Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Biochem ; 687: 115429, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38113981

RESUMO

Microcystin-producing cyanobacterial blooms are a global issue threatening drinking water supplies and recreation on lakes and beaches. Direct measurement of microcystins is the only way to ensure waters have concentrations below guideline concentrations; however, analyzing water for microcystins takes several hours to days to obtain data. We tested LightDeck Diagnostics' bead beater cell lysis and two versions of the quantification system designed to give microcystin concentrations within 20 min and compared it to the standard freeze-thaw cycle lysis method and ELISA quantification. The bead beater lyser was only 30 % effective at extracting microcystins compared to freeze-thaw. When considering freeze-thaw samples analyzed in 2021, there was good agreement between ELISA and LightDeck version 2 (n = 152; R2 = 0.868), but the LightDeck slightly underestimated microcystins (slope of 0.862). However, we found poor relationships between LightDeck version 2 and ELISA in 2022 (n = 49, slopes 0.60 to 1.6; R2 < 0.6) and LightDeck version 1 (slope = 1.77 but also a high number of less than quantifiable concentrations). After the quantification issues are resolved, combining the LightDeck system with an already-proven rapid lysis method (such as microwaving) will allow beach managers and water treatment operators to make quicker, well-informed decisions.


Assuntos
Técnicas Biossensoriais , Cianobactérias , Microcistinas/análise , Microcistinas/metabolismo , Proliferação Nociva de Algas , Lagos/análise
2.
Cytometry B Clin Cytom ; 92(6): 451-455, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-25917935

RESUMO

BACKGROUND: Point-of-care (POC) CD4 T-cell counting is increasingly recognized as providing improved linkage-to-care during management of HIV infection, particularly in resource-limited settings where disease burden is highest. This study evaluated prototype POC CD4 T-cell counters from MBio Diagnostics in the context of low CD4 count, hospitalized patients in Mozambique. This study measured system performance when presented with challenging, low count samples from HIV/AIDS patients with acute illnesses resulting in hospitalization. METHODS: Forty whole blood samples were collected from donors on the medical service at Maputo Central Hospital and absolute CD4 counts were generated on the MBio CD4 system and a reference laboratory using flow cytometry. RESULTS: The mean and median CD4 counts by the flow cytometry reference were 173 and 80 cells/µL, respectively. Correlation between the MBio CD4 System and the reference was good. Bland-Altman analysis showed a mean bias of +15 cells/µL (+9 to +21 cells/µL, 95% CI), and limits of agreement of -47 to 77 cells/µL. For samples with counts >100 cells/µL (N = 14), the mean coefficient of variation was 7.3%. For samples with counts <50 cells/µL, mean absolute bias of replicate samples was 4.8 cells/µL. When two MBio readers were compared, Bland-Altman bias was -4 cells/µL (-13 to +6 cells/µL, 95% CI), and limits of agreement of -63 and +55 cells/µL. CONCLUSIONS: The MBio System holds promise as a POC system for quantitation of CD4 T cells in resource-limited settings given system throughput (80-100 cartridges/day), design simplicity, and ease-of-use. © 2015 International Clinical Cytometry Society.


Assuntos
Contagem de Linfócito CD4/instrumentação , Linfócitos T CD4-Positivos/imunologia , Citometria de Fluxo/instrumentação , Infecções por HIV/diagnóstico , Imunofenotipagem/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Complexo CD3/imunologia , Linfócitos T CD4-Positivos/virologia , Estudos de Casos e Controles , Computadores de Mão/economia , Computadores de Mão/provisão & distribuição , Países em Desenvolvimento , Citometria de Fluxo/economia , Infecções por HIV/imunologia , Infecções por HIV/virologia , Humanos , Imunofenotipagem/instrumentação , Subpopulações de Linfócitos/imunologia , Subpopulações de Linfócitos/virologia , Aplicativos Móveis/economia , Aplicativos Móveis/provisão & distribuição , Moçambique , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA