investigated with the exception of the number of laser treatments performed, which was slightly higher in the subthreshold micropulse laser group (mean difference 0.48, 95% confidence interval 0.18 to 0.79; p = 0.002). Base-case analysis indicated no significant difference in the cost per quality-adjusted life-years between groups. FUTURE WORK: A trial in people with ≥ 400 µm diabetic macular oedema comparing anti-vascular endothelial growth factor therapy alone with anti-vascular endothelial growth factor therapy and macular laser applied at the time when central retinal subfield thickness has decreased to < 400 µm following anti-vascular endothelial growth factor injections would be of value because it could reduce the number of injections and, subsequently, costs and risks and inconvenience to patients. LIMITATIONS: The majority of participants enrolled had poorly controlled diabetes. CONCLUSIONS: Subthreshold micropulse laser was equivalent to standard threshold macular laser but required a slightly higher number of laser treatments. TRIAL REGISTRATION: This trial is registered as EudraCT 2015-001940-12, ISRCTN17742985 and NCT03690050. FUNDING: This project was funded by the National Institute for Health and Care Research ( NIHR ) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 26, No. 50. See the NIHR Journals Library website for further project information.


The retina is a layer at the back of the eye. Its centre is called the macula and is responsible for central vision. Some people with diabetes develop diabetic macular oedema. In diabetic macular oedema fluid leaks from retinal blood vessels and builds up at the macula, resulting in sight loss. Diabetic macular oedema can be mild or severe; this can be determined measuring the thickness of the macula, which is measured in micrometres (µm). One micrometre is one thousandth of a millimetre. In mild diabetic macular oedema, the thickness of the macula increases, but is less than 400 µm. Patients with mild diabetic macular oedema can be treated with a laser and there are two laser types. The standard threshold macular laser has been available for many years. It clears the diabetic macular oedema but produces a 'burn' in the retina. The subthreshold micropulse laser is newer. It does not produce a burn but also clears the diabetic macular oedema. The lack of a burn, however, has led to doubts about whether or not this laser works as well as the standard threshold macular laser because 'no burn' was taken to mean 'less benefit'. These doubts led to our establishing the DIAMONDS (DIAbetic Macular Oedema aNd Diode Subthreshold micropulse laser) trial, which compared these two lasers for people with mild diabetic macular oedema. A total of 266 people suitable for either laser joined the study at 16 NHS hospitals across the UK; 133 received standard threshold macular laser and 133 received subthreshold micropulse laser. The choice of laser was determined by chance. The DIAMONDS trial found that the subthreshold micropulse laser was as good as the standard threshold macular laser (i.e. 'clinically equivalent') in terms of improving people's vision, reducing macula thickness, allowing people to meet driving standards and maintaining their quality of life, both in general terms and for vision in particular. There was a small increase (less than one session on average per person) in the number of laser treatment sessions needed with subthreshold micropulse laser. The costs of both laser treatments were about the same.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Edema Macular , Humanos , Adulto , Edema Macular/cirurgia , Retinopatia Diabética/cirurgia , Ranibizumab/efeitos adversos , Bevacizumab/efeitos adversos , Qualidade de Vida , Fatores de Crescimento Endotelial/uso terapêutico , Fotocoagulação a Laser/efeitos adversos , Fotocoagulação a Laser/métodos , Lasers
2.
Trials ; 20(1): 122, 2019 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-30755274

RESUMO

BACKGROUND: In the UK, macular laser is the treatment of choice for people with diabetic macular oedema with central retinal subfield thickness (CST) < 400 µm, as per National Institute for Health and Care Excellence guidelines. It remains unclear whether subthreshold micropulse laser is superior and should replace standard threshold laser for the treatment of eligible patients. METHODS: DIAMONDS is a pragmatic, multicentre, allocation-concealed, randomised, equivalence, double-masked clinical trial that aims to determine the clinical effectiveness and cost-effectiveness of subthreshold micropulse laser compared with standard threshold laser, for the treatment of diabetic macular oedema with CST < 400 µm. The primary outcome is the mean change in best-corrected visual acuity in the study eye from baseline to month 24 post treatment. Secondary outcomes (at 24 months) include change in binocular best corrected visual acuity; CST; mean deviation of the Humphrey 10-2 visual field; change in percentage of people meeting driving standards; European Quality of Life-5 Dimensions, National Eye Institute Visual Functioning Questionnaire-25 and VisQoL scores; incremental cost per quality-adjusted life year gained; side effects; number of laser treatments and use of additional therapies. The primary statistical analysis will be per protocol rather than intention-to-treat analysis because the latter increases type I error in non-inferiority or equivalence trials. The difference between lasers for change in best-corrected visual acuity (using 95% CI) will be compared to the permitted maximum difference of five Early Treatment Diabetic Retinopathy Study (ETDRS) letters. Linear and logistic regression models will be used to compare outcomes between treatment groups. A Markov-model-based cost-utility analysis will extend beyond the trial period to estimate longer-term cost-effectiveness. DISCUSSION: This trial will determine the clinical effectiveness and cost-effectiveness of subthreshold micropulse laser, when compared with standard threshold laser, for the treatment of diabetic macular oedema, the main cause of sight loss in people with diabetes mellitus. TRIAL REGISTRATION: International Standard Randomised Controlled Trials, ISRCTN17742985 . Registered on 19 May 2017 (retrospectively registered).


Assuntos
Retinopatia Diabética/cirurgia , Fotocoagulação a Laser/métodos , Edema Macular/cirurgia , Ensaios Clínicos Pragmáticos como Assunto , Análise Custo-Benefício , Interpretação Estatística de Dados , Método Duplo-Cego , Humanos , Modelos Logísticos , Avaliação de Resultados em Cuidados de Saúde , Tamanho da Amostra , Acuidade Visual
3.
Ophthalmology ; 122(7): 1348-55, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25892016

RESUMO

PURPOSE: To evaluate the efficacy and safety of intravitreal bevacizumab (Avastin; Genentech, South San Francisco, CA) in patients with neovascular age-related macular degeneration (nAMD) using 2 different treatment regimens in which patients were assessed clinically at up to 12-week intervals. DESIGN: Randomized, controlled, noninferiority trial. PARTICIPANTS: A total of 331 patients with nAMD. METHODS: Patients were treated with 1.25 mg intravitreal bevacizumab and followed up to 92 weeks. They were randomized into 2 arms. All patients received 3 loading doses 4 weeks apart and thereafter were assessed every 12 weeks until the end of the study. One arm received a routine treatment at each 12-week assessment, and the other arm was treated at these assessments on an as-needed basis. After the loading doses, patients in either arm who showed signs of disease activity had an additional assessment after 6 weeks and at that visit had top-up treatments on an as-needed basis. MAIN OUTCOME MEASURES: Mean best-corrected visual acuity (BCVA) at 92 weeks. RESULTS: At 92 weeks, patients who had treatments every 12 weeks had superior BCVA to those treated on an as-needed basis every 12 weeks (P = 0.008), with the regular treatment arm gaining a mean BCVA of 5.5 letters and the as-needed treatment arm gaining 0.6 letters. The regular treatment arm of the study showed significantly improved outcomes with respect to 5-, 10-, and 15-letter changes in BCVA from baseline compared with the as-needed treatment arm, as well as superior reading speed. In patients who completed the study, up to but not including week 92, the mean number of treatments was 10.8 for the regular treatment arm and 9.1 for the as-needed treatment arm. CONCLUSIONS: A treatment regimen with regular bevacizumab injections every 12 weeks after loading doses supplemented with as-needed top-up treatments produced a stable improvement in BCVA from baseline. The improvement in BCVA was broadly similar to that obtained in other studies using anti-vascular endothelial growth factor drugs with more frequent assessments and treatments.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Anticorpos Monoclonais Humanizados/administração & dosagem , Degeneração Macular Exsudativa/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/efeitos adversos , Anticorpos Monoclonais Humanizados/efeitos adversos , Bevacizumab , Feminino , Angiofluoresceinografia , Seguimentos , Humanos , Injeções Intravítreas , Masculino , Tomografia de Coerência Óptica , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual/fisiologia , Degeneração Macular Exsudativa/diagnóstico , Degeneração Macular Exsudativa/fisiopatologia
4.
PLoS One ; 9(4): e95074, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24759774

RESUMO

Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.


Assuntos
Computadores de Mão , Testes Visuais/instrumentação , Humanos , Interface Usuário-Computador
5.
J R Soc Interface ; 10(84): 20130239, 2013 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-23658115

RESUMO

There are a multitude of applications using modern tablet computers for vision testing that are accessible to ophthalmology patients. While these may be of potential future benefit, they are often unsupported by scientific assessment. This report investigates the pertinent physical characteristics behind one of the most common highest specification tablet computers with regard to its capacity for vision testing. We demonstrate through plotting of a gamma curve that it is feasible to produce a precise programmable range of central luminance levels on the device, even with varying background luminance levels. It may not be possible to display very low levels of contrast, but carefully using the gamma curve information allows a reasonable range of contrast sensitivity to be tested. When the screen is first powered on, it may require up to 15 min for the luminance values to stabilize. Finally, luminance of objects varies towards the edge of the screen and when viewed at an angle. However, the resulting effective contrast of objects is less variable. Details of our assessments are important to developers, users and prescribers of tablet clinical vision tests. Without awareness of such findings, these tests may never reach satisfactory levels of clinical validity and reliability.


Assuntos
Computadores de Mão/tendências , Sensibilidades de Contraste/fisiologia , Testes Visuais/instrumentação , Humanos , Interface Usuário-Computador , Acuidade Visual
7.
BMC Ophthalmol ; 4: 13, 2004 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-15387889

RESUMO

BACKGROUND: This paper attempts to clarify the usefulness of various simple pre-operative measures in estimating the potential for a visually successful capsulotomy. METHODS: 24 patients attending for capsulotomy had pre-operative measures of glare with BAT tester, visibility of posterior pole and grading of posterior capsular pearls and fibrosis seen at slit lamp. Visual function was measured before and after standardised capsulotomy. Correlations of the various preoperative measures with eventual visual function improvements were calculated. RESULTS: Pearls at slit lamp and poor posterior pole visualisation were all correlated with improvements in visual acuity and contrast sensitivity after capsulotomy. Amount of fibrosis visible at slit lamp and glare assessment were not correlated with vision improvements after laser. CONCLUSION: Of the various measures that are taken prior to Nd : YAG capsulotomy, some correlate with eventual visual improvement but for others no clinical utility was found. Practitioners should note these findings as they are especially of use in more questionable or high-risk cases to help determine whether referral for PCO treatment by Nd: YAG capsulotomy is likely to benefit the patient.


Assuntos
Catarata/diagnóstico , Técnicas de Diagnóstico Oftalmológico , Terapia a Laser , Cápsula do Cristalino/patologia , Complicações Pós-Operatórias/diagnóstico , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata , Feminino , Ofuscação , Humanos , Cápsula do Cristalino/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Cuidados Pré-Operatórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA