1.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37684141

RESUMO

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Assuntos
Cimentos Dentários , Implantes Dentários , Cimentos Dentários/química , Titânio/química , Coroas , Zircônio/química , Teste de Materiais , Dente Suporte , Análise do Estresse Dentário
2.
J Oral Maxillofac Surg ; 76(1): 71-79, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28893541

RESUMO

PURPOSE: This work evaluated the nanomechanical properties of bone surrounding submerged and immediately loaded implants after 3 years in vivo. It was hypothesized that the nanomechanical properties of bone would markedly increase in immediately and functionally loaded implants compared with submerged implants. MATERIALS AND METHODS: The second, third, and fourth right premolars and the first molar of 10 adult Doberman dogs were extracted. After 6 months, 4 implants were placed in 1 side of the mandible. The mesial implant received a cover screw and remained unloaded. The remaining 3 implants received fixed dental prostheses within 48 hours after surgery that remained in occlusal function for 3 years. After sacrifice, the bone was prepared for histologic and nanoindentation analysis. Nanoindentation was carried out under wet conditions on bone areas within the plateaus. Indentations (n = 30 per histologic section) were performed with a maximum load of 300 µN (loading rate, 60 µN per second) followed by a holding and unloading time of 10 and 2 seconds, respectively. Elastic modulus (E) and hardness (H) were computed in giga-pascals. The amount of bone-to-implant contact (BIC) also was evaluated. RESULTS: The E and H values for cortical bone regions were higher than those for trabecular bone regardless of load condition, but this difference was not statistically significant (P > .05). The E and H values were higher for loaded implants than for submerged implants (P < .05) for cortical and trabecular bone. For the same load condition, the E and H values for cortical and trabecular bone were not statistically different (P > .05). The loaded and submerged implants presented BIC values (mean ± standard deviation) of 57.4 ± 12.1% and 62 ± 7.5%, respectively (P > .05). CONCLUSION: The E and H values of bone surrounding dental implants, measured by nanoindentation, were higher for immediately loaded than for submerged implants.


Assuntos
Processo Alveolar/ultraestrutura , Implantação Dentária Endóssea/métodos , Implantes Dentários , Mandíbula/cirurgia , Animais , Dente Pré-Molar , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Cães , Implantes Experimentais , Dente Molar
3.
Biomed Res Int ; 2015: 761718, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26090443

RESUMO

This study assessed the osseointegrative effects of atmospheric pressure plasma (APP) surface treatment for implants in a canine model. Control surfaces were untreated textured titanium (Ti) and calcium phosphate (CaP). Experimental surfaces were their 80-second air-based APP-treated counterparts. Physicochemical characterization was performed to assess topography, surface energy, and chemical composition. One implant from each control and experimental group (four in total) was placed in one radius of each of the seven male beagles for three weeks, and one implant from each group was placed in the contralateral radius for six weeks. After sacrifice, bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were assessed. X-ray photoelectron spectroscopy showed decreased surface levels of carbon and increased Ti and oxygen, and calcium and oxygen, posttreatment for Ti and CaP surfaces, respectively. There was a significant (P < 0.001) increase in BIC for APP-treated textured Ti surfaces at six weeks but not at three weeks or for CaP surfaces. There were no significant (P = 0.57) differences for BAFO between treated and untreated surfaces for either material at either time point. This suggests that air-based APP surface treatment may improve osseointegration of textured Ti surfaces but not CaP surfaces. Studies optimizing APP parameters and applications are warranted.


Assuntos
Pressão Atmosférica , Implantes Dentários , Osseointegração/fisiologia , Animais , Fosfatos de Cálcio/química , Materiais Revestidos Biocompatíveis/química , Cães , Humanos , Masculino , Propriedades de Superfície , Titânio/química
4.
J Biomed Mater Res B Appl Biomater ; 103(4): 798-806, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25115608

RESUMO

OBJECTIVES: The aim of this study was to quantify the polymerization volumetric shrinkage of one regular and two low shrinkage bulk fill composites in class I cavities with or without an adhesive layer, using three-dimensional (3D) micro-computed tomography (µCT). METHODS: Class I cavity preparations (2.5 mm depth × 4 mm length × 4 mm wide) were standardized in 36 extracted human third molars, which were randomly divided in six groups (n = 6 each) as follows: Group VIT (regular composite without bonding agent); Group SDR (low shrinkage flowable composite without bonding agent); Group TET (low shrinkage composite without bonding agent); Group VIT/P (regular composite with bonding agent); Group SDR/X (low shrinkage flowable composite with bonding agent); TET/T (low shrinkage composite with bonding agent). Each tooth was scanned via µCT at cavity preparation, immediately after cavity filling, and after light-curing. Acquired µCT data were imported into Amira software for analysis and volume values evaluated between steps from cavity preparation until light-curing. RESULTS: Both low shrinkage composites showed a significantly less volumetric shrinkage than VIT. The use of dental adhesive significantly decreased the average volumetric contraction similarly for the three composites, by about 20%. CONCLUSION: Both low shrinkage composites showed less volumetric polymerization contraction than the regular composite. The use of dental adhesive decreased the total volumetric shrinkage for all evaluated composites.


Assuntos
Resinas Acrílicas/química , Resinas Compostas/química , Preparo da Cavidade Dentária , Teste de Materiais/métodos , Poliuretanos/química , Microtomografia por Raio-X
5.
J Biomed Mater Res A ; 101(1): 98-103, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22826209

RESUMO

This study investigated the effect of an Argon-based nonthermal plasma (NTP) surface treatment-operated chairside at atmospheric pressure conditions applied immediately prior to dental implant placement in a canine model. Surfaces investigated comprised: Calcium-Phosphate (CaP) and CaP + NTP (CaP-Plasma). Surface energy was characterized by the Owens-Wendt-Rabel-Kaelble method and chemistry by X-ray photoelectron spectroscopy (XPS). Six adult beagles dogs received 2 plateau-root form implants (n = 1 each surface) in each radii, providing implants that remained 1 and 3 weeks in vivo. Histometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed by Kruskall-Wallis (95% level of significance) and Dunn's post-hoc test. The XPS analysis showed peaks of Ca, C, O, and P for the CaP and CaP-Plasma surfaces. Both surfaces presented carbon primarily as hydrocarbon (C-C, C-H) with lower levels of oxidized carbon forms. The CaP surface presented atomic percent values of 38, 42, 11, and 7 for C, O, Ca, and P, respectively, and the CaP-Plasma presented increases in O, Ca, and P atomic percent levels at 53, 12, and 13, respectively, in addition to a decrease in C content at 18 atomic percent. At 1 week no difference was found in histometric parameters between groups. At 3 weeks significantly higher BIC and BAFO were observed for CaP-Plasma treated surfaces. Surface elemental chemistry was modified by the Ar-based NTP. Ar-based NTP improved bone formation around plateau-root form implants at 3 weeks compared with CaP treatment alone.


Assuntos
Argônio/farmacologia , Fosfatos de Cálcio/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Implantes Dentários , Implantes Experimentais , Osseointegração/efeitos dos fármacos , Gases em Plasma/farmacologia , Animais , Cães , Masculino , Microscopia Eletrônica de Varredura , Osteogênese/efeitos dos fármacos
6.
Dent Mater ; 24(4): 483-91, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17675147

RESUMO

OBJECTIVES: To test the null hypothesis that continuity of resin cement/dentin interfaces is not affected by location along the root canal walls or water storage for 3 months when bonding fiber posts into root canals. METHODS: Fiber posts were luted to bovine incisors using four resinous luting systems: Multilink, Variolink II, Enforce Dual and Enforce PV. After cementation, roots were longitudinally sectioned and epoxy resin replicas were prepared for SEM analysis (baseline). The original halves were immersed in solvent, replicated and evaluated. After 3 months water storage and a second solvent immersion, a new set of replicas were made and analyzed. The ratio (%) between the length (mm) of available bonding interface and the actual extension of bonded cement/dentin interface was calculated. RESULTS: Significant lower percent values of bond integrity were found for Multilink (8.25%) and Variolink II (10.08%) when compared to Enforce Dual (25.11%) and Enforce PV (27.0%) at baseline analysis. The same trend was observed after immersion in solvent, with no significant changes. However, bond integrity was significantly reduced after 3 months water storage and a second solvent immersion to values below 5% (Multilink=3.31%, Variolink=1.87%, Enforce Dual=1.20%, and Enforce PV=0.75%). The majority of gaps were depicted at the apical and middle thirds at baseline and after immersion in solvent. After 3 months, gaps were also detected at the cervical third. SIGNIFICANCE: Bond integrity at the cement/dentin interface was surprisingly low after cementation of fiber posts to root canals with all resin cements. That was not significantly altered after immersion in solvent, but was further compromised after 3 months water storage. Gaps were mainly seen at middle and apical thirds throughout the experiment and extended to the cervical third after water storage for 3 months. Bond integrity of fiber posts luted to root canals was affected both by location and water storage.


Assuntos
Resinas Compostas , Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos de Resina , Animais , Bovinos , Análise Custo-Benefício , Retenção em Prótese Dentária , Cavidade Pulpar , Análise do Estresse Dentário , Dentina , Armazenamento de Medicamentos , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular/economia , Água
SELEÇÃO DE REFERÊNCIAS