Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Nucl Cardiol ; 29(3): 1003-1017, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33094471

RESUMO

BACKGROUND: Cardiac positron emission tomography/magnetic resonance imaging (PET/MRI) can assess various cardiovascular diseases. In this study, we intra-individually compared right (RV) and left ventricular (LV) parameters obtained from dual-tracer PET/MRI scan. METHODS: In 22 patients with coronary heart disease (69 ± 9 years) dynamic [13N]NH3 (NH3) and [18F]FDG (FDG) PET scans were acquired. The first 2 minutes were used to calculate LV and RV first-pass ejection fraction (FPEF). Additionally, LV end-systolic (LVESV) and end-diastolic (LVEDV) volume and ejection fraction (LVEF) were calculated from the early (EP) and late-myocardial phases (LP). MRI served as a reference. RESULTS: RVFPEF and LVFPEF from FDG and NH3 as well as RVEF and LVEF from MRI were (28 ± 11%, 32 ± 15%), (32 ± 11%, 41 ± 14%) and (42 ± 16%, 45 ± 19%), respectively. LVESV, LVEDV and LVEF from EP FDG and NH3 in 8 and 16 gates were [71 (15 to 213 mL), 98 (16 to 241 mL), 32 ± 17%] and [50 (17 to 206 mL), 93 (13 to 219 mL), 36 ± 17%] as well as [60 (19 to 360 mL), 109 (56 to 384 mL), 41 ± 22%] and [54 (16 to 371 mL), 116 (57 to 431 mL), 46 ± 24%], respectively. Moreover, LVESV, LVEDV and LVEF acquired from LP FDG and NH3 were (85 ± 63 mL, 138 ± 63 mL, 47 ± 19%) and (79 ± 56 mL, 137 ± 63 mL, 47 ± 20%), respectively. The LVESV, LVEDV from MRI were 93 ± 66 mL and 153 ± 71 mL, respectively. Significant correlations were observed for RVFPEF and LVFPEF between FDG and MRI (R = .51, P = .01; R = .64, P = .001), respectively. LVESV, LVEDV, and LVEF revealed moderate to strong correlations to MRI when they acquired from EP FDG and NH3 in 16 gates (all R > .7, P = .000). Similarly, all LV parameters from LP FDG and NH3 correlated good to strongly positive with MRI (all R > .7, and P < .001), except EDV from NH3 weakly correlated to EDV of MRI (R = .54, P < .05). Generally, Bland-Altman plots showed good agreements between PET and MRI. CONCLUSIONS: Deriving LV and RV functional values from various phases of dynamic NH3 and FDG PET is feasible. These results could open a new perspective for further clinical applications of the PET examinations.


Assuntos
Doença da Artéria Coronariana , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Tomografia Computadorizada por Raios X
2.
Obes Surg ; 30(11): 4192-4197, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32564309

RESUMO

INTRODUCTION/PURPOSE: Weight regain and weight loss failure after bariatric surgery are important issues that may require a weight regain procedure. Three-dimensional-computed tomography (3D-CT) is a well-established method allowing exact measurements of pouch volume. The aims of this study were to prove the applicability of swallow MRI as a non-ionizing procedure and compare it to 3D-CT in patients after weight regain procedures following RYGB. MATERIALS AND METHODS: Twelve post-RYGB patients who had a follow-up operation for weight regain before 12/2017 were included in this prospective study. Swallow MRI and 3D-CT were performed in each patient to evaluate the size of the anastomosis, pouch volume, and intrathoracic pouch migration (ITM). RESULTS: Mean pouch volume in swallow MRI and 3D-CT were 40.4 ± 21.0 ml and 43.5 ± 30.2 ml, respectively (p = 0.83), and pouch diameter at the maximal distention was 35.3 ± 5.9 ml (MRI) and 31.0 ± 10.0 ml (CT) (p = 0.16). The rate of ITM was 75% in both examinations (p = 1.0). CONCLUSION: Swallow MRI is a valid method for the assessment of pouch volume in different phases of the swallowing process and is comparable to 3D-CT. The diagnosis of ITM using swallow MRI was equal to 3D-CT.


Assuntos
Derivação Gástrica , Hérnia Hiatal , Obesidade Mórbida , Humanos , Imageamento por Ressonância Magnética , Obesidade Mórbida/cirurgia , Estudos Prospectivos , Reoperação
3.
Acad Radiol ; 27(2): 188-197, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31053482

RESUMO

RATIONALE AND OBJECTIVES: Hybrid positron emission tomography-magnetic resonance (PET-MR) is a novel imaging technology that enables a comprehensive assessment of myocardial viability. The aim of this study was to intra-individually compare simultaneously acquired viability parameters from MRI and PET to determine complementary and redundant information. MATERIALS AND METHODS: Thirty-nine patients with ischemic heart disease (IHD) underwent cardiac PET-MR for myocardial viability assessment. Cardiac magnetic resonance (CMR), including late gadolinium enhancement (LGE), and PET, including a dynamic dual-tracer acquisition of [13N]ammonia ([13N]NH3)/[18F]fluorodeoxyglucose ([18F]FDG), were performed simultaneously. Allocation, extent, and transmural degree of left ventricular (LV) scars were measured from LGE. Perfusion, viability, and hibernation were assessed by PET. RESULTS: A comparison of scar location revealed six more areas of infarction on MR than on PET. Mean LV scarring by CMR was 14% (range, 2% to 42%) and 14% (range, 1% to 46%) by PET (CMR vs. PET: p = 0.9). An intra-individual comparison of scarring showed a good inter-method correlation (r = 0.7), which was also evident in the subgroup with low ejection fraction (EF) (r = 0.6). Hibernation and transmural degree of scars showed a moderate to weak correlation (r = 0.4), which was even worse in the low EF group (r = 0.1). CONCLUSIONS: In patients with IHD, there was a good correlation between PET and CMR for the LV scar extent using hybrid cardiac PET-MR. The degree of transmural scarring by CMR showed no correlation to PET hibernation. Therefore, cardiac PET-MR might be a suitable tool for a comprehensive assessment of myocardial viability if used to predict response to cardiac reperfusion strategies.


Assuntos
Cicatriz , Isquemia Miocárdica , Cicatriz/diagnóstico por imagem , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Isquemia Miocárdica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Função Ventricular Esquerda
4.
J Magn Reson Imaging ; 50(4): 1326-1335, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30892777

RESUMO

BACKGROUND: Sympathetic reinnervation after heart transplantation (HTX) is a known phenomenon, which has an impact on patient heart rate variability and exercise capacity. The impact of reinnervation on myocardial structure has not been evaluated yet. PROPOSE: To evaluate the feasibility of simultaneous imaging of cardiac reinnervation and cardiac structure using a hybrid PET/MRI system. STUDY TYPE: Prospective / pilot study. SUBJECTS: Ten patients, 4-21 years after cardiac transplantation. FIELD STRENGTH/SEQUENCE: 3 T hybrid PET/MRI system. Cine SSFP, T1 mapping (modified Look-Locker inversion recovery sequence) pre/postcontrast as well as dynamic [11 C]meta-hydroxyephedrine ([11 C]mHED) PET. ASSESSMENT: All MRI and PET parameters were evaluated by experienced readers using dedicated postprocessing software packages for cardiac MRI and PET. For all parameters a 16-segment model for the left ventricle was applied. STATISTICAL TESTS: Mann-Whitney U-test; Spearman correlations. RESULTS: Thirty-six of 160 myocardial segments showed evidence of reinnervation by PET. On a segment-based analysis, mean native T1 relaxation times were nonsignificantly altered in segments with evidence of reinnervation (1305 ± 151 msec vs. 1270 ± 112 msec; P = 0.1), whereas mean extracellular volume (ECV) was significantly higher in segments with evidence of reinnervation (35.8 ± 11% vs. 30.9 ± 7%; P = 0.019). There were no significant differences in wall motion (WM) and wall thickening (WT) between segments with or without reinnervation (mean WM: 7.6 ± 4 mm vs. group B: 9.3 ± 7 mm [P = 0.13]; WT: 79 ± 63% vs. 94 ± 74% [P = 0.27]) under resting conditions. DATA CONCLUSION: The assessment of cardiac reinnervation using a hybrid PET/MRI system is feasible. Segments with evidence of reinnervation by PET showed nonsignificantly higher T1 relaxation times and a significantly higher ECV, suggesting a higher percentage of diffuse fibrosis in these segments, without impairment of rest WM and WT. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019;50:1326-1335.


Assuntos
Transplante de Coração , Coração/inervação , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Sistema Nervoso Simpático/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Adulto Jovem
5.
J Nucl Cardiol ; 26(4): 1107-1118, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-29168158

RESUMO

OBJECTIVE: To evaluate the frequency of artifacts in MR-based attenuation correction (AC) maps and their impact on the quantitative accuracy of PET-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined PET/MR imaging. METHODS: Myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion (13N-NH3: 813 ± 86 MBq) and metabolism (18F-FDG: 335 ± 38 MBq). All acquisitions were performed using a fully-integrated PET/MR system, with standard DIXON-attenuation correction (DIXON-AC) mapping for each PET scan. All AC maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (TI). Misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. The effects of the AC artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. RESULTS: Average respiratory misalignment of (7 ± 4) mm of the PET-emission data and the AC maps was observed in 18 (90%) patients. Substantial changes in the lung volumes of the AC maps were observed in the test-retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). Susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had TI artifacts. Average differences of 14 ± 10% were observed for PET images reconstructed with the artifactual AC maps. The combined artifact effects caused false-positive findings in three (15%) patients. CONCLUSION: Standard DIXON-AC maps must be examined carefully for artifacts and misalignment effects prior to AC correction of cardiac PET/MRI studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the PET data.


Assuntos
Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Feminino , Fluordesoxiglucose F18 , Insuficiência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Imagem de Perfusão do Miocárdio , Miocárdio/patologia , Distribuição Normal , Estudos Retrospectivos
7.
Eur J Nucl Med Mol Imaging ; 43(8): 1503-12, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26816195

RESUMO

PURPOSE: PET with (18)F-FDG has the potential to assess vascular macrophage metabolism. (18)F-FDG is most often used in combination with contrast-enhanced CT to localize increased metabolism to specific arterial lesions. Novel (18)F-FDG PET/MRI hybrid imaging shows high potential for the combined evaluation of atherosclerotic plaques, due to the superior morphological conspicuity of plaque lesions. The purpose of this study was to evaluate the reliability and accuracy of (18)F-FDG PET/MRI uptake quantification compared to PET/CT as a reference standard in patients with carotid atherosclerotic plaques. METHODS: The study group comprised 34 consecutive oncological patients with carotid plaques who underwent both PET/CT and PET/MRI with (18)F-FDG on the same day. The presence of atherosclerotic plaques was confirmed by 3 T MRI scans. Maximum standardized uptake values (SUVmax) for carotid plaque lesions and the average SUV of the blood pool within the adjacent internal jugular vein were determined and target-to-blood ratios (TBRs, plaque to blood pool) were calculated. RESULTS: Atherosclerotic lesions with maximum colocalized focal FDG uptake were assessed in each patient. SUVmax values of carotid plaque lesions were significantly lower on PET/MRI than on PET/CT (2.3 ± 0.6 vs. 3.1 ± 0.6; P < 0.01), but were significantly correlated between PET/CT and PET/MRI (Spearman's r = 0.67, P < 0.01). In contrast, TBRmax values of plaque lesions were similar on PET/MRI and on PET/CT (2.2 ± 0.3 vs. 2.2 ± 0.3; P = 0.4), and again were significantly correlated between PET/MRI and PET/CT (Spearman's r = 0.73, P < 0.01). Considering the increasing trend in SUVmax and TBRmax values from early to delayed imaging time-points on PET/CT and PET/MRI, respectively, with continuous clearance of radioactivity from the blood, a slight underestimation of TBRmax values may also be expected with PET/MRI compared with PET/CT. CONCLUSION: SUVmax and TBRmax values are widely accepted reference parameters for estimation of the radioactivity of atherosclerotic plaques on PET/CT. However, due to a systematic underestimation of SUVmax and TBRmax with PET/MRI, the optimal cut-off values indicating the presence of inflamed plaque tissue need to be newly defined for PET/MRI.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética , Placa Aterosclerótica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Idoso de 80 Anos ou mais , Doenças das Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA