Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Microbiol Spectr ; 12(2): e0239723, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38189291

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic demonstrated the need for accurate diagnostic testing for the early detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Although the pandemic has ended, accurate assays are still needed to monitor viral spread at national levels and beyond through population and wastewater surveillance. To enhance early detection, SARS-CoV-2 assays should have high diagnostic accuracy and should be validated to assure accurate results. Three distinct SARS-CoV-2 assays were evaluated with clinical samples using the VALCOR (VALidation of SARS-CORona Virus-2 assays) framework, with the TaqPath COVID-19 assay (ThermoFisher Scientific, USA) as a comparator. We evaluated clinical sensitivity, specificity, limit of detection (LOD), and overall concordance between comparator and three index Allplex SARS-CoV-2 assays (Seegene, South Korea): Allplex-SC2, Allplex-SC2Fast (Fast PCR), and Allplex-SC2FabR (SARS-CoV-2/FluA/FluB/respiratory syncytial virus). Analytical performance and LOD of index assays were assessed using a dilution series of three synthetic SARS-CoV-2 sequence reference materials (RMs). Ninety SARS-CoV-2 positives and 90 SARS-CoV-2 negatives were tested. All Allplex assays had 100.0% sensitivity (95%CI = 95.9%-100.0%). Allplex-SC2 and Allplex-SC2Fast assays had 97.8% specificity (95%CI = 92.3%-99.7%) and 98.9% overall concordance [κ = 0.978 (95%CI = 0.947-1.000)]. Allplex-SC2FabR assay showed 100.0% specificity (95%CI = 95.9%-100.0%) and 100.0% overall concordance [κ = 1.000 (95%CI = 1.000-1.000)]. LOD assessment of index assays revealed detection down to 2.61 × 102 copies/mL in clinical samples, while the analytical LOD was 9.00 × 102 copies/mL. In conclusion, the evaluation of the three Seegene Allplex SARS-CoV-2 assays showed high sensitivity and specificity and an overall good assay concordance with the comparator. The assays showed low analytical LOD using RM and even a slightly lower LOD in clinical samples. Non-overlapping target gene sequences between SARS-CoV-2 assays and RMs emphasize the need for aligning targeted sequences of diagnostic assays and RMs.IMPORTANCEThe coronavirus disease 2019 pandemic has a significant impact on global public health, economies, and societies. As shown through the first phases of the pandemic, accurate and timely diagnosis is crucial for disease control, prevention, and monitoring. Though the pandemic phase of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has concluded, diagnostic assays remain in demand to monitor SARS-CoV-2 at the individual patient level, regionally, and nationally, as well as to remain an infectious disease preparedness instrument to monitor any new SARS-CoV-2 dissemination across borders using population and wastewater surveillance. The anticipation by WHO and central health care policy entities such as the Center for Disease Control, EMA, and multiple national health authorities is that SARS-CoV-2 will reside as an endemic respiratory disease for years to come. The key strategic consideration is hence shifting from combating a pandemic situation with a high number of patients to instead allowing precise diagnostics of suspected patients with the intention of correct management in a low-prevalence setting.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Águas Residuárias , Sensibilidade e Especificidade , Vigilância Epidemiológica Baseada em Águas Residuárias
2.
Virol J ; 20(1): 35, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36829164

RESUMO

BACKGROUND: The COVID-19 pandemic highlighted the importance of diagnostic testing against curbing the spread of SARS-CoV-2. The urgent need and scale for diagnostic tools resulted in manufacturers of SARS-CoV-2 assays receiving emergency authorization that lacked robust analytical or clinical evaluation. As it is highly likely that testing for SARS-CoV-2 will continue to play a central role in public health, the performance characteristics of assays should be evaluated to ensure reliable diagnostic outcomes are achieved. METHODS: VALCOR or "VALidation of SARS-CORona Virus-2 assays" is a study protocol designed to set up a framework for test validation of SARS-CoV-2 virus assays. Using clinical samples collated from VALCOR, the performance of Aptima SARS-CoV-2 assay was assessed against a standard comparator assay. Diagnostic test parameters such as sensitivity, specificity and overall per cent agreement were calculated for the clinical performance of Aptima SARS-CoV-2 assay. RESULTS: A total of 180 clinical samples were tested with an addition of 40 diluted clinical specimens to determine the limit of detection. When compared to the standard comparator assay Aptima had a sensitivity of 100.0% [95% CI 95.9-100.0] and specificity of 96.7% [95% CI 90.8-99.3]. The overall percent agreement was 98.3% with an excellent Cohen's coefficient of κ = 0.967 [95% CI 0.929-1.000]. For the limit of detection, Aptima was able to detect all of the diluted clinical samples. CONCLUSION: In conclusion. validation of Aptima SARS-CoV-2 assay using clinical samples collated through the VALCOR protocol showed excellent test performance. Additionally, Aptima demonstrated high analytical sensitivity by detecting all diluted clinical samples corresponding to a low limit of detection.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Técnicas de Laboratório Clínico/métodos , Teste para COVID-19 , Técnicas de Diagnóstico Molecular/métodos , Pandemias , Sensibilidade e Especificidade
3.
J Clin Pathol ; 76(3): 172-176, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34782423

