Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Int J Numer Method Biomed Eng ; 39(9): e3753, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37424171

RESUMO

The implant of self-expandable Ni-Ti stents for the treatment of peripheral diseases has become an established medical practice. However, the reported failure in clinics highlights the open issue of the fatigue characterization of these devices. One of the most common approaches for calculating the Ni-Ti fatigue limit (commonly defined in terms of mean and alternate strain for a fixed number of cycles) consists of using surrogate specimens which replicate the strain distributions of the final device but in simplified geometries. The main drawback lies in the need for computational models to determine the local distribution and, hence, interpret the experimental results. This study aims at investigating the role of different choices in the model preparation, such as the mesh refinement and the element formulation, on the output of the fatigue analysis. The analyses show a strong dependency of the numerical results on modeling choices. The use of linear reduced elements enriched by a layer of membrane elements is successful to increase the accuracy of the results, especially when coarser meshes are used. Due to material nonlinearity and stent complex geometries, for the same loading conditions and element type, (i) different meshes result in different couples of mean and amplitude strains and (ii) for the same mesh, the position of the maximum mean strain is not coincident with the maximum amplitude, making difficult the selection of the limit values.


Assuntos
Níquel , Stents , Estresse Mecânico , Titânio , Análise de Elementos Finitos
2.
J Mech Behav Biomed Mater ; 113: 104142, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33125952

RESUMO

Ni-Ti stents fatigue strength assessment requires a multi-factorial complex integration of applied loads, material and design and is of increasing interest. In this work, a coupled experimental-numerical method for the multi-axial fatigue strength assessment is proposed and verified for two different stent geometries that resemble commercial products. Particular attention was paid to the identification of the material fatigue limit curve. The common approach for the Ni-Ti stents fatigue assessment based on the von Mises yield criterion was proven unsuitable for a realistic fatigue strength assessment. On the other hand, critical plane-based criteria were more representative of the experimental outcomes regardless of stent design.


Assuntos
Níquel , Titânio , Fadiga , Humanos , Stents
3.
Interface Focus ; 11(1): 20190123, 2021 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-33343873

RESUMO

An acute ischaemic stroke appears when a blood clot blocks the blood flow in a cerebral artery. Intra-arterial thrombectomy, a mini-invasive procedure based on stent technology, is a mechanical available treatment to extract the clot and restore the blood circulation. After stent deployment, the clot, trapped in the stent struts, is pulled along with the stent towards a receiving catheter. Recent clinical trials have confirmed the effectiveness and safety of mechanical thrombectomy. However, the procedure requires further investigation. The aim of this study is the development of a numerical finite-element-based model of the thrombectomy procedure. In vitro thrombectomy tests are performed in different vessel geometries and one simulation for each test is carried out to verify the accuracy and reliability of the proposed numerical model. The results of the simulations confirm the efficacy of the model to replicate all the experimental setups. Clot stress and strain fields from the numerical analysis, which vary depending on the geometric features of the vessel, could be used to evaluate the possible fragmentation of the clot during the procedure. The proposed in vitro/in silico comparison aims at assessing the applicability of the numerical model and at providing validation evidence for the specific in vivo thrombectomy outcomes prediction.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA