RESUMO
BACKGROUND: The assessment of carotid intima-media thickness (CIMT) may improve cardiovascular risk prediction. The optimal protocol for CIMT measurement is unclear. CIMT may be measured in the common carotid artery (CCA), carotid bifurcation (CB), and internal carotid artery (ICA), but measurements from CB and ICA are more difficult to obtain. We studied the influence of body mass index (BMI) and atheroma plaques on the capacity to obtain CIMT measurements at different carotid sites. METHODS: Using an automatic system, CIMT was measured in 700 subjects aged 45-75, in the near and far walls of CCA, CB, and ICA bilaterally. The presence of atheroma plaques, BMI and vascular risk factors were recorded. RESULTS: CIMT measurements in CCA were possible in all except one subject. It was not possible to obtain CIMT measurements at CB or ICA in 24.1% of normal weight and 58.8% of obese subjects. The likelihood of obtaining CIMT measurement at all carotid sites decreased as the BMI increased. Atheroma plaques in a carotid segment did not preclude CIMT measurement at this site. CONCLUSIONS: CIMT measurements in distal carotid segments are more challenging in obese subjects. Measuring CIMT at CCA remains feasible in obese subjects and should be the primary endpoint in these subjects. Nevertheless, CB and ICA measurements, when feasible, would improve risk classification.
Assuntos
Índice de Massa Corporal , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/etiologia , Espessura Intima-Media Carotídea , Obesidade/complicações , Ultrassonografia Doppler Dupla/métodos , Fatores Etários , Idoso , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/prevenção & controle , Artérias Carótidas/patologia , Doenças das Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/patologia , Artéria Carótida Externa/diagnóstico por imagem , Artéria Carótida Externa/patologia , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/patologia , Estudos de Coortes , Intervalos de Confiança , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico , Obesidade/diagnóstico por imagem , Medição de Risco , Fatores Sexuais , Estatísticas não ParamétricasRESUMO
OBJECTIVE: We investigated whether regression of left ventricular hypertrophy (LVH) in response to antihypertensive treatment is associated with plasma cardiotrophin-1 (CT-1) in hypertensive patients. METHODS: The study was performed in 47 patients with mild to moderate essential hypertension, and LVH was assessed echocardiographically. The family doctor gave antihypertensive treatment and followed all patients. LVH regression was diagnosed if the baseline left ventricular mass index (LVMI) decreased to normal values after 1 year of treatment. Plasma CT-1 was determined by an enzyme-linked immunosorbent assay. RESULTS: The LVMI was normalized in 23 patients (49%) and persisted at an abnormally increased level in 24 patients (51%) after 1 year of treatment, whereas the reduction in clinic and home blood pressure was similar in the two groups: CT-1 decreased (-48%, P < 0.005) and increased (+35%, P < 0.05) in patients in whom LVH regressed and LVH persisted, respectively. Final values of CT-1 were inversely correlated (r = 0.534, P < 0.001) with the decrease in LVMI after treatment in all patients. A significant association (chi2 = 16.87, P < 0.001) was found between normalization of CT-1 and regression of LVH with treatment. A cut-off value of 41 fmol/ml for CT-1 provided a relative risk of 43.13 (95% confidence interval, 4.88-380.48) for detecting LVH regression. CONCLUSION: These results show an association between treatment-induced decrease of plasma CT-1 and LVH regression in essential hypertension. Although preliminary, these findings suggest that the determination of plasma CT-1 may be useful for the follow-up of hypertensive heart disease in routine clinical practice.