RESUMO

AIM: The Papilloplex high-risk human papillomavirus (hrHPV) test (Genefirst, Oxford, UK) is a single tube real-time HPV test which provides multiplex detection and separate identification of 14 hrHPV types. Here, we present the clinical validation of the test in SurePath samples in comparison to a clinically validated reference test, the GP5+/6+Enzyme ImmunoAssay (GP5+/6+EIA) using the VALGENT (VALidation of HPV GENotyping Tests) framework. METHODS: Clinical performance was assessed using 998 unselected, cervical screening samples enriched with 297 cytologically abnormal specimens (100 atypical squamous cells of unspecified significance, 100 low-grade squamous intraepithelial lesions, 97 high-grade squamous intraepithelial lesions). Cases were defined as women diagnosed with histologically confirmed cervical intraepithelial neoplasia two or more (≥CIN2, N=119) and controls defined as women with two subsequent negative cytology results (N=834). RESULTS: The Papilloplex HR-HPV test has non-inferior sensitivity for detection of cervical precancer (p=0.0001 for ≥CIN2 and p=0.0005 for ≥CIN3) and non-inferior specificity, compared with GP5+/6+EIA (pni=0.0167)). The assay also showed excellent or good agreement for overall hrHPV and nearly all individual HPV types as compared with GP5+/6+EIA/Luminex. CONCLUSION: The Papilloplex HR-HPV applied on cervical specimens stored in SurePath medium fulfils the international clinical accuracy criteria for use in cervical cancer screening.


Assuntos
Infecções por Papillomavirus , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/patologia , Detecção Precoce de Câncer/métodos , Papillomavirus Humano , Infecções por Papillomavirus/diagnóstico , Sensibilidade e Especificidade , Papillomaviridae/genética , Displasia do Colo do Útero/diagnóstico
4.
J Low Genit Tract Dis ; 25(1): 27-37, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33105450

RESUMO

OBJECTIVE: The aim of the study was to examine whether high-grade cervical intraepithelial neoplasia (CIN) was more closely associated with human papillomavirus (HPV) same-genotype persistence (SGTP) versus clearance of prior infection with a subsequent infection by a new genotype (genotype switch [GS]), clearance of HPV infection, or acquisition of a new HPV infection after a negative infection status, during a follow-up testing subsequent to abnormal screening results. MATERIALS AND METHODS: MEDLINE, Cochrane Library, Health Technology Assessment, and clinicaltrials.gov were searched from January 2000 to July 2019 for prospective controlled trials and observational studies of women and retrospective studies using HPV assays with extended- or full-genotype reporting. The primary outcome was high-grade CIN after at least 2 rounds of testing. Overall quality of evidence for the risk estimate outcomes was assessed. Of the 830 identified abstracts, 66 full-text articles were reviewed, and 7 studies were included in the synthesis. The study protocol was registered with the PROSPERO International Prospective Register of Systematic Reviews (CRD42018091093). RESULTS: Continued HPV-positive women falls in 2 equally large groups: SGTP and GS. Sensitivity, positive predictive value, and positive likelihood ratio of SGTP were significantly higher than for GS. Human papillomavirus genotypes may be ranked into 3 tiers (immediate colposcopy, follow-up testing, return to routine screening), according to associated risk of persistence for high-grade CIN and to prevailing clinical action thresholds. CONCLUSIONS: There is moderately high-quality evidence to support the clinical utility of SGTP to improve risk discrimination for high-grade CIN compared with qualitative HPV testing without genotype-specific information.


Assuntos
Papillomaviridae/genética , Infecções por Papillomavirus/epidemiologia , Infecções por Papillomavirus/genética , Displasia do Colo do Útero/virologia , Neoplasias do Colo do Útero/virologia , Adulto , Colposcopia , Detecção Precoce de Câncer/métodos , Feminino , Genótipo , Humanos , Metanálise como Assunto , Pessoa de Meia-Idade , Papillomaviridae/isolamento & purificação , Fatores de Risco , Neoplasias do Colo do Útero/genética , Neoplasias do Colo do Útero/patologia , Adulto Jovem , Displasia do Colo do Útero/genética , Displasia do Colo do Útero/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA