Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Front Oncol ; 13: 1161738, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37554160

RESUMO

Objectives: Colorectal cancer (CRC) is a serious challenge for the health system. In 2022 CRC represented 8% of cancer diagnoses in the United States. 30% of patients already show metastases at the initial tumor staging. The majority of these metastases are sited in the liver. According to their extension and the status of the tumor colorectal liver metastases can be treated in several ways, with hepatic resection being the gold-standard. Contrast-enhanced computed tomography (CE-CT), positron emission tomography/computed tomography (PET/CT) and magnetic resonance imaging (MRI) can be used for evaluation of resectability of these liver metastases. The aim of this study is to assess the most economic imaging modality for detecting liver metastases eligible for hepatic resection by analyzing their cost-effectiveness. Materials and methods: In our study, a Markov state transition model was built to calculate the quality-adjusted life years (QALYs) and overall costs for each diagnostic strategy in accord with the stated input values obtained from scientific research. Further, probabilistic sensitivity analyses by means of Monte Carlo simulations were performed to consider possible model uncertainties. For evaluation of the cost-effectiveness on an economic threshold, the Willingness-to-pay (WTP) was set at $ 100,000. The applied values and the calculated results are based on the U.S. healthcare system. Results: CE-CT led to overall costs of $ 42,874.02 and 8.47 QALYs, whereas MRI led to $ 40,863.65 and 8.50 QALYs. PET/CT resulted in overall costs of $ 43,216.74 and 8.48 QALYs. Therefore, MRI was determined to be the dominant strategy in the model. According to the performed sensitivity analyses, MRI remained cost-effective over a wide range of WTPs. Conclusion: In conclusion, according to our analysis, MRI is the dominant strategy for detecting hepatic metastases eligible for hepatic resection in colorectal cancer.

2.
Eur J Radiol ; 163: 110803, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37004464

RESUMO

OBJECTIVES: Colorectal cancers (CRC) are among the world's most prevailing cancer entities. In a third of all cases, the patients have already developed distant metastases - mainly in the liver - at the time of detection. Colorectal liver metastases (CRLM) can be treated by surgical resection or, as is possible in most cases, by percutaneous ablation. For selecting the liver metastases eligible for radiofrequency ablation (RFA) or microwave ablation (MWA), the common imaging modalities are magnetic resonance imaging (MRI), positron emission tomography/computed tomography (PET/CT), and contrast-enhanced computed tomography (CE-CT). This study aims to evaluate those imaging modalities for selecting liver lesions eligible for ablation according to their long-term cost-effectiveness. MATERIALS AND METHODS: A Markov model was applied, calculating quality-adjusted life years (QALYs) and accumulative costs for every diagnostic strategy, according to predefined input parameters obtained from published research. Further, sensitivity analyses were executed to prove the certainty of the calculations by running Monte-Carlo simulations with 30,000 reiterations. The Willingness-to-pay (WTP) is at $ 100,000. All calculations are based on the U.S. healthcare system. RESULTS: CE-CT caused cumulative costs of $ 31,940.98 and 8,99 QALYs, whereas MRI caused $ 32,070.83 and 9,01 QALYs. PET/CT caused cumulative costs of $ 33,013.21 and 8,99 QALYs. CONCLUSION: In conclusion, according to our analysis, MRI is the most cost-effective strategy for detecting liver metastases eligible for ablation and therefore should be seen as the gold standard.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Análise Custo-Benefício , Análise de Custo-Efetividade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Tomografia por Emissão de Pósitrons/métodos
3.
Cancers (Basel) ; 14(9)2022 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-35565365

RESUMO

BACKGROUND: For patients with solid renal masses, a precise differentiation between malignant and benign tumors is crucial for forward treatment management. Even though MRI and CT are often deemed as the gold standard in the diagnosis of solid renal masses, CEUS may also offer very high sensitivity in detection. The aim of this study therefore was to evaluate the effectiveness of CEUS from an economical point of view. METHODS: A decision-making model based on a Markov model assessed expenses and utilities (in QALYs) associated with CEUS, MRI and CT. The utilized parameters were acquired from published research. Further, a Monte Carlo simulation-based deterministic sensitivity analysis of utilized variables with 30,000 repetitions was executed. The willingness-to-pay (WTP) is at USD 100,000/QALY. RESULTS: In the baseline, CT caused overall expenses of USD 10,285.58 and an efficacy of 11.95 QALYs, whereas MRI caused overall expenses of USD 7407.70 and an efficacy of 12.25. Further, CEUS caused overall expenses of USD 5539.78, with an efficacy of 12.44. Consequently, CT and MRI were dominated by CEUS, and CEUS remained cost-effective in the sensitivity analyses. CONCLUSIONS: CEUS should be considered as a cost-effective imaging strategy for the initial diagnostic workup and assessment of solid renal masses compared to CT and MRI.

4.
Mov Disord ; 36(4): 883-894, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33245166

RESUMO

BACKGROUND: Neuroinflammation has received growing interest as a therapeutic target in neurodegenerative disorders, including 4-repeat tauopathies. OBJECTIVES: The aim of this cross-sectional study was to investigate 18 kDa translocator protein positron emission tomography (PET) as a biomarker for microglial activation in the 4-repeat tauopathies corticobasal degeneration and progressive supranuclear palsy. METHODS: Specific binding of the 18 kDa translocator protein tracer 18 F-GE-180 was determined by serial PET during pharmacological depletion of microglia in a 4-repeat tau mouse model. The 18 kDa translocator protein PET was performed in 30 patients with corticobasal syndrome (68 ± 9 years, 16 women) and 14 patients with progressive supranuclear palsy (69 ± 9 years, 8 women), and 13 control subjects (70 ± 7 years, 7 women). Group comparisons and associations with parameters of disease progression were assessed by region-based and voxel-wise analyses. RESULTS: Tracer binding was significantly reduced after pharmacological depletion of microglia in 4-repeat tau mice. Elevated 18 kDa translocator protein labeling was observed in the subcortical brain areas of patients with corticobasal syndrome and progressive supranuclear palsy when compared with controls and was most pronounced in the globus pallidus internus, whereas only patients with corticobasal syndrome showed additionally elevated tracer binding in motor and supplemental motor areas. The 18 kDa translocator protein labeling was not correlated with parameters of disease progression in corticobasal syndrome and progressive supranuclear palsy but allowed sensitive detection in patients with 4-repeat tauopathies by a multiregion classifier. CONCLUSIONS: Our data indicate that 18 F-GE-180 PET detects microglial activation in the brain of patients with 4-repeat tauopathy, fitting to predilection sites of the phenotype. The 18 kDa translocator protein PET has a potential for monitoring neuroinflammation in 4-repeat tauopathies. © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Assuntos
Doença de Alzheimer , Paralisia Supranuclear Progressiva , Tauopatias , Idoso , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Estudos Transversais , Feminino , Humanos , Masculino , Camundongos , Pessoa de Meia-Idade , Paralisia Supranuclear Progressiva/diagnóstico por imagem , Paralisia Supranuclear Progressiva/genética , Tauopatias/diagnóstico por imagem , Tauopatias/genética , Proteínas tau/genética , Proteínas tau/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA