J Vasc Surg Venous Lymphat Disord ; 12(2): 101687, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37708934

RESUMO

OBJECTIVE: The objective of this study was to help guide inferior vena cava (IVC) filter choices by better understanding the retrieval characteristics, complications, and total costs between two commonly used IVC filters. METHODS: All patients who underwent retrieval or attempted retrieval of Denali (Bard Peripheral Vascular) or Option (Argon Medical Devices) IVC filters were identified between March 2016 and October 2021 at a single tertiary care center. Those with imaging studies that permitted evaluation of filter placement, presence or degree of tilt, and/or hooking of the filter into the IVC wall were included in the present study. Filter retrieval success, number of attempts, use of advanced techniques, and fluoroscopy and procedural times were recorded and compared between the two filters. RESULTS: A total of 87 patients presented for retrieval of 52 Denali and 35 Option Elite filters during the study period. Denali filters were more likely to be successfully retrieved at the first attempt (94% vs 77%; P = .019). The procedural and fluoroscopy times were shorter for Denali filters (29 minutes vs 63 minutes [P < .001] and 7 minutes vs 25 minutes [P < .001], respectively). Denali filters were less likely to be significantly tilted (≥15○) at retrieval (12% vs 29%; P < .001) or to have the filter hook embedded in the IVC wall (6% vs 40%; P < .001). Tilting of the filter of ≥15○ had no significant effects on the retrieval success rate (no tilt or tilt <15○ vs tilt of ≥15○: 98% vs 100%; P = .58). In contrast, filter hook penetration into the IVC wall significantly reduced successful recovery (41% vs 99%; P < .001). CONCLUSIONS: The findings from this study suggest that although the filter designs are similar, a benefit exists in the ease of retrievability of the Denali over the Option filter. We found that tilting and hooking of the filter in the IVC wall occurred significantly more with the Option filter. These factors likely made retrieval more difficult and contributed to the longer procedure and fluoroscopy times.


Assuntos
Filtros de Veia Cava , Humanos , Fatores de Tempo , Remoção de Dispositivo/métodos , Implantação de Prótese , Veia Cava Inferior/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA