Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Orofac Orthop ; 81(3): 183-191, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32125437

RESUMO

PURPOSE: The aim of this study was to investigate the possible correlation between maxillary and mandibular positioning via cephalometric analysis with pterygomaxillary fissure (PMF) morphology using cone beam computed tomography (CBCT). METHODS: In this study, CBCT images from 825 individuals (448 female, 377 male; age range was 18-91 years with this cohort) were analyzed; PMF length and width were measured. Three-dimensional cephalometric analysis was also performed using cephalometric analysis software. The landmarks and measurements in relation to maxillary and mandibular positions were identified and performed for the cephalometric analysis. Analysis of variance (ANOVA) was used for comparison of the parameters, while the Bonferroni test was used for multiple comparisons. Pearson's test was also used to assess the correlations between the parameters. RESULTS: The results showed that males had significantly larger PMF length (p < 0.001) and width (p < 0.001) compared to females. The mean PMF length was 17.7 mm (standard deviation [SD] 3.2 mm) for right and 17.7 mm (SD 3.3 mm) for left but were not significantly different (p > 0.05). In terms of the cephalometric measurements, a significant correlation was found between upper central incisor (U1toAperp2D) and posterior facial height (PostFaceHtSGo2D) and PMF length, while correlations were found between PMF width and several cephalometric parameters such as lower lip (LwLiptoEPln2D and LwLiptoHLine2D) and occlusal plane (OPtoFHAng2D) (p < 0.05). CONCLUSION: A significant relationship was observed between PMF morphology and the position of the maxilla or mandible. PMF lengths and widths were larger in males than females. Posteroanterior maxillary and mandibular lengths and posterior facial height are associated with PMF length and width.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Maxila , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cefalometria , Feminino , Humanos , Incisivo , Masculino , Mandíbula , Pessoa de Meia-Idade , Adulto Jovem
2.
Folia Morphol (Warsz) ; 77(1): 79-89, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28653301

RESUMO

BACKGROUND: The aim of this investigation was to evaluate the length, thickness, sagittal and transverse angulations and the morphological variations of the stylohyoid complex (SHC), to assess their probable associations with age and gender, and to investigate the prevalence of it in a wide range of a Turkish sub-population by using cone beam computed tomography (CBCT). MATERIALS AND METHODS: The CBCT images of the 1000 patients were evaluated retrospectively. The length, thickness, sagittal and transverse angulations, morphological variations and ossification degrees of SHC were evaluated on multiplanar reconstructions (MPR) adnd three-dimensional (3D) volume rendering (3DVR) images. The data were analysed statistically by using nonparametric tests, Pearson's correlation coefficient, Student's t test, c2 test and one-way ANOVA. Statistical significance was considered at p < 0.05. RESULTS: It was determined that 684 (34.2%) of all 2000 SHCs were elongated (> 35 mm). The mean sagittal angle value was measured to be 72.24° and the mean transverse angle value was 70.81°. Scalariform shape, elongated type and nodular calcification pattern have the highest mean age values between the morphological groups, respectively. Calcified outline was the most prevalent calcification pattern in males. There was no correlation between length and the calcification pattern groups while scalariform shape and pseudoarticular type were the longest variations. CONCLUSIONS: We observed that as the anterior sagittal angle gets wider, SHC tends to get longer. The most observed morphological variations were linear shape, elongated type and calcified outline pattern. Detailed studies on the classification will contribute to the literature. (Folia Morphol 2018; 77, 1: 79-89).


Assuntos
Calcinose/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Ossificação Heterotópica/diagnóstico por imagem , Osso Temporal/anormalidades , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osso Temporal/diagnóstico por imagem , Turquia
3.
Dentomaxillofac Radiol ; 44(7): 20150070, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25900235

RESUMO

OBJECTIVES: This study assessed the influence of different voxel resolutions of two different CBCT units on the in vitro detection of periodontal defects. METHODS: The study used 12 dry skulls with a maxilla and a mandible. Artificial defects (dehiscence, tunnel, fenestration) were separately created on the anterior, premolar and molar teeth using burrs. A total of 14 dehiscences, 13 fenestrations, 8 tunnels and 16 non-defect controls were used in the study. Images were obtained from two different CBCT units in six voxel sizes (voxel size: 0.080, 0.100, 0.125, 0.150, 0.160 and 0.200 mm3). Kappa coefficients were calculated to assess both intra- and interobserver agreements for each image set. RESULTS: Overall intraobserver kappa coefficients ranged between 0.978 and 0.973 for the 0.080-mm3 images and between 0.751 and 0.737 for the 0.160-mm3 images, suggesting notably high intraobserver agreement for detecting periodontal defects. CBCT performed significantly better at detecting fenestrations (p<0.05) than tunnel and dehiscence defects. No statistically significant difference was found between the detection of dehiscence and tunnel defects (p>0.05). CONCLUSIONS: A voxel size of 0.150 mm3 was identified as the cut-off point for overall detection of periodontal defects. CBCT should be considered the most reliable imaging modality for the diagnosis of periodontal defects.


Assuntos
Perda do Osso Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Doenças Periodontais/diagnóstico por imagem , Processo Alveolar/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Técnicas In Vitro , Crânio/diagnóstico por imagem
4.
Dentomaxillofac Radiol ; 43(4): 20130332, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24645965

RESUMO

OBJECTIVES: To investigate the reliability and accuracy of cone beam CT (CBCT) images obtained at different fields of view in detecting and quantifying simulated buccal marginal alveolar peri-implant defects. METHODS: Simulated buccal defects were prepared in 69 implants inserted into cadaver mandibles. CBCT images at three different fields of view were acquired: 40 × 40, 60 × 60 and 100 × 100 mm. The presence or absence of defects was assessed on three sets of images using a five-point scale by three observers. Observers also measured the depth, width and volume of defects on CBCT images, which were compared with physical measurements. The kappa value was calculated to assess intra- and interobserver agreement. Six-way repeated analysis of variance was used to evaluate treatment effects on the diagnosis. Pairwise comparisons of median true-positive and true-negative rates were calculated by the χ² test. Pearson's correlation coefficient was used to determine the relationship between measurements. Significance level was set as p < 0.05. RESULTS: All observers had excellent intra-observer agreement. Defect status (p < 0.001) and defect size (p < 0.001) factors were statistically significant. Pairwise interactions were found between defect status and defect size (p = 0.001). No differences between median true-positive or true-negative values were found between CBCT field of views (p > 0.05). Significant correlations were found between physical and CBCT measurements (p < 0.001). CONCLUSIONS: All CBCT images performed similarly for the detection of simulated buccal marginal alveolar peri-implant defects. Depth, width and volume measurements of the defects from various CBCT images correlated highly with physical measurements.


Assuntos
Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/normas , Implantes Dentários , Doenças Mandibulares/diagnóstico por imagem , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/patologia , Processo Alveolar/patologia , Cadáver , Humanos , Processamento de Imagem Assistida por Computador/métodos , Doenças Mandibulares/patologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA