Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nutr Metab Cardiovasc Dis ; 32(3): 586-595, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35109998

RESUMO

BACKGROUND AND AIMS: The aim of the present study is to evaluate whether advanced coronary atherosclerosis analysis by CCTA may improve prognostic stratification among diabetic patients at high cardiovascular risk (CV risk). METHODS AND RESULTS: The study population consisted of 265 consecutive diabetic patients at high CV risk who underwent CCTA for suspected CAD between January 2011 and December 2016. For every patients both traditional and advanced, qualitative and quantitative coronary plaque analysis were performed. The occurrence of cardiac death, ACS, and non-urgent revascularization were recorded at follow-up. Among the 265 patients enrolled, 21 were lost to follow-up, whereas 244 (92%) had a complete follow-up (mean 45 ± 22 months) and were classified at high (n = 67) or very high cardiovascular risk (n = 177), according to ESC Guidelines. A total of 63 events were recorded (3 Cardiac Death, 3 NSTEMI, 8 unstable angina, 36 late non-urgent revascularization and 13 non-cardiac death) in 57 different patients. Elevated fibro-fatty plaque volume was the only predictor of events over age, gender and traditional risk factor when ACS and MACE were considered as end-points [HR (95% CI) 6.01 (1.65-21.87), p = 0.006 and 3.46 (2.00-5.97); p < 0.001]. CONCLUSION: The present study confirms the prognostic role of advance coronary atherosclerosis evaluation beyond risk factors and stenosis severity, even in diabetics. Despite the very high cardiovascular risk of study population, a not negligible portion (23%) of patients exhibited totally normal coronaries.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Placa Aterosclerótica , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/diagnóstico , Seguimentos , Humanos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/terapia , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco
2.
EuroIntervention ; 17(18): 1498-1505, 2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-34647890

RESUMO

BACKGROUND: Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is superior to angiography-guided PCI. The clinical uptake of FFR has been limited, however, by the need to advance a wire in the coronary artery, the additional time required and the need for hyperaemic agents which can cause patient discomfort. FFR derived from routine coronary angiography eliminates these issues. AIMS: The aim of this study was to assess the diagnostic performance and accuracy of three-dimensional quantitative coronary angiography (3D-QCA)-based vessel FFR (vFFR) compared to pressure wire-based FFR (≤0.80). METHODS: The FAST II (Fast Assessment of STenosis severity) study was a prospective observational multicentre study designed to evaluate the diagnostic accuracy of vFFR compared to the reference standard (pressure wire-based FFR ≤0.80). A total of 334 patients from six centres were enrolled. Both site-determined and blinded independent core lab vFFR measurements were compared to FFR. RESULTS: The core lab vFFR was 0.83±0.09 and pressure wire-based FFR 0.83±0.08. A good correlation was found between core lab vFFR and pressure wire-based FFR (R=0.74; p<0.001; mean bias 0.0029±0.0642). vFFR had an excellent diagnostic accuracy in identifying lesions with an invasive wire-based FFR ≤0.80 (area under the curve [AUC] 0.93; 95% confidence interval [CI]: 0.90-0.96; p<0.001). Positive predictive value, negative predictive value, diagnostic accuracy, sensitivity and specificity of vFFR were 90%, 90%, 90%, 81% and 95%, respectively. CONCLUSIONS: 3D-QCA-based vFFR has excellent diagnostic performance to detect FFR ≤0.80. The study was registered on clinicaltrials.gov under identifier NCT03791320.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Constrição Patológica , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença
3.
Cardiovasc Res ; 118(6): 1385-1412, 2022 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-34864874

RESUMO

AIMS: Since its emergence in early 2020, the novel severe acute respiratory syndrome coronavirus 2 causing coronavirus disease 2019 (COVID-19) has reached pandemic levels, and there have been repeated outbreaks across the globe. The aim of this two-part series is to provide practical knowledge and guidance to aid clinicians in the diagnosis and management of cardiovascular disease (CVD) in association with COVID-19. METHODS AND RESULTS: A narrative literature review of the available evidence has been performed, and the resulting information has been organized into two parts. The first, reported here, focuses on the epidemiology, pathophysiology, and diagnosis of cardiovascular (CV) conditions that may be manifest in patients with COVID-19. The second part, which will follow in a later edition of the journal, addresses the topics of care pathways, treatment, and follow-up of CV conditions in patients with COVID-19. CONCLUSION: This comprehensive review is not a formal guideline but rather a document that provides a summary of current knowledge and guidance to practicing clinicians managing patients with CVD and COVID-19. The recommendations are mainly the result of observations and personal experience from healthcare providers. Therefore, the information provided here may be subject to change with increasing knowledge, evidence from prospective studies, and changes in the pandemic. Likewise, the guidance provided in the document should not interfere with recommendations provided by local and national healthcare authorities.


Assuntos
COVID-19 , Cardiologia , Doenças Cardiovasculares , COVID-19/diagnóstico , COVID-19/epidemiologia , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Humanos , Pandemias , Estudos Prospectivos
4.
Front Cardiovasc Med ; 8: 730626, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34722664

RESUMO

Background and Purpose: The Active Connection Matrixes (ACMs) are unsupervised artificial adaptive systems able to extract from digital images features of interest (edges, tissue differentiation, etc.) unnoticeable with conventional systems. In this proof-of-concept study, we assessed the potentiality of ACMs to increase measurement precision of morphological structures (e.g., stenosis and lumen diameter) and to grasp morphological features (arterial walls) from quantitative coronary angiography (QCA), unnoticeable on the original images. Methods: Archive images of QCA and intravascular ultrasound (IVUS) of 10 patients (8 men, age 69.1 ± 9.7 years) who underwent both procedures for clinical reasons were retrospectively analyzed. Arterial features derived from "IVUS images," "conventional QCA images," and "ACM-reprocessed QCA images" were measured in 21 coronary segments. Portions of 1-mm length (263 for lumen and 526 for arterial walls) were head-to-head compared to assess quali-quantitative between-methods agreement. Results: When stenosis was calculated on "ACM-reprocessed QCA images," the bias vs. IVUS (gold standard) did not improve, but the correlation coefficient of the QCA-IVUS relationship increased from 0.47 to 0.83. When IVUS-derived lumen diameters were compared with diameters obtained on ACM-reprocessed QCA images, the bias (-0.25 mm) was significantly smaller (p < 0.01) than that observed with original QCA images (0.58 mm). ACMs were also able to extract arterial wall features from QCA. The bias between the measures of arterial walls obtained with IVUS and ACMs, although significant (p < 0.01), was small [0.09 mm, 95% CI (0.03, 0.14)] and the correlation was fairly good (r = 0.63; p < 0.0001). Conclusions: This study provides proof of concept that ACMs increase the measurement precision of coronary lumen diameter and allow extracting from QCA images hidden features that mirror well the arterial walls derived by IVUS.

5.
Can J Cardiol ; 36(6): 961-964, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32376346

RESUMO

Owing to the COVID-19 outbreak in Lombardy, Italy) there is an urgent need to manage cardiovascular emergencies, including acute coronary syndrome (ACS), with appropriate standards of care and dedicated preventive measures and pathways against the risk of SARS-CoV-2 infection. For this reason, the Government of Lombardy decided to centralize the treatment of ACS patients in a limited number of centers, including our university cardiology institute, which in the past 4 weeks became a cardiovascular emergency referral center in a regional hub-and-spoke system. Therefore, we rapidly developed a customized pathway to allocate patients to the appropriate hospital ward, and treat them according to ACS severity and risk of suspected SARS-CoV-2 infection. We present here the protocol dedicated to ACS patients adopted in our center since March 13, 2020, and our initial experience in the management of ACS patients during the first 4 weeks of its use. Certainly, the protocol has room for further improvement as everyone's experience grows, but we hope that it could be a starting point, adaptable to different realities and local resources.


Assuntos
Síndrome Coronariana Aguda , Infecções por Coronavirus , Procedimentos Clínicos , Serviço Hospitalar de Emergência , Controle de Infecções , Pandemias , Administração dos Cuidados ao Paciente , Pneumonia Viral , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/terapia , Idoso , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/terapia , Serviço Hospitalar de Emergência/organização & administração , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Itália/epidemiologia , Masculino , Inovação Organizacional , Pandemias/prevenção & controle , Administração dos Cuidados ao Paciente/métodos , Administração dos Cuidados ao Paciente/organização & administração , Pneumonia Viral/epidemiologia , Pneumonia Viral/terapia , Gestão de Riscos/métodos , SARS-CoV-2
6.
Circ Cardiovasc Imaging ; 9(10)2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27894070

RESUMO

BACKGROUND: Computed tomography coronary angiography (cTCA) and stress cardiac magnetic resonance (stress-CMR) are suitable tools for diagnosing obstructive coronary artery disease in symptomatic patients with previous history of revascularization. However, performance appraisal of noninvasive tests must take in account the consequent diagnostic testing, invasive procedures, clinical outcomes, radiation exposure, and cumulative costs rather than their diagnostic accuracy only. We aimed to compare an anatomic (cTCA) versus a functional (stress-CMR) strategy in symptomatic patients with previous myocardial revascularization procedures. METHODS AND RESULTS: Six hundred patients with chest pain and previous revascularization included in a prospective observational registry and evaluated by clinically indicated cTCA (n=300, mean age 68.2±9.7 years, male 255) or stress-CMR (n=300, mean age 67.6±9.7 years, male 263) were enrolled and followed-up in terms of subsequent noninvasive tests, invasive coronary angiography, revascularization procedures, cumulative effective radiation dose, major adverse cardiac events, defined as a composite end point of nonfatal myocardial infarction and cardiac death, and medical costs. The mean follow-up for cTCA and stress-CMR groups was similar (773.6±345 versus 752.8±291 days; P=0.21). Compared with stress-CMR, cTCA was associated with a higher rate of subsequent noninvasive tests (28% versus 17%; P=0.0009), invasive coronary angiography (31% versus 20%; P=0.0009), and revascularization procedures (24% versus 16%; P=0.007). Stress-CMR strategy was associated with a significant reduction of radiation exposure and cumulative costs (59% and 24%, respectively; P<0.001). Finally, patients undergoing stress-CMR showed a lower rate of major adverse cardiac events (5% versus 10%; P<0.010) and cost-effectiveness ratio (119.98±250.92 versus 218.12±298.45 Euro/y; P<0.001). CONCLUSIONS: Compared with cTCA, stress-CMR is more cost-effective in symptomatic revascularized patients.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Revascularização Miocárdica , Vasodilatadores/administração & dosagem , Idoso , Causas de Morte , Angiografia por Tomografia Computadorizada/economia , Angiografia Coronária/economia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/economia , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Análise Custo-Benefício , Feminino , Custos de Cuidados de Saúde , Humanos , Itália , Imageamento por Ressonância Magnética/economia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Revascularização Miocárdica/efeitos adversos , Revascularização Miocárdica/economia , Revascularização Miocárdica/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Sistema de Registros , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Vasodilatadores/economia
7.
Circ Cardiovasc Imaging ; 9(10)2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27729359

RESUMO

BACKGROUND: The aim of this study was to determine the prognostic benefit of cardiac magnetic resonance (CMR) over transthoracic echocardiography (TTE) in ischemic cardiomyopathy and nonischemic dilated cardiomyopathy patients evaluated for primary prevention implantable cardioverter-defibrillator therapy. METHODS AND RESULTS: We enrolled 409 consecutive ischemic and dilated cardiomyopathy patients (mean age: 64±12 years; 331 men). All patients underwent TTE and CMR, and left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricle ejection fraction (LVEF) were evaluated. In addition, late gadolinium enhancement was also assessed. All patients were followed up for major adverse cardiac events (MACE) defined as a composite end point of long runs of nonsustained ventricular tachycardia, sustained ventricular tachycardia, aborted sudden cardiac death, or sudden cardiac death. The median follow-up was 545 days. CMR showed higher left ventricle end-diastolic volume (mean difference: 43±22.5 mL), higher left ventricle end-systolic volume (mean difference: 34±20.5 mL), and lower LVEF (mean difference: -4.9±10%) as compared to TTE (P<0.01). MACE occurred in 103 (25%) patients. Patients experiencing MACE showed higher left ventricle end-diastolic volume, higher left ventricle end-systolic volume, and lower LVEF with both imaging modalities and higher late gadolinium enhancement per-patient prevalence as compared to patients without MACE. At multivariable analysis, CMR-LVEF ≤35% (hazard ratio=2.18 [1.3-3.8]) and the presence of late gadolinium enhancement (hazard ratio=2.2 [1.4-3.6]) were independently associated with MACE (P<0.01). A model based on CMR-LVEF ≤35% or CMR-LVEF ≤35% plus late gadolinium enhancement detection showed a higher performance in the prediction of MACE as compared to TTE-LVEF resulting in net reclassification improvement of 0.468 (95% confidence interval, 0.283-0.654; P<0.001) and 0.413 (95% confidence interval, 0.23-0.63; P<0.001), respectively. CONCLUSIONS: CMR provides additional prognostic stratification as compared to TTE, which may have direct impact on the indication of implantable cardioverter-defibrillator implantation.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis , Ecocardiografia/métodos , Cardioversão Elétrica/instrumentação , Imagem Cinética por Ressonância Magnética , Isquemia Miocárdica/complicações , Prevenção Primária/instrumentação , Encaminhamento e Consulta , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Cardiomiopatia Dilatada/etiologia , Cardiomiopatia Dilatada/fisiopatologia , Distribuição de Qui-Quadrado , Meios de Contraste/administração & dosagem , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Prevenção Primária/métodos , Modelos de Riscos Proporcionais , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda
8.
JACC Cardiovasc Interv ; 9(12): 1216-1227, 2016 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-27339838

RESUMO

OBJECTIVES: The study compared, by intravascular ultrasound (IVUS), acute gain (AG) at the site of the pre-procedural minimal lumen area (MLA) achieved by either the Absorb (Abbott Vascular, Santa Clara, California) scaffold or the Xience stent and identified the factors contributing to the acute performance of these devices. BACKGROUND: It is warranted that the acute performance of Absorb matches that of metallic stents; however, concern exists about acute expansion and lumen gain with the use of Absorb. METHODS: Of a total of 501 patients (546 lesions) in the ABSORB II (ABSORB II Randomized Controlled Trial) randomized trial, 445 patients with 480 lesions were investigated by IVUS pre- and post-procedure. Comparison of MLA pre- and post-procedure was performed at the MLA site by matching pre- and post-procedural IVUS pullbacks. RESULTS: Lower AG on IVUS (lowest tertile) occurred more frequently in the Absorb arm than in the Xience arm (3.46 mm(2) vs. 4.27 mm(2), respectively; p < 0.001; risk ratio: 3.04; 95% confidence interval: 1.94 to 4.76). The plaque morphology at the MLA cross-section was not independently associated with IVUS acute gain. The main difference in AG in MLD by angiography was observed at the time of device implantation (Xience vs. Absorb, Δ+1.50 mm vs. Δ+1.23 mm, respectively), whereas the gain from post-dilation was similar between the 2 arms (Δ+0.16 mm vs. Δ+0.16 mm) when patients underwent post-dilation, although expected balloon diameter was smaller in the Absorb arm than in the Xience arm (p = 0.003) during post-dilation. CONCLUSIONS: At the site of the pre-procedural MLA, the increase of the lumen post-procedure was smaller in the Absorb-arm than in the Xience arm. To achieve equivalent AG to Xience, the implantation of Absorb may require more aggressive strategies at implantation, pre- and post-dilation than the technique used in the ABSORB II trial. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença das Coronárias/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Metais , Stents , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Everolimo/efeitos adversos , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
Am J Cardiol ; 112(11): 1790-9, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24045059

RESUMO

The evaluation of the aortic root in patients referred for transcatheter aortic valve implantation is crucial. The aim of the present study was to compare the accuracy of cardiac magnetic resonance (CMR) evaluation of the aortic annulus (AoA) with transthoracic and transesophageal echocardiography and multidetector computed tomography (MDCT) in patients referred for transcatheter aortic valve implantation. In 50 patients, maximum diameter, minimum diameter and AoA, length of the left coronary, right coronary, and noncoronary aortic leaflets, degree (grades 1 to 4) of aortic leaflet calcification, and distance between AoA and coronary artery ostia were assessed. AoA maximum diameter, minimum diameter, and area by CMR were 26.4 ± 2.8 mm, 20.6 ± 2.3 mm, 449.8 ± 86.2 mm(2), respectively. The length of left coronary, right coronary, and noncoronary leaflets by CMR were 13.9 ± 2.2, 13.3 ± 2.1, and 13.4 ± 1.8 mm, respectively, whereas the score of aortic leaflet calcifications was 2.9 ± 0.8. Finally, the distances between AoA and left main and right coronary artery ostia were 16.1 ± 2.8 and 16.1 ± 4.4 mm, respectively. Regarding AoA area, transthoracic and transesophageal echocardiography showed an underestimation (p <0.01), with a moderate agreement (r: 0.5 and 0.6, respectively, p <0.01) compared with CMR. No differences and excellent correlation were observed between CMR and MDCT for all parameters (r: 0.9, p <0.01), except for aortic leaflet calcifications that were underestimated by CMR. In conclusion, aortic root assessment with CMR including AoA size, aortic leaflet length, and coronary artery ostia height is accurate compared with MDCT. CMR may be a valid imaging alternative in patients unsuitable for MDCT.


Assuntos
Aorta , Estenose da Valva Aórtica/diagnóstico , Valva Aórtica , Técnicas de Imagem Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Aorta/patologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Aortografia , Cateterismo Cardíaco , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia Computadorizada Multidetectores
10.
Int J Cardiol ; 167(6): 2889-94, 2013 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-22959395

RESUMO

BACKGROUND: The aims of this study are to evaluate the accuracy of low dose multidetector computed tomography coronary angiography (MDCT) versus invasive coronary angiography (ICA) in ruling out CAD in patients with mitral valve prolapse and severe mitral regurgitation (MVP) before cardiac surgery and to compare the overall effective radiation dose (ED) and cost of a diagnostic approach in which conventional ICA should be performed only in patients with significant CAD as detected by MDCT. METHODS: Eighty patients with MVP and without history of CAD were randomized to MDCT (Group 1) or ICA (Group 2) to rule out CAD before surgery. However, ICA was also performed as gold standard reference in Group 1 to test the diagnostic accuracy of MDCT. A diagnostic work-up A in whom all patients underwent low-dose MDCT as initial diagnostic test and those with positive findings were referred for ICA was compared with work-up B in which all patients were referred for ICA according to the standard of care in terms of ED and cost. RESULTS: The two groups were homogeneous in terms of gender, age and body mass index. The overall feasibility and accuracy in a patient-based model were 99% and 93%, respectively. The overall ED and costs were significantly lower in diagnostic work-up A compared to diagnostic work-up B. CONCLUSIONS: The accuracy of low dose MDCT for ruling out the presence of significant CAD in patients undergoing elective valve surgery for mitral valve prolapse is excellent with a reduction of overall radiation dose exposure and costs.


Assuntos
Angiografia Coronária/normas , Prolapso da Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/normas , Cuidados Pré-Operatórios/normas , Doses de Radiação , Encaminhamento e Consulta/normas , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/economia , Custos e Análise de Custo/economia , Custos e Análise de Custo/métodos , Feminino , Humanos , Masculino , Prolapso da Valva Mitral/economia , Prolapso da Valva Mitral/epidemiologia , Tomografia Computadorizada Multidetectores/economia , Cuidados Pré-Operatórios/economia , Encaminhamento e Consulta/economia
11.
Am Heart J ; 164(4): 576-84, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23067917

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a valid alternative to surgery in high-risk patients with severe aortic stenosis. Aortic annulus (AoA) sizing is crucial for TAVI success. The aim of the study was to compare AoA dimensions measured by multidetector computed tomography (MDCT) vs those obtained with transthoracic (TTE) and transesophageal echocardiography (TEE) for predicting paravalvular aortic regurgitation (PVR) after TAVI. METHODS: Aortic annulus maximum diameter, minimum diameter, and area were assessed using MDCT and compared with TTE and TEE diameter and area for predicting PVR after TAVI in 151 patients (45 men, age 81.2 ± 6.4 years). RESULTS: Aortic annulus maximum, minimum diameter, and area detected by MDCT were 25.04 ± 2.39 mm, 21.27 ± 2.10 mm, and 420.87 ± 76.10 mm(2), respectively. Aortic annulus diameter and area measured by TTE and TEE were 21.14 ± 1.94 mm and 353.82 ± 64.57 mm(2) and 22.04 ± 1.94 mm and 384.33 ± 67.30 mm(2), respectively. A good correlation was found between AoA diameters and area evaluated by MDCT vs TTE and TEE (0.61, 0.65, and 0.69 and 0.61, 0.65, and 0.70, respectively), with a mean difference of 3.90 ± 1.98 mm, 0.13 ± 1.67 mm, and 67.05 ± 55.87 mm(2) and 3.0 ± 2.0 mm, 0.77 ± 1.70 mm, and 36.54 ± 56.43 mm(2), respectively. Grade ≥2 PVR occurred in 46 patients and was related to male gender, higher body mass index, preprocedural aortic regurgitation, and lower mismatch between the nominal area of the implanted prosthesis and AoA area detected by MDCT. CONCLUSIONS: Mismatch between prosthesis area and AoA area detected by MDCT is a better predictor of PVR as compared with echocardiography mismatch. Specific MDCT-based sizing recommendations should be developed.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/patologia , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Tamanho do Órgão
12.
Radiology ; 265(2): 410-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22966068

RESUMO

PURPOSE: To compare accuracy and radiation exposure of a new computed tomographic (CT) scanner with improved spatial resolution (scanner A) with those of a CT scanner with standard spatial resolution (scanner B) for evaluation of coronary in-stent restenosis (ISR) by using invasive coronary angiography (ICA) and intravascular ultrasonography (US) as reference methods. MATERIALS AND METHODS: Written informed consent was obtained and study protocol was approved by institutional ethics committee. A total of 180 consecutive patients (154 men [mean age ± standard deviation, 66 years±12; range, 51-79 years] and 36 women [mean age, 70 years±12; range, 55-83 years]) scheduled to undergo ICA for suspected ISR were enrolled. Ninety patients were studied with scanner A (group 1: 72 men [mean age, 65 years±11; range, 52-79], 18 women [mean age, 68 years±12; range, 55-83 years]) and 90 with scanner B (group 2: 74 men [mean age, 64 years±10; range, 51-77 years], 16 women [mean age, 68 years±11; range, 55-82 years). Examination with the two scanners was compared with ICA and intravascular US. Radiation dose exposure was estimated. To compare stent evaluability between the two groups, χ2 test was used. RESULTS: Stent evaluability was higher in group 1 than in group 2 (99% vs 92%, P=.0021). A significantly lower rate of beam-hardening artifact was observed in group 1 (two cases) than group 2 (12 cases, P<.05). For stent-based analysis, sensitivity, specificity, and accuracy of multidetector CT for ISR identification were 96%, 95%, and 96% in group 1 and 90%, 91%, and 91% in group 2, respectively, without statistically significant differences. The correlation between percent ISR evaluated at multidetector CT versus intravascular US was higher in group 1 than in group 2 (r=0.89 vs r=0.58; P=.019). The correlations of diameter and area measurements at reference site and stent maximal lumen narrowing site between multidetector CT and intravascular US were higher in group 1 than in group 2. Radiation dose was low in both multidetector CT groups (1.9 mSv±0.2). CONCLUSION: Scanner A, with improved spatial resolution, allowed reliable detection and quantification of coronary ISR with low radiation exposure.


Assuntos
Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Intensificação de Imagem Radiográfica/métodos , Stents/efeitos adversos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
13.
Eur Radiol ; 21(7): 1430-8, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21331594

RESUMO

OBJECTIVES: The accuracy of computed tomography (CT) for assessment of coronary stents is as yet unproven and radiation exposure has been a concern. The aim of our study is to compare radiation dose and diagnostic performance of CT with prospective ECG-triggering versus retrospective ECG-triggering for the detection of in-stent restenosis (ISR). METHODS: We enrolled 168 consecutive patients with suspected ISR, 83 studied using CT with prospective ECG-triggering (group 1) and 85 using retrospective ECG-triggering (group 2). RESULTS: Prevalence of ISR according to catheter angiography was 24% in both groups. The overall evaluability was similar (93% in group 1 vs 95% in group 2). Artefact sub-analysis showed a significantly lower number of blooming and higher number of slice misalignment in group 1 vs group 2. In the stent-based analysis using only evaluable stents, specificity, positive predictive value and accuracy were significantly higher in group 1 (100%, 100% and 99%, respectively) than in group 2 (97%, 91% and 95%, respectively, p < 0.05). Group 1 was exposed to a lower radiation dose compared with group 2 (4.3 ± 1.4 mSv vs 18.5 ± 5.5 mSv, p < 00.1). CONCLUSIONS: CT with prospective ECG-triggering can improve diagnostic accuracy of non-invasive imaging of coronary stents with a significant reduction in radiation exposure.


Assuntos
Angiografia Coronária/métodos , Reestenose Coronária/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Stents , Tomografia Computadorizada por Raios X/métodos , Distribuição de Qui-Quadrado , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iopamidol/análogos & derivados , Modelos Lineares , Masculino , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
J Invasive Cardiol ; 15(1): 1-5, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12499519

RESUMO

Stenting without predilatation has become possible due to the availability of a new generation of flexible, low-profile, securely crimped, balloon-expandable stents. This study compared the feasibility, efficacy and cost-effectiveness of direct stenting (DS) to the standard predilatation technique (PS) using the premounted Crossflex LC stent (Cordis Corporation, Miami Lakes, Florida). The study is a randomized prospective multicenter evaluation including 271 patients (140 patients in the DS group and 131 patients in the PS group) with 1 or 2 de novo or restenotic lesions located in native coronary arteries. Procedural success was 98.9% and 98.7% in the DS and PS groups, respectively (p = NS); crossover to PS was required in 22/166 lesions (13.2%) enrolled in the DS group because of inability to cross the target lesion without predilatation. Nonsignificant reductions in procedural time (-10.5%), fluoroscopy time (-4.7%) and amount of contrast (-3.8%) were observed in the DS group in comparison to the PS group. The number of balloons used (-76.6%) and the global cost of the procedure (-18.8%) were significantly lower in the DS group (p < 0.01 for both comparisons). After 6 months, no differences were observed in the restenosis rate between the two groups (22.0% for DS group versus 18.1% for PS group; p = NS) and in the incidence of major adverse clinical events (5.0% for DS group versus 3.0% for PS group; p = NS). Direct stenting is safe and feasible for the treatment of lesions in native coronary arteries and obtains a significant reduction in procedural cost, mainly due to the lower number of balloons used. Clinical and angiographic results at 6 months are comparable to those obtained after a conventional predilatation-stenting strategy.


Assuntos
Doença da Artéria Coronariana/terapia , Stents , Cateterismo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Análise Custo-Benefício , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Segurança , Fatores de Tempo
15.
J Invasive Cardiol ; 14(8): 452-6, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12147875

RESUMO

Although most patients with coronary artery aneurysms are asymptomatic, manifestations of myocardial ischemia may occur. However, the role that a coronary aneurysm may play in impairing arterial flow of an otherwise normal coronary circulation is not completely known. A 64-year-old woman with previous anteroseptal myocardial infarction was found to have a large aneurysm of the proximal left anterior descending (LAD) coronary artery without angiographic evidence of atherosclerotic disease. IVUS evaluation revealed an 18 mm long and 12.2 x 10.8 mm wide aneurysm without atherosclerosis, thrombus or calcification. Pulsed wave Doppler showed significant reduction of LAD flow reserve, which normalized after successful obliteration of the aneurysm with polytetrafluoroethylene (PTFE)-covered stent implantation. Severe in-stent graft restenosis was found at 7-month angiographic and intravascular ultrasound follow-up, which was managed successfully with minimally invasive direct coronary bypass surgery. The patient did well, without symptoms over the following year.


Assuntos
Aneurisma Coronário/etiologia , Infarto do Miocárdio/complicações , Implante de Prótese Vascular , Materiais Revestidos Biocompatíveis/uso terapêutico , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/terapia , Eletrocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Politetrafluoretileno/uso terapêutico , Stents , Ultrassonografia Doppler Dupla , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA