Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Am Heart J ; 149(5): 894-901, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15894974

RESUMO

OBJECTIVES: The aim of the study was to compare head-to-head the performance of exercise tolerance test-stress echocardiography (ex-Echo) and exercise stress-perfusion nuclear imaging (exercise-single-photon emission computed tomography [ex-SPECT]) for the diagnosis of coronary artery disease (CAD) in patients evaluated at the chest pain unit with delay from chest pain (CP) onset. BACKGROUND: As an early triage strategy for CAD in emergency medicine, ex-Echo could have the advantage of widespread availability and low costs. METHODS: In the years 2000-2002, 503 consecutive patients (mean age 60 years) with recent (<24 hours) CP and nonischemic electrocardiogram (ECG), in whom CAD remained undiagnosed after first line 6-hour work-up including serum markers of myocardial injury and resting echocardiogram, underwent ex-Echo and ex-SPECT within 24 hours. Patients with (+)ex-Echo or (+)ex-SPECT or (+)ex-ECG or abnormal troponin I were referred to coronary angiography; otherwise, they were discharged and followed up. End points were coronary stenosis > or =50% and cardiovascular events at 6-month follow-up. RESULTS: Ninety-nine patients (20%) had (+)ex-Echo and 121 (24%) (+)ex-SPECT; CAD was diagnosed in 81% and 67%, respectively; positive tests were concordant in 69%. In negative ex-Echo and ex-SPECT, final evidence of CAD emerged in 14 and 13, respectively. Ex-Echo demonstrated higher accuracy than ex-SPECT (93% +/- 1% vs 89% +/- 1%), optimal specificity (95% +/- 5% vs 90% +/- 5%), and positive predictive value (81% +/- 4% vs 67% +/- 4%); moreover, in the case of (-)ex-ECG, observed effective likelihood ratio indicates a (+)synergy between ex-ECG and ex-Echo. CONCLUSIONS: Ex-Echo can be an effective diagnostic strategy in the early triage of CP patients, improving diagnosis in case of (-)ex-ECG and reducing unnecessary angiography number. Its drawback is represented by the 5% of missed diagnosis.


Assuntos
Dor no Peito/etiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia sob Estresse , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Biomarcadores/sangue , Doença da Artéria Coronariana/complicações , Ecocardiografia sob Estresse/métodos , Eletrocardiografia , Serviço Hospitalar de Emergência , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Tomografia Computadorizada de Emissão de Fóton Único
2.
Ital Heart J ; 3(5): 308-17, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12066563

RESUMO

BACKGROUND: Sudden cardiac death represents a major public health problem, but in the general population the identification of those subjects at very high risk remains poor. Simultaneous multiparametric ECG analysis can improve the identification of high-risk patients. METHODS: Five-min ECG recordings at a 5 MHz sampling rate (extended length-XL-ECG, Mortara Instruments, Milwaukee, WI, USA) were acquired in 105 healthy subjects (age range 21 to 80 years), equally distributed for age decades and sex, and three additional recordings, 30 min apart, were repeated in 30 subjects on the second day. The following parameters were recorded and analyzed: the RR interval, QRS duration, QT interval corrected according to the Bazett and Fridericia formulae, QT dispersion, T wave complexity, activation-recovery interval dispersion, standard deviation of the RR intervals, filtered QRS duration, the square root of the mean voltage of the last 40 ms of the filtered QRS, and the length of time that the terminal vector magnitude complex remains < 40 microV. RESULTS: QRS duration, activation-recovery interval dispersion, and filtered QRS differed in the two sexes. The standard deviation of the RR intervals, T wave complexity and QT dispersion were significantly correlated with age. The reproducibility was good for each parameter. CONCLUSIONS: The XL-ECG allows the simultaneous calculation of eight adequately reproducible different parameters the values of which are in agreement with those of the literature. Thus, XL-ECG is a reliable time- and cost-saving tool.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia Ambulatorial/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA