Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Equine Vet Sci ; 126: 104492, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37072071

RESUMO

Acquisition of magnetic resonance images of the equine limb is still sometimes conducted under general anaesthesia. Despite low-field systems allow the use of standard anaesthetic equipment, possible interferences of the extensive electronic componentry of advanced anaesthetic machines on image quality is unknown. This prospective, blinded, cadaver study investigated the effects of seven standardised conditions (Tafonius positioned as in clinical cases, Tafonius on the boundaries of the controlled area, anaesthetic monitoring only, Mallard anaesthetic machine, Bird ventilator, complete electronic silence in the room (negative control), source of electronic interference [positive control]) on image quality through the acquisition of 78 sequences using a 0.31T equine MRI scanner. Images were graded with a 4-point scoring system, where 1 denoted absence of artefacts and 4 major artefacts requiring repetition in a clinical setting. A lack of STIR fat suppression was commonly reported (16/26). Ordinal logistic regression showed no statistically significant differences in image quality between the negative control and either the non-Tafonius or the Tafonius groups (P = 0.535 and P = 0.881, respectively), and with the use of Tafonius compared to the other anaesthetic machines (P = 0.578). The only statistically significant differences in scores were observed between the positive control and the non-Tafonius (P = 0.006) and the Tafonius groups (P = 0.017). Our findings suggest that anaesthetic machines and monitoring do not appear to affect MRI scan quality and support the use of Tafonius during acquisition of images with a 0.31T MRI system in a clinical context.


Assuntos
Anestesia , Anestésicos , Doenças dos Cavalos , Cavalos , Animais , Artefatos , Estudos Prospectivos , Imageamento por Ressonância Magnética/veterinária , Cadáver , Anestesia/veterinária
2.
Vet Radiol Ultrasound ; 50(5): 536-44, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19788041

RESUMO

Our aims were to evaluate the pattern of radiopharmaceutical uptake in horses with lameness related to the metacarpophalangeal and/or metatarsophalangeal joint and compare the results with similar information from sound horses. It was hypothesized bthat there would be a difference in radiopharmaceutical uptake between the lame and contralateral limb in unilaterally lame horses and that there would be a difference between lame and sound horses. Nuclear scintigraphic images of 43 horses with forelimb lameness and 30 horses with hindlimb lameness were evaluated. In all horses lameness was improved by intraarticular analgesia of the joint, or by perineural analgesia of the palmar/plantar (at the junction of the proximal 3/4 and the distal 1/4 of the metacarpal/metatarsal regions) and palmar/plantar metacarpal/metatarsal nerves. All images were assessed subjectively and a quantitative image analysis was performed by drawing a vertical line profile through the center of each joint in the lateral images and using region of interest analysis in both lateral and dorsal/plantar images. Ratios of radiopharmaceutical uptake were compared for each region between lame and contralateral limbs in unilaterally lame horses and between lame and control horses. There was a significant difference in the ratio of radiopharmaceutical uptake in the proximal aspect of the proximal phalanx between lame and nonlame forelimbs in unilaterally lame horses and in both lame and contralateral limbs of lame horses compared with control horses for the regions of the distal aspect of the third metacarpal/metatarsal bone and the proximal sesamoid bones. However, the profile analysis was of limited clinical value.


Assuntos
Artralgia/veterinária , Doenças dos Cavalos/diagnóstico por imagem , Coxeadura Animal/diagnóstico por imagem , Articulação Metacarpofalângica/diagnóstico por imagem , Articulação Metatarsofalângica/diagnóstico por imagem , Animais , Artralgia/diagnóstico por imagem , Cavalos , Cintilografia , Compostos Radiofarmacêuticos , Medronato de Tecnécio Tc 99m
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA