Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Biomed Signal Process Control ; 65: 102339, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34168684

RESUMO

Impedance pneumography (ImP) is widely used for respiratory rate (RR) monitoring. However, ImP-derived RRs can be imprecise. The aim of this study was to develop a signal quality index (SQI) for the ImP signal, and couple it with a RR algorithm, to improve RR monitoring. An SQI was designed which identifies candidate breaths and assesses signal quality using: the variation in detected breath durations, how well peaks and troughs are defined, and the similarity of breath morphologies. The SQI categorises 32 s signal segments as either high or low quality. Its performance was evaluated using two critical care datasets. RRs were estimated from high-quality segments using a RR algorithm, and compared with reference RRs derived from manual annotations. The SQI had a sensitivity of 77.7 %, and specificity of 82.3 %. RRs estimated from segments classified as high quality were accurate and precise, with mean absolute errors of 0.21 and 0.40 breaths per minute (bpm) on the two datasets. Clinical monitor RRs were significantly less precise. The SQI classified 34.9 % of real-world data as high quality. In conclusion, the proposed SQI accurately identifies high-quality segments, and RRs estimated from those segments are precise enough for clinical decision making. This SQI may improve RR monitoring in critical care. Further work should assess it with wearable sensor data.

2.
BMC Med Inform Decis Mak ; 20(1): 161, 2020 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-32677936

RESUMO

BACKGROUND: Delay in identifying deterioration in hospitalised patients is associated with delayed admission to an intensive care unit (ICU) and poor outcomes. For the HAVEN project (HICF ref.: HICF-R9-524), we have developed a mathematical model that identifies deterioration in hospitalised patients in real time and facilitates the intervention of an ICU outreach team. This paper describes the system that has been designed to implement the model. We have used innovative technologies such as Portable Format for Analytics (PFA) and Open Services Gateway initiative (OSGi) to define the predictive statistical model and implement the system respectively for greater configurability, reliability, and availability. RESULTS: The HAVEN system has been deployed as part of a research project in the Oxford University Hospitals NHS Foundation Trust. The system has so far processed > 164,000 vital signs observations and > 68,000 laboratory results for > 12,500 patients and the algorithm generated score is being evaluated to review patients who are under consideration for transfer to ICU. No clinical decisions are being made based on output from the system. The HAVEN score has been computed using a PFA model for all these patients. The intent is that this score will be displayed on a graphical user interface for clinician review and response. CONCLUSIONS: The system uses a configurable PFA model to compute the HAVEN score which makes the system easily upgradable in terms of enhancing systems' predictive capability. Further system enhancements are planned to handle new data sources and additional management screens.


Assuntos
Cuidados Críticos , Unidades de Terapia Intensiva , Humanos , Pacientes , Reprodutibilidade dos Testes , Medição de Risco , Tempo
3.
Physiol Meas ; 37(4): 610-26, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27027672

RESUMO

Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of -4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and -5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of -5.6 to 5.2 bpm and a bias of -0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available.


Assuntos
Algoritmos , Eletrocardiografia , Fotopletismografia , Taxa Respiratória , Processamento de Sinais Assistido por Computador , Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
4.
BMC Med Inform Decis Mak ; 16: 19, 2016 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-26860362

RESUMO

BACKGROUND: An Early Warning Score is a clinical risk score based upon vital signs intended to aid recognition of patients in need of urgent medical attention. The use of an escalation of care policy based upon an Early Warning Score is mandated as the standard of practice in British hospitals. Electronic systems for recording vital sign observations and Early Warning Score calculation offer theoretical benefits over paper-based systems. However, the evidence for their clinical benefit is limited. Previous studies have shown inconsistent results. The majority have employed a "before and after" study design, which may be strongly confounded by simultaneously occurring events. This study aims to examine how the implementation of an electronic early warning score system, System for Notification and Documentation (SEND), affects the recognition of clinical deterioration occurring in hospitalised adult patients. METHODS: This study is a non-randomised stepped wedge evaluation carried out across the four hospitals of the Oxford University Hospitals NHS Trust, comparing charting on paper and charting using SEND. We assume that more frequent monitoring of acutely ill patients is associated with better recognition of patient deterioration. The primary outcome measure is the time between a patient's first observations set with an Early Warning Score above the alerting threshold and their subsequent set of observations. Secondary outcome measures are in-hospital mortality, cardiac arrest and Intensive Care admission rates, hospital length of stay and system usability measured using the System Usability Scale. We will also measure Intensive Care length of stay, Intensive Care mortality, Acute Physiology and Chronic Health Evaluation (APACHE) II acute physiology score on admission, to examine whether the introduction of SEND has any effect on Intensive Care-related outcomes. DISCUSSION: The development of this protocol has been informed by guidance from the Agency for Healthcare Research and Quality (AHRQ) Health Information Technology Evaluation Toolkit and Delone and McLeans's Model of Information System Success. Our chosen trial design, a stepped wedge study, is well suited to the study of a phased roll out. The choice of primary endpoint is challenging. We have selected the time from the first triggering observation set to the subsequent observation set. This has the benefit of being easy to measure on both paper and electronic charting and having a straightforward interpretation. We have collected qualitative measures of system quality via a user questionnaire and organisational descriptors to help readers understand the context in which SEND has been implemented.


Assuntos
Cuidados Críticos/métodos , Progressão da Doença , Indicadores Básicos de Saúde , Monitorização Fisiológica/métodos , Avaliação de Resultados em Cuidados de Saúde , Humanos , Risco , Medicina Estatal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA