1.
Ultrasound Med Biol ; 50(4): 474-483, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38195266

RESUMO

OBJECTIVE: Despite recent improvements in medical imaging, the final diagnosis and biopathologic characterization of breast cancers currently still requires biopsies. Ultrasound is commonly used for clinical examination of breast masses. B-Mode and shear wave elastography (SWE) are already widely used to detect suspicious masses and differentiate benign lesions from cancers. But additional ultrasound modalities such as backscatter tensor imaging (BTI) could provide relevant biomarkers related to tissue organization. Here we describe a 3-D multiparametric ultrasound approach applied to breast carcinomas in the aims of (i) validating the ability of BTI to reveal the underlying organization of collagen fibers and (ii) assessing the complementarity of SWE and BTI to reveal biopathologic features of diagnostic interest. METHODS: Three-dimensional SWE and BTI were performed ex vivo on 64 human breast carcinoma samples using a linear ultrasound probe moved by a set of motors. Here we describe a 3-D multiparametric representation of the breast masses and quantitative measurements combining B-mode, SWE and BTI. RESULTS: Our results reveal for the first time that BTI can capture the orientation of the collagen fibers around tumors. BTI was found to be a relevant marker for assessing cancer stages, revealing a more tangent tissue orientation for in situ carcinomas than for invasive cancers. In invasive cases, the combination of BTI and SWE parameters allowed for classification of invasive tumors with respect to their grade with an accuracy of 95.7%. CONCLUSION: Our results highlight the potential of 3-D multiparametric ultrasound imaging for biopathologic characterization of breast tumors.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Abordagem GRADE , Mama/diagnóstico por imagem , Mama/patologia , Colágeno , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Diagnóstico Diferencial
2.
Ultrasound Med Biol ; 49(1): 269-277, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36441031

RESUMO

High-intensity focused ultrasound (HIFU) transducer acoustic output can vary over time as a result of an inconsistent power supply, damage to the transducer or deterioration over time. Therefore, easy implementation of a daily quality assurance (DQA) method is of great importance for pre-clinical research and clinical applications. We present here a thermochromic material-based phantom validated by thermal simulations and found to provide repeatable visual power output assessments in fewer than 15 s that are accurate to within 10%. Whereas current available methods such as radiation force balance measurements provide an estimate of the total acoustic power, we explain here that the thermochromic phantom is sensitive to the shape of the acoustic field at focus by changing the aperture of a multi-element transducer with a fixed acoustic power. The proposed phantom allows the end user to visually assess the transducer's functionality without resorting to expensive, time-consuming hydrophone measurements or image analysis.


Assuntos
Terapia por Ultrassom , Imagens de Fantasmas , Transdutores , Acústica , Processamento de Imagem Assistida por Computador
3.
Ultrasound Med Biol ; 48(9): 1867-1878, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35752513

RESUMO

Tumor growth, similarly to several other pathologies, tends to change the structural orientation of soft tissue fibers, which can become relevant markers for diagnosis. Current diagnosis protocols may require a biopsy for histological analysis, which is an invasive, painful and stressful procedure with a minimum turnaround time of 2 d. Otherwise, diagnosis may involve the use of complex methods with limited availability such as diffusion tensor imaging (magnetic resonance diffusion tensor imaging), which is not widely used in medical practice. Conversely, advanced methodologies in ultrasound imaging such as backscatter tensor imaging (BTI) might become a routine procedure in clinical practice at a limited cost. This method evaluates the local organization of soft tissues based on the spatial coherence of their backscattered ultrasonic echoes. Previous work has proven that BTI applied with matrix probes enables measurement of the orientation of soft tissue fibers, especially in the myocardium. The aims of the study described here were (i) to present for the first time a methodology for performing BTI in a volume on ex vivo human breast tumors using a linear probe and (ii) to display a first proof of concept of the link between BTI measurements and the orientation of collagen fibers.


Assuntos
Neoplasias da Mama , Imagem de Tensor de Difusão , Anisotropia , Neoplasias da Mama/diagnóstico por imagem , Colágeno , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Miocárdio
4.
Int J Hyperthermia ; 37(1): 231-244, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32133898

RESUMO

Purpose: Varicose veins are a common pathology that can be treated by endovenous thermal procedures like radiofrequency ablation (RFA). Such catheter-based techniques consist in raising the temperature of the vein wall to 70 to 120 °C to induce vein wall coagulation. Although effective, this treatment option is not suited for all types of veins and can be technically challenging.Materials and methods: In this study, we used High-Intensity Focused Ultrasound (HIFU) as a non-invasive thermal ablation procedure to treat varicose veins and we assessed the long-term efficacy and safety of the procedure in a sheep model. In vivo experiments were first conducted on two saphenous veins to measure the temperature rise induced at the vein wall during HIFU ablation and were compared with reported RFA-induced thermal rise. Thermocouples were inserted in situ to perform 20 measurements during 8-s ultrasound pulses at 3 MHz. Eighteen saphenous veins of nine anesthetized sheep (2-2.5 % Isoflurane) were then exposed to similar pulses (85 W acoustic, 8 s). After treatments, animals recovered from anesthesia and were followed up 30, 60 and 90 days post-treatment (n = 3 animals per group). At the end of the follow-up, vein segments and perivenous tissues were harvested and histologically examined.Results: Temperatures induced by HIFU pulses were found to be comparable to reported RFA treatments. Likewise, histological findings were similar to the ones reported after RFA and laser-based coagulation necrosis of the vein wall, thrombotic occlusions and vein wall fibrosis.Conclusion: These results support strongly the effectiveness and safety of HIFU for ablating non-invasively veins.


Assuntos
Ablação por Cateter/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Ultrassonografia/métodos , Varizes/diagnóstico por imagem , Varizes/terapia , Animais , Modelos Animais de Doenças , Feminino , Temperatura Alta , Ovinos
5.
J Appl Clin Med Phys ; 12(4): 3392, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22088999

RESUMO

The purpose of this study is to validate Eclipse's electron Monte Carlo algorithm (eMC) in heterogeneous phantoms using radiochromic films and EGSnrc as a reference Monte Carlo algorithm. Four heterogeneous phantoms are used in this study. Radiochromic films are inserted in these phantoms, including in heterogeneous media, and the measured relative dose distributions are compared to eMC calculations. Phantoms A, B, and C contain 1D heterogeneities, built with layers of lung- (phantom A) and bone- (phantoms B and C) equivalent materials sandwiched in Plastic Water. Phantom D is a thorax anthropomorphic phantom with 2D lung heterogeneities. Electron beams of 6, 9, 12 and 18 MeV from a Varian Clinac 2100 are delivered to these phantoms with a 10 × 10 cm2 applicator. Monte Carlo simulations with an independent algorithm (EGSnrc) are also used as a reference tool for two purposes: (1) as a second validation of the eMC dose calculations, and (2) to calculate the stopping power ratio between radiochromic films and bone medium, when dose is measured inside the heterogeneity. Percent depth dose (PDD) film measurements and eMC calculations agree within 2% or 3 mm for phantom A, and within 3% or 3 mm for phantoms B and C for almost all beam energies. One exception is observed with phantom B and the 6 MeV, where measured PDDs and those calculated with eMC differ by up to 4 mm. Gamma analysis of the measured and calculated 2D dose distributions in phantom D agree with criteria of 3%, 3mm for 9, 12, and 18 MeV beams, and criteria of 5%, 3 mm for the 6 MeV beam. Dose calculations in heterogeneous media with eMC agree within 3% or 3 mm with radiochromic film measurements. Six (6) MeV beams are not modeled as accurately as other beam energies. The eMC algorithm is suitable for clinical dose calculations involving lung and bone.


Assuntos
Algoritmos , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Osso e Ossos/diagnóstico por imagem , Elétrons , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Radiografia
SELEÇÃO DE REFERÊNCIAS