Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Nucl Med ; 61(6): 920-927, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31712324

RESUMO

18F-PI-2620 is a next-generation tau PET tracer that has demonstrated ability to image the spatial distribution of suspected tau pathology. The objective of this study was to assess the tracer biodistribution, dosimetry, and quantitative methods of 18F-PI-2620 in the human brain. Full kinetic modeling to quantify tau load was investigated. Noninvasive kinetic modeling and semiquantitative methods were evaluated against the full tracer kinetics. Finally, the reproducibility of PET measurements from test and retest scans was assessed. Methods: Three healthy controls (HCs) and 4 Alzheimer disease (AD) subjects underwent 2 dynamic PET scans, including arterial sampling. Distribution volume ratio (DVR) was estimated using full tracer kinetics (reversible 2-tissue-compartment [2TC] model and Logan graphical analysis [LGA]) and noninvasive kinetic models (noninvasive LGA [NI-LGA] and the multilinear reference tissue model [MRTM2]). SUV ratio (SUVR) was determined at different imaging windows after injection. The correlation between DVR and SUVR, effect size (Cohen's d), and test-retest variability (TRV) were evaluated. Additionally, 6 HCs received 1 tracer administration and underwent whole-body PET for dosimetry calculation. Organ doses and the whole-body effective dose were calculated using OLINDA 2.0. Results: A strong correlation was found across different kinetic models (R2 > 0.97) and between DVR(2TC) and SUVR between 30 and 90 min, with an R2 of more than 0.95. Secular equilibrium was reached at around 40 min after injection in most regions and subjects. TRV and effect size for SUVR across different regions were similar at 30-60 min (TRV, 3.8%; Cohen's d, 3.80), 45-75 min (TRV, 4.3%; Cohen's d, 3.77) and 60-90 min (TRV, 4.9%; Cohen's d, 3.73) and increased at later time points. Elimination was via the hepatobiliary and urinary systems. The whole-body effective dose was 33.3 ± 2.1 µSv/MBq for an adult female and 33.1 ± 1.4 µSv/MBq for an adult male, with a 1.5-h urinary bladder voiding interval. Conclusion:18F-PI-2620 exhibits fast kinetics, suitable dosimetry, and low TRV. DVR measured using the 2TC model with arterial sampling correlated strongly with DVR measured by NI-LGA, MRTM2, and SUVR. SUVR can be used for 18F-PI-2620 PET quantification of tau deposits, avoiding arterial blood sampling. Static 18F-PI-2620 PET scans between 45 and 75 min after injection provide excellent quantification accuracy, a large effect size, and low TRV.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Encéfalo/metabolismo , Radioisótopos de Flúor/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Piridinas/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Proteínas tau/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Distribuição Tecidual
2.
Eur J Nucl Med Mol Imaging ; 46(10): 2178-2189, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31264169

RESUMO

PURPOSE: Tau deposition is a key pathological feature of Alzheimer's disease (AD) and other neurodegenerative disorders. The spreading of tau neurofibrillary tangles across defined brain regions corresponds to the observed level of cognitive decline in AD. Positron-emission tomography (PET) has proved to be an important tool for the detection of amyloid-beta (Aß) aggregates in the brain, and is currently being explored for detection of pathological misfolded tau in AD and other non-AD tauopathies. Several PET tracers targeting tau deposits have been discovered and tested in humans. Limitations have been reported, especially regarding their selectivity. METHODS: In our screening campaign we identified pyrrolo[2,3-b:4,5-c']dipyridine core structures with high affinity for aggregated tau. Further characterization showed that compounds containing this moiety had significantly reduced monoamine oxidase A (MAO-A) binding compared to pyrido[4,3-b]indole derivatives such as AV-1451. RESULTS: Here we present preclinical data of all ten fluoropyridine regioisomers attached to the pyrrolo[2,3-b:4,5-c']dipyridine scaffold, revealing compounds 4 and 7 with superior properties. The lead candidate [18F]PI-2620 (compound 7) displayed high affinity for tau deposits in AD brain homogenate competition assays. Specific binding to pathological misfolded tau was further demonstrated by autoradiography on AD brain sections (Braak I-VI), Pick's disease and progressive supranuclear palsy (PSP) pathology, whereas no specific tracer binding was detected on brain slices from non-demented donors. In addition to its high affinity binding to tau aggregates, the compound showed excellent selectivity with no off-target binding to Aß or MAO-A/B. Good brain uptake and fast washout were observed in healthy mice and non-human primates. CONCLUSIONS: Therefore, [18F]PI-2620 was selected for clinical validation.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Inibidores da Monoaminoxidase/síntese química , Tomografia por Emissão de Pósitrons/métodos , Piridinas/síntese química , Compostos Radiofarmacêuticos/síntese química , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Radioisótopos de Flúor/farmacocinética , Humanos , Macaca mulatta , Camundongos , Monoaminoxidase/metabolismo , Inibidores da Monoaminoxidase/farmacocinética , Ligação Proteica , Piridinas/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética
3.
Cancer Res ; 79(4): 853-863, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30401715

RESUMO

The cell's endogenous antioxidant system is vital to maintenance of redox homeostasis. Despite its central role in normal and pathophysiology, no noninvasive tools exist to measure this system in patients. The cystine/glutamate antiporter system xc - maintains the balance between intracellular reactive oxygen species and antioxidant production through the provision of cystine, a key precursor in glutathione biosynthesis. Here, we show that tumor cell retention of a system xc --specific PET radiotracer, (S)-4-(3-[18F]fluoropropyl)-L-glutamic acid ([18F]FSPG), decreases in proportion to levels of oxidative stress following treatment with a range of redox-active compounds. The decrease in [18F]FSPG retention correlated with a depletion of intracellular cystine resulting from increased de novo glutathione biosynthesis, shown through [U-13C6, U-15N2]cystine isotopic tracing. In vivo, treatment with the chemotherapeutic doxorubicin decreased [18F]FSPG tumor uptake in a mouse model of ovarian cancer, coinciding with markers of oxidative stress but preceding tumor shrinkage and decreased glucose utilization. Having already been used in pilot clinical trials, [18F]FSPG PET could be rapidly translated to the clinic as an early redox indicator of tumor response to treatment. SIGNIFICANCE: [18F]FSPG PET imaging provides a sensitive noninvasive measure of tumor redox status and provides an early marker of tumor response to therapy.See related commentary by Lee et al., p. 701.


Assuntos
Sistema y+ de Transporte de Aminoácidos/metabolismo , Cistadenocarcinoma Seroso/patologia , Radioisótopos de Flúor/metabolismo , Glutamatos/metabolismo , Neoplasias Ovarianas/patologia , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/metabolismo , Acetilcisteína/farmacologia , Animais , Apoptose , Proliferação de Células , Cistadenocarcinoma Seroso/diagnóstico por imagem , Cistadenocarcinoma Seroso/tratamento farmacológico , Cistadenocarcinoma Seroso/metabolismo , Feminino , Sequestradores de Radicais Livres/farmacologia , Humanos , Metabolômica , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/tratamento farmacológico , Neoplasias Ovarianas/metabolismo , Oxirredução , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto , terc-Butil Hidroperóxido/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA