Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
JAMA Netw Open ; 7(4): e246548, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639939

RESUMO

Importance: Unintended tumor-positive resection margins occur frequently during minimally invasive surgery for colorectal liver metastases and potentially negatively influence oncologic outcomes. Objective: To assess whether indocyanine green (ICG)-fluorescence-guided surgery is associated with achieving a higher radical resection rate in minimally invasive colorectal liver metastasis surgery and to assess the accuracy of ICG fluorescence for predicting the resection margin status. Design, Setting, and Participants: The MIMIC (Minimally Invasive, Indocyanine-Guided Metastasectomy in Patients With Colorectal Liver Metastases) trial was designed as a prospective single-arm multicenter cohort study in 8 Dutch liver surgery centers. Patients were scheduled to undergo minimally invasive (laparoscopic or robot-assisted) resections of colorectal liver metastases between September 1, 2018, and June 30, 2021. Exposures: All patients received a single intravenous bolus of 10 mg of ICG 24 hours prior to surgery. During surgery, ICG-fluorescence imaging was used as an adjunct to ultrasonography and regular laparoscopy to guide and assess the resection margin in real time. The ICG-fluorescence imaging was performed during and after liver parenchymal transection to enable real-time assessment of the tumor margin. Absence of ICG fluorescence was favorable both during transection and in the tumor bed directly after resection. Main Outcomes and Measures: The primary outcome measure was the radical (R0) resection rate, defined by the percentage of colorectal liver metastases resected with at least a 1 mm distance between the tumor and resection plane. Secondary outcomes were the accuracy of ICG fluorescence in detecting margin-positive (R1; <1 mm margin) resections and the change in surgical management. Results: In total, 225 patients were enrolled, of whom 201 (116 [57.7%] male; median age, 65 [IQR, 57-72] years) with 316 histologically proven colorectal liver metastases were included in the final analysis. The overall R0 resection rate was 92.4%. Re-resection of ICG-fluorescent tissue in the resection cavity was associated with a 5.0% increase in the R0 percentage (from 87.4% to 92.4%; P < .001). The sensitivity and specificity for real-time resection margin assessment were 60% and 90%, respectively (area under the receiver operating characteristic curve, 0.751; 95% CI, 0.668-0.833), with a positive predictive value of 54% and a negative predictive value of 92%. After training and proctoring of the first procedures, participating centers that were new to the technique had a comparable false-positive rate for predicting R1 resections during the first 10 procedures (odds ratio, 1.36; 95% CI, 0.44-4.24). The ICG-fluorescence imaging was associated with changes in intraoperative surgical management in 56 (27.9%) of the patients. Conclusions and Relevance: In this multicenter prospective cohort study, ICG-fluorescence imaging was associated with an increased rate of tumor margin-negative resection and changes in surgical management in more than one-quarter of the patients. The absence of ICG fluorescence during liver parenchymal transection predicted an R0 resection with 92% accuracy. These results suggest that use of ICG fluorescence may provide real-time feedback of the tumor margin and a higher rate of complete oncologic resection.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Idoso , Feminino , Humanos , Masculino , Estudos de Coortes , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Verde de Indocianina , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Margens de Excisão , Imagem Óptica/métodos , Estudos Prospectivos , Pessoa de Meia-Idade
2.
Eur J Radiol ; 156: 110552, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36228455

RESUMO

PURPOSE: To assess the quantitative minimal ablation margin (MAM) in patients with colorectal liver metastases (CRLM) treated with percutaneous thermal ablation (TA) and correlate the quantitative MAM with local tumour recurrence (LTR). METHOD: Thirty-nine of 143 patients with solitary or multiple CRLM who underwent a first percutaneous TA procedure between January 2011 and May 2020 were considered eligible for study enrolment. Image fusion of pre- and post-ablation scans and 3D quantitative MAM assessment was performed using the in-house developed semi-automatic rigid MRI/CECT-CECT co-registration software deLIVERed. The quantitative MAM was analysed and correlated with LTR. RESULTS: Eighteen (46 %) patients were additionally excluded from further analyses due to suboptimal co-registration (quality co-registration score ≤ 3). The quality of co-registration was considered sufficient in 21 (54 %) patients with a total of 29 CRLM. LTR was found in 5 of 29 (17 %) TA-treated CRLM. In total, 12 (41 %) negative MAMs were measured (mean MAM -4.7 ± 2.7 mm). Negative MAMs were significantly more frequently seen in patients who developed LTR (100 %) compared to those without LTR (29 %; p = 0.003). The median MAM of patients who developed LTR (-6.6 mm (IQR -9.5 to -4.6)) was significantly smaller compared to the median MAM of patients without LTR (0.5 mm (IQR -1.8 to 3.0); p < 0.001). The ROC curve showed high accuracy in predicting LTR for the quantitative MAM (area under the curve of 0.975 ± 0.029). CONCLUSION: This study demonstrated the feasibility of 3D quantitative MAM assessment, using deLIVERed co-registration software, to assess technical success of TA in patients with CRLM and to predict LTR.


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Ablação por Cateter/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias Colorretais/patologia , Resultado do Tratamento , Estudos Retrospectivos
3.
Clin Cancer Res ; 26(15): 3990-3998, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32345649

RESUMO

PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.


Assuntos
Carcinoma/diagnóstico , Colo/diagnóstico por imagem , Neoplasias do Colo/diagnóstico , Corantes Fluorescentes/administração & dosagem , Imagem Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Carcinoma/patologia , Carcinoma/terapia , Quimiorradioterapia Adjuvante , Colectomia/métodos , Colo/patologia , Colo/cirurgia , Neoplasias do Colo/patologia , Neoplasias do Colo/terapia , Estudos de Viabilidade , Feminino , Corantes Fluorescentes/efeitos adversos , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacocinética , Voluntários Saudáveis , Humanos , Integrinas/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Terapia Neoadjuvante , Imagem Óptica/efeitos adversos , Peptídeos Cíclicos/administração & dosagem , Peptídeos Cíclicos/efeitos adversos , Peptídeos Cíclicos/química , Peptídeos Cíclicos/farmacocinética , Compostos de Amônio Quaternário/administração & dosagem , Compostos de Amônio Quaternário/efeitos adversos , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacocinética , Ratos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ácidos Sulfônicos/administração & dosagem , Ácidos Sulfônicos/efeitos adversos , Ácidos Sulfônicos/química , Ácidos Sulfônicos/farmacocinética , Testes de Toxicidade Aguda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA