Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-11346729

RESUMO

OBJECTIVE: The hemodynamic effects of local anesthetic administration with and without a vasoconstrictor were compared by using laser Doppler flowmetry. STUDY DESIGN: Seventeen people participated in a single study session in which they were given 2 intraoral injections. The injections, which were administered in random order, consisted of 1.8 mL lidocaine (2%) with epinephrine (1:100,000) and mepivacaine (3%). Hemodynamic parameters consisting of blood pressure, heart rate, and laser Doppler flowmetry were reordered at regular intervals. RESULTS: The laser Doppler flowmeter detected changes in the peripheral perfusion of the finger that were not detected by changes in blood pressure and heart rate. The greatest change was associated with anxiety and occurred just before the injection. The inclusion of epinephrine in the local anesthetic resulted in a persistence of these changes. CONCLUSION: This investigation has confirmed the sensitivity of laser Doppler flowmetry as an investigational tool for assessing hemodynamic changes associated with anxiety and the administration of local anesthesia.


Assuntos
Anestésicos Locais/administração & dosagem , Pressão Sanguínea/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Fluxometria por Laser-Doppler , Ansiedade ao Tratamento Odontológico/fisiopatologia , Método Duplo-Cego , Eletrocardiografia , Epinefrina/administração & dosagem , Dedos/irrigação sanguínea , Hemodinâmica , Humanos , Injeções , Lidocaína/administração & dosagem , Mepivacaína/administração & dosagem , Bloqueio Nervoso , Oximetria , Fluxo Sanguíneo Regional/efeitos dos fármacos , Sensibilidade e Especificidade , Estatística como Assunto , Vasoconstritores/administração & dosagem
2.
Radiology ; 213(1): 141-9, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10540654

RESUMO

PURPOSE: To validate a dynamic single-section computed tomographic (CT) method to measure cerebral blood volume (CBV) and cerebral blood flow (CBF) by using a noncarotid artery as the input and to demonstrate the feasibility of this method in a pilot series of patients. MATERIALS AND METHODS: Twelve dynamic contrast material-enhanced CT studies were performed in beagles. CBV, CBF, and mean transit time (MTT) values were calculated by using an internal carotid artery (ICA) and a noncarotid artery as the input artery to the brain. Patient studies with use of the radial artery as the input were performed (a) repetitively in two patients after subarachnoid hemorrhage, (b) in a patient with a symptomatic ICA occlusion before and after the intravenous injection of 1 g of acetazolamide, and (c) in a patient with a malignant brain tumor. RESULTS: Linear regression analyses revealed highly significant correlations (P < .001) between CBV (r, 0.98; slope, 0.96), CBF (r, 0.89; slope, 0.87), and MTT (r, 0.80; slope, 0.76) values calculated with the ICA and the noncarotid inputs. The CT-derived patient data correlated well with ancillary clinical and neuroradiologic findings. CONCLUSION: Dynamic single-section CT scanning to measure CBV and CBF on the basis of a noncarotid input is a highly accessible and cost-effective blood flow measurement technique.


Assuntos
Volume Sanguíneo , Circulação Cerebrovascular , Tomografia Computadorizada por Raios X , Animais , Velocidade do Fluxo Sanguíneo , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/fisiopatologia , Artéria Carótida Interna , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/fisiopatologia , Cães , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA