Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J AOAC Int ; 100(5): 1288-1293, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28797319

RESUMO

The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.


Assuntos
Análise Química do Sangue/normas , Ensaio de Proficiência Laboratorial , Vitamina D/análogos & derivados , Humanos , Controle de Qualidade , Padrões de Referência , Estados Unidos , Vitamina D/sangue
2.
J AOAC Int ; 100(5): 1244-1252, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28822355

RESUMO

The Vitamin D Standardization Program (VDSP) coordinated an interlaboratory study to assess the comparability of measurements of total 25-hydroxyvitamin D [25(OH)D] in human serum, which is the primary marker of vitamin D status. A set of 50 individual donor samples were analyzed by 15 different laboratories representing national nutrition surveys, assay manufacturers, and clinical and/or research laboratories to provide results for total 25(OH)D using both immunoassays (IAs) and LC tandem MS (MS/MS). The results were evaluated relative to bias compared with the target values assigned based on a combination of measurements at Ghent University (Belgium) and the U.S. National Institute of Standards and Technology using reference measurement procedures for the determination of 25(OH)D2 and 25(OH)D3. CV and mean bias for each laboratory and assay platform were assessed and compared with previously established VDSP performance criteria, namely CV ≤ 10% and mean bias ≤ 5%. Nearly all LC-MS/MS results achieved VDSP criteria, whereas only 50% of IAs met the criterion for a ≤10% CV and only three of eight IAs achieved the ≤5% bias. These results establish a benchmark for the evaluation of 25(OH)D assay performance and standardization activities in the future.


Assuntos
Análise Química do Sangue/normas , Vitamina D/análogos & derivados , Cromatografia Líquida/normas , Humanos , Imunoensaio/normas , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Vitamina D/sangue
3.
Clin Chem ; 61(8): 1107-13, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26071490

RESUMO

BACKGROUND: We used a difference in bias approach to evaluate the commutability of 4 frozen serum pools for 8 direct methods for measurement of HDL and LDL cholesterol (HDLC and LDLC). METHODS: Freshly collected nonfrozen sera from 138 diseased and 37 nondiseased patients and 4 frozen pools from the CDC Lipid Standardization Program were measured by direct methods and by the beta-quantification reference measurement procedure of the CDC. We used an error components model to estimate the difference in the bias component of error plus its uncertainty for frozen pools vs patient samples between the direct method and the reference procedure. Frozen pools with bias differences less than a critical value determined by either medical requirements for bias or the random error components of the measurement procedures were considered commutable. RESULTS: On the basis of medical requirement criteria, 1 of the 4 frozen pools was commutable for most of the HDLC methods for both diseased and nondiseased patients, and none was commutable for LDLC methods. On the basis of random error criteria, all of the frozen pools were generally commutable for all of the HDLC methods for both diseased and nondiseased patients, and 1 of the 4 frozen pools was generally commutable for most of the LDLC methods for both diseased and nondiseased patients. CONCLUSIONS: Commutability was assessed as the closeness of agreement of the difference in bias between a reference material and a set of patient samples. Criteria for commutability could be based on fixed medical requirements for bias or on random error components.


Assuntos
Análise Química do Sangue/métodos , Análise Química do Sangue/normas , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Humanos , Padrões de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA