Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-37838298

RESUMO

Modern studies have revealed gender and race-related disparities in the management and outcomes of cardiac arrhythmias, but few studies have focused on outcomes for ventricular arrhythmias (VAs) such as ventricular tachycardia (VT) or ventricular fibrillation (VF). The aim of this article is to review relevant studies and identify outcome differences in the management of VA among Black and female patients. We found that female patients typically present younger for VA, are more likely to have recurrent VA after catheter ablation, are less likely to be prescribed antiarrhythmic medication, and are less likely to receive primary prevention ICD placement as compared to male patients. Additionally, female patients appear to derive similar overall mortality benefit from primary prevention ICD placement as compared to male patients, but they may have an increased risk of acute post-procedural complications. We also found that Black patients presenting with VA are less likely to undergo catheter ablation, receive appropriate primary prevention ICD placement, and have significantly higher risk-adjusted 1-year mortality rates after hospital discharge as compared to White patients. Black female patients appear to have the worst outcomes out of any demographic subgroup.

2.
J Cardiovasc Electrophysiol ; 33(8): 1714-1722, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35652836

RESUMO

INTRODUCTION: Monitored anesthesia care (MAC) or general anesthesia (GA) can be used during catheter ablation (CA) of atrial fibrillation (AF). However, each approach may have advantages and disadvantages with variability in operator preferences. The optimal approach has not been well established. The purpose of this study was to compare procedural efficacy, safety, clinical outcomes, and cost of CA for AF performed with MAC versus GA. METHODS: The study population consisted of 810 consecutive patients (mean age: 63 ± 10 years, paroxysmal AF: 48%) who underwent a first CA for AF. All patients completed a preprocedural evaluation by the anesthesiologists. Among the 810 patients, MAC was used in 534 (66%) and GA in 276 (34%). Ten patients (1.5%) had to convert to GA during the CA. RESULTS: Although the total anesthesia care was longer with GA particularly in patients with persistent AF, CA was shorter by 5 min with GA than MAC (p < 0.01). Prevalence of perioperative complications was similar between the two groups (4% vs. 4%, p = 0.89). There was no atrioesophageal fistula with either approach. GA was associated with a small, ~7% increase in total charges due to longer anesthesia care. During 43 ± 17 months of follow-up after a single ablation procedure, 271/534 patients (51%) in the MAC and 129/276 (47%) patients in the GA groups were in sinus rhythm without concomitant antiarrhythmic drug therapy (p = 0.28). CONCLUSION: With the participation of an anesthesiologist, and proper preoperative assessment, CA of AF using GA or MAC has similar efficacy and safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Anestesia Geral/efeitos adversos , Antiarrítmicos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
3.
J Transl Med ; 19(1): 460, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34749739

RESUMO

BACKGROUND: Sarcoidosis is an inflammatory disease characterized by the formation of granulomas, which involve the heart in up to 25% of patients. Cardiac sarcoidosis can lead to life threatening arrhythmias and heart failure. While corticosteroids have been used as a treatment for over 50 years, they are associated with hypertension, diabetes, and weight gain, further increasing cardiovascular risk. Interleukin-1 (IL-1) is the prototypical proinflammatory cytokine that works to activate the nuclear transcription factor NF-kB, one of the targets of glucocorticoids. IL-1 also plays an important role also in the pathophysiology of heart disease including atherosclerosis, myocardial infarction, and myocarditis. METHODS: Building on a network of research collaborators developed in the Cardiac Sarcoidosis Consortium, we will investigate the feasibility and tolerability of treatment of CS with anakinra at two National Institute of Health Clinical and Translational Science Award (CTSA) hubs with expertise in cardiac sarcoidosis. In this pilot study, up to 28 patients with cardiac sarcoidosis will be recruited to compare the administration of an IL-1 blocker, anakinra, 100 mg daily on top of standard of care versus standard of care only for 28 days and followed for 180 days. Utilizing surrogate endpoints of changes in systemic inflammatory biomarkers and cardiac imaging, we aim to determine whether IL-1 blockade with anakinra can combat systemic and cardiac inflammation in patients with cardiac sarcoidosis. DISCUSSION: The current trial demonstrates an innovative collaborative approach to clinical trial development in a rare, understudied disease that disproportionately affects females and minorities. Trial Registration The trial was registered prospectively with ClinicalTrials.gov on July 12, 2019, identifier NCT04017936.


Assuntos
Miocardite , Sarcoidose , Feminino , Granuloma , Humanos , Proteína Antagonista do Receptor de Interleucina 1/uso terapêutico , Interleucina-1 , Projetos Piloto , Sarcoidose/complicações , Sarcoidose/tratamento farmacológico , Ciência Translacional Biomédica , Resultado do Tratamento
4.
AJR Am J Roentgenol ; 213(3): 555-561, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31120781

RESUMO

OBJECTIVE. An important application of late gadolinium enhancement (LGE) cardiac MRI is accurate assessment of myocardial scar before ablation. However, this is often limited in patients with cardiac implantable electronic devices (CIEDs) because of metal device-induced artifacts. The purpose of this study was to determine whether a modified wideband inversion recovery (IR) LGE MRI technique decreases artifact volume to allow the assessment of myocardial scar. SUBJECTS AND METHODS. Fifty patients (17 women and 33 men; mean age ± SD, 61 ± 12 years; mean ejection fraction ± SD, 35.9% ± 13.3%) with CIEDs underwent cardiac MRI using conventional and modified wideband IR LGE techniques before ablation. The volume of device-induced artifact was quantified and stratified by tertiles on mild, moderate, and severe. Ordinal logistic regression analysis assessed the association between artifact volume on conventional and wideband images adjusted for patients' demographics. RESULTS. Conventional LGE MRI resulted in device-induced hyperintense artifacts that obscured ventricular segments in 32 of 50 (64%) cases. Wideband LGE MRI significantly reduced severe artifact volume (p < 0.0001) and completely resolved all mild and most moderate artifacts. Overall, wideband techniques resulted in a 56% reduction in total artifact volume for the cohort (p < 0.0001). The wideband LGE MRI sequence minimized artifacts in the most commonly obscured segments on the conventional LGE MRI sequence, with persistent artifacts in seven, eight, and four of 32 cases at the basal anterior, midventricular anterior, and midventricular anteroseptal segments, respectively. CONCLUSION. The modified wideband IR technique completely resolves mild and moderate device-induced hyperintense artifacts and significantly reduces the volume of severe artifact to allow accurate identification of myocardial scar in patients with CIEDs before ablation.


Assuntos
Artefatos , Cicatriz/diagnóstico por imagem , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Marca-Passo Artificial , Meios de Contraste , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos
5.
World J Radiol ; 10(9): 100-107, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30310544

RESUMO

Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is the gold standard for imaging myocardial viability. An important application of LGE CMR is the assessment of the location and extent of the myocardial scar in patients with ventricular tachycardia (VT), which allows for more accurate identification of the ablation targets. However, a large percentage of patients with VT have cardiac implantable electronic devices (CIEDs), which is a relative contraindication for cardiac magnetic resonance imaging due to safety and image artifact concerns. Previous studies showed that these patients can be safely scanned on 1.5 T scanners provided that an adequate imaging protocol is adopted. Nevertheless, imaging patients with a CIED result in metal artifacts due to the strong frequency off-resonance effects near the device; therefore, the spins in the surrounding myocardium are not completely inverted, and thus give rise to hyperintensity artifacts. These artifacts obscure the myocardial scar tissue and limit the ability to study the correlation between the myocardial scar structure and the electro-anatomical map during catheter ablation. In this study, we developed a modified inversion recovery technique to alleviate the CIED-induced metal artifacts and improve the diagnostic image quality of LGE images in patients with CIEDs without increasing scan time or requiring additional hardware. The developed technique was tested in phantom experiments and in vivo scans, which showed its capability for suppressing the hyperintensity artifacts without compromising myocardium nulling in the resulting LGE images.

6.
J Cardiovasc Electrophysiol ; 29(2): 284-290, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29071765

RESUMO

INTRODUCTION: Although noninferiority of cryoballoon ablation (CBA) and radiofrequency catheter ablation for antral pulmonary vein isolation (APVI) has been reported in patients with paroxysmal atrial fibrillation (PAF), it is not clear whether contact force sensing (CF-RFA) and CBA with the second-generation catheter have similar procedural costs and long-term outcomes. The objective of this study is to compare the long-term efficacy and cost implications of CBA and CF-RFA in patients with PAF. METHODS AND RESULTS: A first APVI was performed in 146 consecutive patients (age: 63 ± 10 years, men: 95 [65%], left atrial diameter: 42 ± 6 mm) with PAF using CBA (71) or CF-RFA (75). Clinical outcomes and procedural costs were compared. The mean procedure time was significantly shorter with CBA than with CF-RFA (98 ± 39 vs. 158 ± 47 minutes, P < 0.0001). Despite a higher equipment cost in the CBA than the CF-RFA group, the total procedure cost was similar between the two groups (P = 0.26), primarily driven by a shorter procedure duration that resulted in a lower anesthesia cost. At 25 ± 5 months after a single ablation procedure, 51 patients (72%) in the CBA, and 55 patients (73%) in the CF-RFA groups remained free from atrial arrhythmias without antiarrhythmic drug therapy (P = 0.84). CONCLUSIONS: The procedure duration was approximately 60 minutes shorter with CBA than CF-RFA. The procedural costs were similar with both approaches. At 2 years after a single procedure, CBA and CF-RFA have similar single-procedure efficacies of 72-73%.


Assuntos
Fibrilação Atrial/economia , Fibrilação Atrial/cirurgia , Ablação por Cateter/economia , Criocirurgia/economia , Custos Hospitalares , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Anestesia/economia , Antiarrítmicos/economia , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Custos de Medicamentos , Técnicas Eletrofisiológicas Cardíacas/economia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Intervalo Livre de Progressão , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação/economia , Estudos Retrospectivos , Fatores de Tempo
8.
JACC Cardiovasc Imaging ; 3(3): 278-85, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20223425

RESUMO

OBJECTIVES: To identify and characterize ablation lesions after radiofrequency (RF) catheter ablation of ventricular arrhythmias in patients without prior myocardial infarction and to correlate the ablation lesions with the amount of RF energy delivered and the clinical outcome. BACKGROUND: Visualization of RF energy lesions after ablation of ventricular arrhythmias might help to identify reasons for ablation failure. METHODS: In a consecutive series of 35 patients (19 women, age: 48 +/- 15 years, ejection fraction: 0.56 +/- 0.12) without structural heart disease who were referred for ablation of ventricular arrhythmias, cardiac magnetic resonance imaging with delayed enhancement was performed before and after ablation. Ablation lesions were sought in the post-ablation cardiac magnetic resonance images. The endocardial area, depth, and volume of the lesions were measured. Lesion size was correlated with the type of ablation catheter used and the duration of RF energy delivered. RESULTS: In 25 of 35 patients (71%), ablation lesions were identified by delayed enhancement a mean of 22 +/- 12 months after the initial ablation procedure. The mean lesion volume was 1.4 +/- 1.4 cm(3), with a mean endocardial area of 3.5 +/- 3.0 cm(2). The largest lesions (mean volume of 2.9 +/- 2.1 cm(3) with an endocardial area of 6.4 +/- 3.4 cm(2)) were identified in patients in whom the arrhythmias originated in the papillary muscles. Ablation duration correlated with lesion size (r = 0.67, p < 0.001). There was no difference in lesion volume with irrigated versus nonirrigated ablation catheters (1.0 +/- 0.73 vs. 2.0 +/- 2.1 cm(3), p = 0.09). Identification of ablation lesions in patients with a failed procedure identified the sites where ineffective RF energy lesions were created. CONCLUSIONS: RF ablation lesions can be detected long term after an ablation procedure targeting ventricular arrhythmias in patients without previous infarction. Lesion size correlates with the amount of RF energy delivered and is largest when a targeted arrhythmia originates in a papillary muscle.


Assuntos
Ablação por Cateter , Imagem Cinética por Ressonância Magnética , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Adulto , Ablação por Cateter/instrumentação , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Gadolínio DTPA , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
9.
J Am Coll Cardiol ; 53(9): 782-9, 2009 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-19245970

RESUMO

OBJECTIVES: This study sought to determine whether ablation of complex fractionated atrial electrograms (CFAEs) after antral pulmonary vein isolation (APVI) further improves the clinical outcome of APVI in patients with long-lasting persistent atrial fibrillation (AF). BACKGROUND: Ablation of CFAEs has been reported to eliminate persistent AF. However, residual pulmonary vein arrhythmogenicity is a common mechanism of recurrence. METHODS: In this randomized study, 119 consecutive patients (mean age 60 +/- 9 years) with long-lasting persistent AF underwent APVI with an irrigated-tip radiofrequency ablation catheter. Antral pulmonary vein isolation resulted in termination of AF in 19 of 119 patients (Group A, 16%). The remaining 100 patients who still were in AF were randomized to no further ablation and underwent cardioversion (Group B, n = 50) or to ablation of CFAEs in the left atrium or coronary sinus for up to 2 additional hours of procedure duration (Group C, n = 50). RESULTS: Atrial fibrillation terminated during ablation of CFAEs in 9 of 50 patients (18%) in Group C. At 10 +/- 3 months after a single ablation procedure, 18 of 50 (36%) in Group B and 17 of 50 (34%) in Group C were in sinus rhythm without antiarrhythmic drugs (p = 0.84). In Group A, 15 of 19 patients (79%) were in sinus rhythm. A repeat ablation procedure was performed in 34 of 100 randomized patients (for AF in 30 and atrial flutter in 4). At 9 +/- 4 months after the final procedure, 34 of 50 (68%) in Group B and 30 of 50 (60%) in Group C were in sinus rhythm without antiarrhythmic drugs (p = 0.40). CONCLUSIONS: Up to 2 h of additional ablation of CFAEs after APVI does not appear to improve clinical outcomes in patients with long-lasting persistent AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Eletrofisiologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA